background image

Fold Here

Installation

1. 

Install the mounting assembly (arm and base) in a preferred location. To do so: 

i. 

Loosen the tamper-resistant nut on the 

mounting arm using the tri-groove nut 

driver (available for purchase separately), 

and then detach the base plates.

ii. 

Attach one of the base plates to the 

mounting surface of the vehicle using the 

supplied self-tapping Torx screws and the 

security Torx L-key.

iii. 

Reattach the arm to the base plate, and 

then lightly tighten the tri-groove tamper-

resistant nut.  

 

 

2. 

Attach the other base plate to the back of 

the dock, using the supplied Torx screws and 

spring lock washers.  

 

 

 

                                                                                                    

3. 

Attach the dock-mounted base plate to the mounting arm, adjust the position of the dock, and 

then tighten the tri-groove tamper-resistant nut.

4. 

Run the power cable to the source and connect as follows:

•  Black wire to ground
•  Red wire to vehicle’s battery via the supplied fuse holder, using the supplied butt splice
•  Yellow wire to vehicle’s IGN or ACC via the supplied fuse holder, using the supplied butt splice.

5.  Connect the GPI harness as follows:

• 

Black wire to ground (must be connected)

• 

Blue wire to Stop Arm signal, which connects to the flashing red light indicator.

NOTE:

 Green, brown, and yellow wires are reserved for future use.

6.  Connect the RFID card reader to the dock’s pigtail as follows: 

If...

Then...

Using 

a serial 

reader

1.  Connect the RFID harness’s USB connector to the pigtail’s USB port.
2. 

Connect the RFID harness’s 2x4 micro-fit connector to the pigtail’s COM 1/2 port.

3.  Connect the reader:

• 

If using a 

micro-fit RFID reader

, connect the RFID harness’s 2x2 micro-fit 

connector #1 to the serial reader’s micro-fit connector either directly or via 

a supplied serial extension cable.

• 

If using a 

DB9 RFID reader 

(pictured on the diagram), connect the RFID 

harness’s 2x2 micro-fit connector #1 to the adapter cable’s 2x2 micro-fit 

connector either directly or via a supplied serial extension cable, then 

connect the adapter cable’s DB9 connector to the serial reader’s DB9 

connector.

NOTE:

 The RFID harness’s 2x2 micro-fit connector #2 is reserved for future use.

Towards the dock

Installation diagram

 

COM 1/2

GPI

Red

3 A fuse

3 A fuse

Yellow

Red: to battery

For future use

Universal USB reader

Serial reader with 

a DB9 connector

Yellow: to IGN or ACC

USB

Ground

Green, brown, yellow: 

for future use

Blue: to Stop Arm signal 

(connects to the flashing red 

light indicator)

Ground

(must be 

connected)

- OR-

- OR-

#1

#2

 NOTE: Choosing a location

Choose a location where the driver will 

be able to clearly see the MDT screen. 

The MDT should have a clear view of 

the sky to ensure the best GPS and 

cellular reception.

 NOTE: Typical installation 

The following instructions describe a 

typical installation that includes the 

use of the optional mounting arm. 

Base plate

Tri-groove nut

Tri-groove 

nut driver

1

2

3

4