46
EU Declaration of Conformity SL6+ V2.23
Your partner in lift safety
Antennvägen 10, 13548 Tyresö, Sweden
+46 (0)8-447 79 32, www.safeline-group.com
EU Declaration of Conformity
Product:
Lift telephone
Type / model:
SL6+
Article no:
*SL6, *SL6-4G, *SL6-GSM, *SL6-GSM-BOARD, *SL6-MAINBOARD, *SL6-MINI, *SL6-MINI-4G, *SL6-MINI-GSM, *SL6 A+,
*SL6 A+ MINI, *SL6 A+ 3G, *IF-BOARD-4G, *SL6-GSMR, *SL6-MINI-GSMR
Including voice stations
:
*SLB3-COP, *SLB3-REC-PIC, *SLB3-REC-PIC-B, *SLB3-SM-PIC, *SLB3-SM-PIC-B, *SLB3-SM-PIC-L, *SLB3-SMD-PIC,
*SLB3-SMD-PIC-B, *SLB3-REC-BL, *SLB-COP, *SLB-COP2, *SLB-COP2-L, *SLB-COP-L, *SLB-COP-SEP, *SLB-IF1, *SLB-IF2,
*SLB-RD,*SLB-RD-BUT, *SLB-RD-BL, *SLB-RD-BEL, *SLB-REC, *SLB-REC-FIRE, *SLB-REC-FIRE02, *SLB-REC-FIREK,
*SLB-REC-FIREK02, *SLB-REC-LED, *SLB-REC-PIC, *SLB-REC-PIC-BUT *SLB-SM, *SLB-SM-LED, *SLB-SM-PIC,
*SLB-SM-PIC-BUT, *SLB-SM-PIC-LIGH, *SLB-SMD-PIC-BUT, *SLBR-COP, *SLBR-SM-PIC, *SLBR-SM-PIC-B, *SLBR-REC-PIC,
*SLBR-REC-PIC-B, *SLBR-REC-PIC-B2, *SLBR-REC-PIC3, *SLBR-RD-B-L
Manufacturer:
SafeLine Sweden AB
Year:
2020
We herewith declare under our sole responsibility as manufacturer that the products referred to above complies with the
following EC Directives:
Directives
Radio Equipment (RED):
2014/53/EU
(Including EMC 2014/30/EU, LVD 2014/35/EU)
RoHS 2:
2011/65/EU
Lift
2014/33/EU
(Annex 4.5 & 4.9)
Standards applied
EN 81-20:2014
Lift: Safety & Technical requirements
EN 81-28:2003
Lift: Remote alarm on passenger and goods passenger lifts
EN 81-70:2003/A1:2004
Lift: Accessibility to lifts for persons including persons with disability
EN 81-72:2003
Lift: Firefighters lifts
EN 12015:2014
EMC: Emission, Electromagnetic compatibility
EN 12016:2013
EMC/Lifts: Immunity, Electromagnetic compatibility
EN 62368–1:2014/AC:2015
LVD: Information Technology Equipment
EN 50581:2012
RoHS: Technical doc. for assessment of restriction of RoHS.
For RED 2014/53/EU, an ” EU-Type Examination procedure” has been applied and is certified by notified body:
TÜV AUSTRIA SERVICES GMBH, Notified Body Nr: 0408, Cetrificate Nr:
INE-AT/EMV-18/138
with the supporting assessments:
Standards applied
Article of Directive 2014/53/EU
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013
3.1 (a): Health and safety of the user
EN 62311:2008
EN 301 489-1 v2.1.1 + EN 301 489-52v1.1.0 Draft
3.1 (B): Electromagnetic Compatibility
EN 301 489-17 V3.1.1
EN 301 511 v12.5.1
3.2:
Effective
use
of
spectrum
allocated
EN 301 908-1v11.1.1 /-2v11.1.1 /-13v11.1.1
EN 300 328 V2.1.1
Firmware used during assessment
Triorail TRM-5:
Rev. 03.016 / Rev. 03.017 / Rev. 03.019 / Rev. 03.025
GL865-Dual V3:
16.00.152 / 16.01.150 / 16.01.153
LE910-EU V2:
20.00.402
SafeLine SL6
4.50
Tyresö, 2020-09-08
Lars Gustafsson,
Technical Manager, R&D , SafeLine Group
Module
Notified body
Address
NB nr Test nr
CONNECTable
FORCE Technology
Venlighedsvej 4, 2970 Hørsholm
0199
119-24187-1, 119-24187-2
TRM-5
TÜV AUSTRIA SERVICES GMBH
Deutschstraße 10, 1230 Wien
0408
INE-AT/EMV-18/138
N.A.
TÜV AUSTRIA SERVICES GMBH
Deutschstraße 10, 1230 Wien
0408
INE-AT/IT-18/109
TRM-5
Phoenix testlab GmbH
Königswinkel 10, D-32825 Blomberg, Germany
0700
13-113995
GL865-Dual V3
LE910-EU V2
Dekra Test &Cert
Dekra Test &Cert
Parque Tecnologico de Andalucia / SeveroOchoa 2,
29590 Spain
1909
1909
53051 RBN.001
52382 RCB.001
SafeLine SL6+ v.3.9.0 EN
Mains failure
When mains power has failed, an alarm will be sent after 15
minutes. When mains power returns, an alarm will also be sent.
Mic/speaker failure
Mic/speaker is tested once per day. If one/both fails, alarm will be
sent.
Voice station failure
If the communication is disrupted an alarm will be sent.
If commmunication returns, an alarm will also be sent.
Battery failure
Battery tests are performed every week. If a battery test fails, an
alarm will be sent.
Stuck button
If pushed alarm button does not return to normal position, a stuck
button alarm will be sent.
Internal
operational
failures
If repeat alarms function
is active – an active alarm
will be re-sent each day as
a reminder until problem
is resolved. Applies only to
battery failure, mic/speaker
failure and stuck button
alarms