INSTALLATION INSTRUCTIONS 

!

 WARNING

 

FAILURE  TO  FOLLOW  THESE  INSTRUCTIONS  MAY 
RESULT  IN  A  MALFUNCTION  OR  FAILURE  OF  THE 
ALARM AND MAY VOID THE WARRANTY. 

Power Supply: Sealed In 3V Long life Lithium battery 
 

Follow  these  instructions  carefully.  Failure  to  follow  these 
instructions can damage the unit and void the warranty. Select a wall 
location at least 4” off the floor. 

 

SA-339: 

Having established the mounting location ensure that there 

is no electrical wiring or pipe work in the area adjacent to the 
mounting surface.  

 
Place detector against the wall (at least 4” from the floor) or ceiling. 
Mark the 3 hole locations.  Remove the detector. 

 

Drill holes at the 3 marked locations with a drill bit. Insert the 
molly’s into the holes. Align the detector over the holes and tighten 
screws in each hole. 

 

BE SURE PULL TAB IS VISIBLE after installation and not 
twisted. Pull on tab to remove, starts the detectors/operation. 

 

Note you may remove the pull tab prior to installation, but alarm 
may sound if test button is accidentally pushed.   

 

 

TEST PROCEDURE

 

!

 WARNING 

TO  REDUCE  THE  RISK  OF  CARBON  MONOXIDE  POISONING, 
TEST  THIS  ALARM’S  OPERATION  AFTER  THE  RV  HAS  BEEN 
IN  STORAGE,  BEFORE  EACH  TRIP  AND  AT  LEAST  ONCE  PER 
WEEK DURING USE

!

 

WARNING 

WARNING:  THE  TEST  BUTTON  ONLY  TESTS  THE 
ALARM  CIRCUIT  NOT  THE  SENSORS.  TO  TEST  THE  CO 
SENSOR USE A CAN OF SAFE-T-ALERT CO TEST GAS TO 
TEST THE 400 PPM CALABRATION POINT. DO NOT TRY 
TO GENERATE CO TO TEST THE ALARM.

  The TEST/RESET 

button  tests  all  ELECTRICAL  functions  of  the  alarm.  It  does  not 
check the sensor operation. 

The  alarm  may  be  tested  at  any  time  -The  TEST/Mute  switch  is 
located on the front of the alarm Press and hold the test button for 1 
second.  The alarm is working properly if the GREEN indicator light 
changes color to RED and the horn beeps 4 times.  

IMPORTANT

 - 

 If this alarm does not test properly return it immediately 

for repair or replacement. 

 

 
 
 

OPERATION

 

 

To  operate  this  CO  alarm,  pull  on  tab  to  remove;  this  starts  the 

detectors/operation. If the ON indicator light does not light, see the section,

 

Trouble-Shooting  Guide

,  in  this  manual  for  further  information.   

Do  not 

attempt to fix it yourself. 

 

VISUAL AND AUDIBLE ALARM SIGNALS 

This  SAFE-T-ALERT

TM

 

CO  Alarm  is  designed  to  be  easy-to-operate.  The 

alarm  has  two  indicator  lights  that  display  a  specific  color  for  each 
monitored  condition.  There  also  is  a  matching  sound  pattern  for  alarm 
conditions. 

 

CO ALARM 

The  Red  CO  LED  will  flash  and  the  alarm  will  sound  4  “BEEPS”  then 
silent  for  5  Seconds

.   

These  signals

 

indicate  that  the  CO  level  is  over  35 

ppm.

 IMMEDIATE ACTION IS REQUIRED. 

See 

Procedures To Take 

During An Alarm

. This cycle will continue until the TEST/Mute button on 

the front of alarm is pressed. Ventilate the RV. The RED light will stay ON 
until  the  CO  has  cleared,  or  the  alarm  will  reactivate  in  approximately  6 
minutes  if  the  CO  is  still  present.  DO  NOT  RE-ENTER  THE  RV.  This 
alarm will return to normal operation after the RV s properly ventilated. 

 

 

MALFUNCTION/SERVICE SIGNAL 

If any malfunction is detected, the 

Operational/CO  LED  will  alternate  Red/Green  and  the  alarm  will  sound 
once every 15 seconds. Press the Test/Mute button. If the Test/Mute button 
does not clear the signals, check the battery voltage. I

f the battery voltage 

is not low and the unit will not return to normal operation,

 

immediately 

remove the alarm and return for service or warranty replacement.

 See 

the warranty section in this manual. 

 

   

OPERATION 

  

 

  NORMAL 

 

 

   
  CO ALARM 
    

 

  

   

  

  ALARM  
  MALFUNCTION 
 
  END OF LIFE 
 
 
  WARM UP CYCLE 

  (ABOUT 10 MINUTES)

 

     

AUDIBLE SIGNAL        VISUAL SIGNAL

  

 

                                       

        NONE                      GREEN LED FLASHES 

                                           EVERY MINUTE 

   

   

  

 

      

4 “BEEPS”                    STEADY RED 

      5 SECONDS OFF 

 

 

“    

   

  

“    BEEP EVERY              ALTERNATING 

   30 SECONDS               RED/GREEN 

 
B   BEEPS EVERY            RED RED GREEN GREEN   
     25-30 SECONDS          FLASHING  
  
     NO SOUND                   FLASHING GREEN  

 

TROUBLE-SHOOTING GUIDE  

Use this chart to trouble-shoot problems with this SA-339 Alarm. 

PROBLEM 

   

CAUSE/SOLUTION 

Green Operational LED Off 

1.Dead or Missing Battery 

 

2. Contact Customer Service                                      

No Sound When Testing  

Contact Customer Service 

No Red LED When Testing  

Contact Customer Service 

Locked In Alarm 

 

Contact Customer Service

 

 

MALFUNCTION ALARM LED  1. Check Battery Voltage 
Red/Green & Beeps 
Every 15 Seconds   

 

Battery Voltage is Good and it 

2. Contact Customer Service 

Will Not Reset To Normal operation  

END OF LIFE ALARM   

Push reset button to reset for               
3 days – Replace within 30 days.

        

                                           

Customer Service 800-383-0269    www.safetalert.com 