background image

Timelock: Adjust opening periods (Master Only) 

 

Opening  periods  are  occasions  when  the  safe  would 
normally  have  timelock  active,  but  is  required  to  be 
accessible.  E.g.  the  lock  would  normally  have  timelock 
active on Sundays, but an opening period is required for 
a special event. 

 

Follow the same instruc

tions for ‘Adjust closing periods’, 

but  scroll  to  OPENING  PERIODS  SETTING  to  adjust 
values.

 

 

Manager management (Master Only) 

 

Access  the  Master  menu,  scroll  to  MANAGER 

MANAGEMENT. Press 

 to accept.  

Press 1 to select the Manager, press 

to accept 

Press 

 

to  scroll  through  options  and  follow  the 

onscreen instructions to INSTALL, DELETE, DISABLED 
or ENABLE the Manager. 

 

Configuration User options 

 

 

Press 

  to  access  the  main  menu,  then  scroll  to 

CONFIGURATON. Enter the Configuration code, which 
is 505050 by default, and cannot be changed.  

 

The Configuration user can: 

 

  Install  and  remove  locks.  This  is  an  engineer 

function only and also requires the Master code. 

  Adjust the display contrast 

  Change the language 

  Test all the keys are working 

  View the Keypad firmware version 

 

Troubleshooting 

 

Display message: LOCK PENALTY  

An  incorrect  code  has  been  entered  4  times.  Wait  for  the  penalty 
period of 4 minutes to elapse before entering a valid code. 

 

Display message: BATTERY LOW 

The  batteries  must  be  replaced  immediately.  TechMaster  is  usually 
powered  with  a  battery  box  mounted  inside the  safe  or  vault.  Please 
consult  the  safe  or  vault  supplier  for  more  information  on  changing 
batteries. TechMaster can also be powered in an emergency using a 
9v alkaline battery from the slot at the bottom of the keypad. Unscrew 
the  security  screw  if  fitted,  pull  the  handle  of  the  battery  cover  and 
connect the battery to the battery connector located inside the slot. 

 

Display message: NO ANSWER 

There is a connection fault between the keypad and the lock. Contact 
a safe engineer. 

 

The display is not functioning 

See BATTERY LOW, the batteries should be replaced 

A key does not beep when pressed 

Undertake a keypad test. Press and hold 5. 
Press  each  key 

in  the order

  that  appears  on  the  screen  so  that  the 

digit/symbol disappears.  
Keys functioning normally will sound a short beep. If the key is faulty, 
the message WRONG/FAULTY KEY shows on the display. Contact a 
safe engineer. 

 

The safe or vault door does not open 

If  the  lock  system  is  otherwise  operating  normally,  there  is  a 
mechanical fault. Contact a safe engineer. 

Optional Features 

 

TechMaster  as  standard  is  programmed  with  the 
features  listed  in  these  instructions.  On  occasion  the 
specification may vary with the following features: 

 

Audit user: 

The Master and Manager are unable to access audit features. Instead, an 

Audit user is installed with a default code of 99-999999. Press   to access the main 
menu  then  scroll  to  AUDIT  CODE.  Select  either  PC  LINK  to  download  or  SYSTEM 
AUDIT to access the audit viewer.

 

 

Blocked  users: 

Some  or  all  of  the  Users  02-90  may  have  been  blocked  for  use,  in 

which case the ID(s) will not be available in USERS MANAGEMENT.

 

 

Dallas  Keys: 

Some  or  all  of  the  Users  02-90  and  possibly  the  Manager  must  touch 

their  Dallas  key  to  the  reader  on  the  side  of  the  keypad  in  addition  to  entering  their 
code.

 

 

To  open  the  lock: 

Press  any  key  to  wake  the  display  or  touch  the  Dallas  key  to  the 

reader

Touch  the  Dallas  key  to  the  reader,  the  display  will  show  either  the  User  ID 

XXXXXX or MANAGER CODE XXXXXX

Enter the 6-digit code, the lock will open. 

 

To  access  Manager  functions:

  Press  and  hold  6  to  access  the  Manager  menu,  and 

enter  the  6-digit  Manager  code.  The  display  shows  ENTER  MANAGER  DALLAS, 
touch the Manager Dallas Key to the reader, the menu options become available. 

