1.

 

power

 

Connect the Household power,

 

Turn on the power switch, Green light

 

2.

 

battery  recovery   

if  the  battery  voltage  is  too  low,  Yellow  light  indicatior  flas

h,  first  to  recovery-charging(Max  Amp  1A),  it  will  last  for  one  hour,if  the  battery
  voltage  can  be  recovered  to  be  above  8.5V(12V  battery),  4.5V(6V  battery),  the
  charging  light  will  turn  on,  recovery  light  will  be  off,  recovery-charging  will  turn
  to  normal  charging.  If  it  can  not  be  recovered  to  normal  voltage,  dead  battery 
red  light  will  be  on,  recovery  light  will  be  off.

 

 

3.

 

charging   

When charging, yellow light will be on 

4.

 

charged 

When charged, green light will be on, disconncet the battery connection, light will 

be off.   

5.

  wrong  connectlon

  when  the 

Red/black  clamp  is  circuit  short  or  the  battery  is 

connected reversely, or the charger is connected to 12V battery under the condition of 6V, red 
light will flash. 

6.

  overload   

If the internal temperature is above 80

, the red light will be on, it can be 

charged, if above 100

, the output will be cut, charging light will be off, this red light will 

be on.

 

7.

 

dead battery 

If the battery can not reach the preset voltage

 above 8.5V(12V battery), 

4.5V(6V battery),

 after 1 hour recovery, the recovery will stop

red light will be on to 

judge it as a dead battery. 

 
Warning: 

When  charging,  according  to  the  battery  voltage,  select  the  charger  charging 

voltage,  so  that  the  charger  output  voltage  to  meet  the  requirements  of  the  battery 
requirements, so as not to use the wrong voltage charge battery

 

 
Ammeter  display  battery  status 

 

  The ammeter indicates the battery capacity by the percentage of battery capacity. 

0 -6A Charging current be appropriate for 6-75 AH 

Lead-acid   

battery 

Charging Procession 

Connect the battery charger to the mains power (120V AC): 

Connecting 120V AC power supply, the power LED will indicate. If the output is in a short-circuit 
situation, the LED will indicate “Fault”

,

, please solve the problem. 

Connecting the battery charger to your Battery 

Connect the red clamp from the charger to the positive (+) battery terminal. The Black clamp from the 
charger to the negative (-

) battery terminal. (The “Fault” LED will indicate if output reverse polarity 

connection, please re-connect ) 

Start the charging 

Connect AC plug to 120V power correctly, Select charging voltage 6v or 12v battery (If you are not 
sure the battery type pl

ease read the battery’s rating label first). Then connect both of clamps with 

battery terminals, turn on the power switch and began charging, final select appropriate current. 

Floating charging function 

Содержание BTC-1004A

Страница 1: ...ed or damaged 4 Never attempt to charge a damaged battery frozen battery or non rechargeable battery 5 Do not use the charger in a closed area or poorly ventilated area 6 The battery charger should be away from any heat source or ignitable air which would possibly cause explosion 7 Don t replace the cord and plug 8 If battery charger does not work properly don t repair it on your own otherwise it ...

Страница 2: ... have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved children shall not play with the appliance cleaning and user maintenance shall not be made by children without supervision 18 If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 19...

Страница 3: ...condition The LED will indicate the charging condition when charging Charging current switch When charging the battery according to the battery capacity refer to the battery charging current can be recommended in the specification the current selection switch to select suitable battery charging current charging current can not exceed the maximum current of the battery so as not to damage the charg...

Страница 4: ...V battery after 1 hour recovery the recovery will stop red light will be on to judge it as a dead battery Warning When charging according to the battery voltage select the charger charging voltage so that the charger output voltage to meet the requirements of the battery requirements so as not to use the wrong voltage charge battery Ammeter display battery status The ammeter indicates the battery ...

Страница 5: ... not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact you local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances wit...

Отзывы: