SL1 manual

SL1 v.2.1.0 EN

Lift Emergency Telephone

Reliability – brought to you from 

Tyresö

 Sweden

Содержание SL1

Страница 1: ...www safeline group com 02 2023 2023SafeLineandalltheSafeLineproductsand accessoriesarecopyrightedbylaw SL1manual SL1 v 2 1 0 EN Lift Emergency Telephone Reliability brought to you from Tyres Sweden...

Страница 2: ...pply voltage 10 30 VDC Current consumption max 50 mA Emergency signal button Can be set as N O or N C 10 30 VDC Auxillary input Can be set as N O or N C 10 30 VDC Size H x W x D 100 x 60 x 24mm Operat...

Страница 3: ...Wiring diagram SafeLine SL1 on a PSTN LINE 9 Configuration 10 Configuration overviews 10 Configuration method 12 Configuration unit numbers 13 Configuration examples 14 Parameter list 15 Operating 19...

Страница 4: ...accepts no liability arising from printing errors mistakes or changes Declaration of conformity Download The declaration of conformity at our website www safeline group com Safety Precautions Only tr...

Страница 5: ...inputs 3 RS232 PC connection For firmware update and configuration with SafeLine Pro 4 Keyboard For configuration 5 Volume control Buttons 2 and 8 raises respectively lowers the speaker volume 6 Conn...

Страница 6: ...6 89 5 108 100 69 5 80 29 60 4 5 13 2 98 10 26 3 6 SL1 v 2 1 0 EN Measurements SafeLine SL1 COP Article number SL1...

Страница 7: ...RM 27 57 119 5 PSTN SL1 v 2 1 0 EN Button SafeLine SL1 alarm button with microphone Article number LT stat01 SafeLine SL1 alarm button microphone and speaker Article number LT stat02 Button Speaker Me...

Страница 8: ...gram Filter Alarm button Voltage supply 10 30V Voltage supply 0V Telephone line in Telephone line out to next SafeLine Voltage supply 10 30V Max voltage 12V if using SL Pic Extra remote Extra emer gen...

Страница 9: ...2 1 0 EN Wiring diagram SafeLine SL1 on a PSTN LINE Parallel wiring Two wires required Unit numbers must be pre configured Max 9 units Phone line in Phone line in Daisy chain wiring serial wiring Fou...

Страница 10: ...The unit can be configured at the office prior to the installation or at site after installation The configuration software SafeLine Pro can be downloaded from www safeline group com The configuratio...

Страница 11: ...start the configuration password has to be entered Remote configuration with SafeLine Pro ProLink The unit can also be remotely configured at the office after installa tion Connect a SafeLine ProLink...

Страница 12: ...ngs 3 tones Requested unit answers Enter the password 0000 Press unit no 1 9 repeatedly until recieving 3 tones 1 beep first SL1 answers Multiple units connected to phone line Dial phone number 2 shor...

Страница 13: ...programming 00 Enter the password 0000 Unit number 82 n Terminate programming 00 Programming the unit number Dial phone number First unit answers Program unit as number 1 Hang up Re dial the phone nu...

Страница 14: ...9 4 Call type 1st number 2 1 0 Example Answered with P100 code 5 Call type 2st number 2 2 1 Example Answered as voice call 6 Alarm button delay 8 7 0 3 Example 3 seconds delay 7 End configuration 0 0...

Страница 15: ...switch board delay time can be set by adding asterisks between leading number and telephone number Each asterisk is equal to one second delay Example 11 0 1234567 2nd Phone number 12 3rd Phone number...

Страница 16: ...a Comments Record distress message played in the lift car 51 Speak This message will be played in the lift cabin when the emergency lift telephone starts calling the alarm centre Make sure that there...

Страница 17: ...ed when there is a voice response The call is terminated by pressing 1 Kone ECII lift telephone When there is a voice response some ascending tones will be heard The call is validated by pressing 4 Th...

Страница 18: ...ncy call number 0 OFF 1 ON Default Alarm button delay time 87 Delay time from pressing the alarm button until activating the alarm 00 25 seconds Default 05 Alarm button type 89 0 Normally open contact...

Страница 19: ...seconds Unit is OK Flashing once every 5 seconds Telephone line OK Flashing quickly Flashing twice every second Alarm button active Flashing two times every 5 seconds Alarm filter activated Flashing t...

Страница 20: ...nnected and set to standard Phone line dial tone Connect telephone line Green LED flashes 5 times Short tone in the speaker SafeLine SL1 will make a self test Connect 10 30 VDC Testing the SafeLine SL...

Страница 21: ...With 4 stored telephone numbers in the system each number can be called 3 times This adds up to the 12 call limit Emergency call Emergency alarm activated Dial tone Calling 1st phone number Answer Ca...

Страница 22: ...he volume and check again Interfering noise when the call is connected The problem might be due to induction in the phone cable Accor ding to the phone companies regulations the phone line must be ins...

Страница 23: ...d to above complies with the following EC Directives Directives Electro Magnetic Compatibility 2014 30 EU RoHS 2 2011 65 EU Standards applied EN 81 20 2014 Lift Safety Technical requirements EN 81 28...

Страница 24: ...e no SafeLine Denmark Vallensb kvej 20A 2 th 2605 Br ndby Denmark Tel 45 44 91 32 72 info dk safeline se SafeLine Headquarters Antennv gen 10 135 48 Tyres Sweden Tel 46 0 8 447 79 32 info safeline se...