background image

 
 

 
Page 2 

www.safe-t-cover.com 

1-800-245-6333 

12/28/2020 

1.

 

Do  not  remove  the  PVC  masking  film  until  the  enclosure  is  fully  assembled.  The  PVC 
masking film will protect the finish of the metal panels during installation. 

2.

 

The  concrete  base  should  be  6”  thick,  14”  longer  than  enclosure  ID  and  14”  wider  than 
enclosure ID. Please note that the concrete base should be level, or the access panels may be 
difficult to install. 

3.

 

Mark  the  concrete  base  for  the  outside  of  the  enclosure  using  the  dimensions  in  the  table 
above. See important notice in step 4 before marking. 

4.

 

Important  Notice  -  if  the  enclosure  will  be  installed  over  an  N  pattern  backflow  assembly 
with OS&Y gate valves: Place one “A” PANEL side of the enclosure 1" from the fully open 
OS&Y gate valve STEM. This will allow room for the check valves to be serviced in the “C” 
PANEL OPENING. Once one side of the enclosure is placed 1" from the fully open OS&Y 
gate valve STEM, continue to assemble the enclosure by following the directions below. 

5.

 

Place the other A panel on the concrete pad opposite the “A” panel in step 4. Measure and 
verify the Outside Dimension of these A panels matches what is noted in the table above. 

6.

 

Set “D” (roof) panel on “A” (end) panels. 

7.

 

Temporarily place one “C” (access) panel opposite hinged side of “D” (roof) panel

.

 Square 

the enclosure. 

8.

 

IMPORTANT! 

From inside the enclosure, inspect the alignment of the “D” (roof) panel where it 

meets  the 

“A”  panels  to  ensure  that  “A”  panels  are  placed  securely  within  the  “D”  (roof) 

channel. Fasten “D” (roof) safety hooks before connection of the “D” (roof) to the “A” panels. 

9.

 

Fasten “D” (roof) panel to “A” (end) panel by attaching the roof hinges to “A” (end) panels 
with three (3) screws provided. (Fig 1A) 

10.

 

Remove “C” (access) door panel. 

11.

 

IMPORTANT! THE “D” ROOF PANEL MUST BE CONNECTED TO THE “A” PANELS 
BEFORE ANCHORING ENCLOSURE TO THE SLAB. 

12.

 

IMPORTANT! Fasten each Inside Corner Aluminum Anchoring Brackets to the “A” panel 
with  hex  head  screws  as  shown  in  Fig.  1B,  then  fasten  to  concrete  base  with  anchors 
provided. 

13.

 

Release  safety  hooks  and  raise  roof.  Snap  lift  shocks  onto  brackets  by  snapping  the  shock 
socket  over  the  ball  of  each  bracket

(Fig  1C)  Be  sure  the  cylinder  end  of  the  shock  is 

attached to the roof. 

Отзывы: