TTR v.2.04 EN
Introduction
TTR Alarms
General:
• Telephone in machineroom must be connected to the RJ12
jack on the front of the TTR unit.
• RJ12 jack next to the 14 pin connector is for the microphone,
alternatively microphone and external speaker (sold separately).
• The emergency button’s function (NO or NC) is set by the
jumpers on the TTR board (not autodetect).
• Install jumpers on the TTR board, so they stand as the unit
which is replaced (same jumper names).
• Remember to attach the unit, and tighten the screws in the
lid to avoid the device to “rattle”.
• The battery is disconnected at delivery and must be
connected when the TTR is installed.
If using emergency lights:
• To provide 1 hour of emergency lights, the TTR should not
be loaded with more than 3-5W (replace 10W halogen pin
bulb with a 5W bulb)
If using pictograms:
• Pictograms are 12 V, ground (0V) is connected to
terminal input 7 (not terminal input 5)
• Remember to activate TTR’s relays as pictograms (* 88 * 1 #)
If using extra station under the car or in the shaft:
• There should be installed an extra board (SL3000-XRemBoard).
Please read the following info-
rmation, as it contains important
information about differences
between TTR and other
emergency-alarm telephones.