 

To  install  new  Users:

  Follow  the  procedure  to  install  new  users.  After  the  new  code 

has  been  entered  twice,  the  display  shows  ENTER  USER  DALLAS,  touch  a  blank 
Dallas key to the reader. The programmed key must then always be used for that User 
ID and cannot be assigned to another User ID, even if the User is deleted. If a User ID 
is deleted, the originally programmed key can be used again for that ID if a new code 
is installed. If a key is lost, the User must be deleted and a new blank key can be used 
to reinstall the User. 

 

Note on using Dallas keys: Occasionally the contact between the Dallas key and 
reader is poor and the message ERROR IN READING DALLAS shows. Vary the 
position of the Dallas key to resolve. 

 

Dual  mode (standard): 

Two valid codes are required to open the lock. Users 02-90 

may  open  the  lock  in  dual  combination  either  with  another  User  02-90  or  with  the 
manager.  If  a  Manager  code  is  entered  first,  the  display  requests  a  user  code.  If  a 
User 02-90 code is entered first, the display requests the Manager code, press 

 to 

enter  another  User  code.  If  time  delay  is  active,  1  code  can  start  the  time  delay,  2 
codes are required to open during the open window.

 

 

A 2

nd

 code is also required for the Manager to access the Manager menu. There are 

no dual mode restrictions for the Master.  

 

User  02  is  installed  with  a  default  code  of  02-020202.  If  only  one  User  02-90  is 
installed, do not allow that User to be deleted without first adding another User 
or the Manager will be unable to access the Manager menu. 

 

Other  dual  mode  configurations  may  have  been  programmed  into  the  lock,  please 
consult the safe or vault supplier. 

 

Duress: 

If the lock has been connected to an alarm system, users can enter a Duress 

code  which  sends  a  silent  signal  to  alert  others  that  the  lock  is  being  opened  under 
duress. To enter a Duress code, use the normal code with the last digit increased by 
1.  E.g.  02-123456  would  become  02-123457.  If  the  last  digit  is  a  9,  it  should  be 
changed to a 0.

 

 

Dynamic codes: 

Dynamic Codes, also known as one-time codes or single use codes 

require  additional  equipment  and  PC  software.  Please  refer  to  separate  Dynamic 
Codes instructions.

 

 

Immediate  timelock  for  Users: 

Users  02-90  have  the  ability  to  access  the  TIME 

MENU and apply immediate timelock, in addition to the Manager. Press   to access 
the main menu then scroll to TIME MENU. Enter a valid User ID and code or press   
to enter the Manager code, then access IMMEDIATE TIMELOCK.

 

 

Manager  management  disabled: 

The  Master  may  have  been  prevented  from 

managing  the  manager  code,  in  which  case  MANAGER  MANAGEMENT  will  be 
unavailable in the Master menu.

 

 

Multi-lock: 

TechMaster can manage up to 5 locks, each with its own lock ID: 1, 2, 3, 

4, 5. Each lock operates independently with its own Master, Manager and User codes, 
and  must  each  be  accessed  independently  for  opening  and  management  using  the 
keypad. Before any action is undertaken, select the relevant lock.

 

 

Opening extension: 

A timelock open period can be extended by up to 2 hours. This 

can be entered in shorter increments if needed. 

 

Press 

  to  access  the  main  menu  then  scroll  to  TIME  MENU.  Press   

  to  accept, 

enter  the  Manager  code.  Press 

  to  accept  OPENING  EXTENSION  then  enter  the 

date and time that the opening period should be extended to.  
If  Users  02-90  have  been  given  access  to  the  TIME  MENU,  a  User  ID  and  code  is 
requested initially, press   to enter the Manager code. 

 

Time Delay Management: 

The Master may manage time delay parameters instead of 

or  in  addition  to  the  Manager.  Access  the  Master  menu  and  scroll  to  TIME  DELAY 
AND OPEN WINDOW

 

 

Time  Delay  Override  Users: 

Some  of  the  Users  02-90  may  have  been  given  the 

ability to override time delay and open the lock immediately. 

 