![SAFERA PCU6.3-F Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/safera/pcu6-3-f/pcu6-3-f_user-and-installation-manual_3332718025.webp)
25
9. Troubleshooting
Press the OK button to find out the problem type. The indicator light
❹
:
Flashes in blue
Flashes in yellow
Once: Problem with wireless connection
between the sensor unit
Ⓐ
and the power
control unit
Ⓑ
.
Remedy: Manually pair the sensor unit with
the power control unit with the Safera App,
see chapter 5.
Once: Problem with sensors.
Twice: Problem with the power control unit
Ⓑ
.
Twice: Problem with sensor unit
Ⓐ
electronics or software.
Three times: power control unit
Ⓑ
over-
heating or other malfunction.
Three times: Faulty installation position of
the sensor unit
Ⓐ
: see remedy on the table
below.
No flash or sound.
Remedy: Replace the batteries, see chapter
7.3.
Problem
Remedy
Faulty installation
position of the
sensor unit
Ⓐ
.
Sensor unit
Ⓐ
has detected that it is not installed on a level surface,
pointing directly at the stove.
If mounted under cooker hood, check that the cooker hood bottom
surface is perfectly level.
Also check that the sensor distance from the stove is within the
limitations of chapter 4.4.
The appliance
repeatedly gives
false alarms
Test the working order according to chapter 4.6. If the product is in
working order, but gives repeatedly false alarms, re-run the "Installation
Wizard" in the Safera App to make sure that all kitchen and cooker
related parameters are correct.