Both the current BW and CENTRE values are displayed in white (when selected). If 

the  entered  BW  value  is  equal  or  smaller  than  the  current  frequency  SPAN,  and 
CENTRE  frequency  is  inside  of  the  current  frequency  SPAN,  it  will  be  displayed  in

 

bright  green

.  Invalid  entered  values  are  displayed  in

 

red

.  If  a  CENTRE  frequency  is 

outside of the current frequency SPAN, a 

pink 

arrow above the grid will indicate its 

position  in  relation  to  the  current  frequency  SPAN.  Also  both  the  POWER  IN  BAND 
status indication and the POWER IN BAND button in the HOME screen will be shown 
in 

purple 

in this situation. See screenshot below. 

 

POWER IN BAND out of SPAN 

Содержание Spectrum Compact

Страница 1: ...1 User manual Spectrum Compact VER 1 7 FW V3 31...

Страница 2: ...t different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Changes or modifications not expressly approved by the party responsible for...

Страница 3: ...NCY menu 9 2 5 SPAN menu 12 2 6 MARKER menu 13 2 7 HIGH CONTRAST button 15 2 8 TRACE MODE menu 16 NORMAL 16 MAXHOLD 16 CUMULATIVE 17 AVERAGE 2 4 8 16 18 FILL 19 2 9 TOOLS menu 20 2 9 1 SETTINGS submen...

Страница 4: ...g purposes Built in LCD touchscreen ensures smooth and intuitive on site use of the spectrum analyser which can be connected directly to any antenna via SMA connector The industry leading sensitivity...

Страница 5: ...D indication when charging Battery 2380 mAh Polymer Lithium ion Battery life up to 4 h Operating temperature 15 C to 55 C 5 F to 131 F Dimensions 128x81x24 mm 5 04x3 2x0 94 in Weight 0 3 kg 10 6 oz P...

Страница 6: ...UBR84 to SMA 5 9 10 0 GHz WR112 P N J0S10WA003 UBR100 to SMA 8 2 12 GHz WR90 P N J0S15WA003 UBR140 to SMA 12 17 GHz WR62 P N J0S22WA003 UBR220 to SMA 17 24 3 GHz WR42 P N J0S26WA001 UBR260 to 2 92 22...

Страница 7: ...ensure continuous operation 1 5 Connecting to antenna 1 Connect an appropriate 50 coaxial cable to SMA or 2 92mm connector antenna port 2 Attach waveguide to coaxial converter to an antenna or radio...

Страница 8: ...ions and the vertical 4 divisions The horizontal axis represents a linear frequency scale that increases from left to right The vertical axis represents a logarithmic power scale that increases from b...

Страница 9: ...ve battery power or if you plan to save or analyse a specific measurement 2 3 SAVE button Pressing the SAVE button instantly saves the visible spectrum in a separate spectrum curve file The list of sa...

Страница 10: ...Hz frequency SPAN is changed in accordance with the modified frequencies The selected frequency is displayed in white Unselected frequencies are displayed in blue An incorrectly entered value is displ...

Страница 11: ...ACT 11 In FREQUENCY or HOME screens you can tap left or right on the spectrum graph to move the frequency left or right Entering invalid START frequency Entering correct START frequency Entering START...

Страница 12: ...ULL SPAN would change the CENTRE frequency it will be displayed in purple otherwise in grey Maximum frequency SPAN FULL SPAN depends on Spectrum Compact model 6000 6075 8000 7300 or 16000 MHz Minimum...

Страница 13: ...visible spectrum it will be displayed in bright green otherwise in pink Invalid entered values are displayed in red If an entered MARKER frequency is outside the current frequency SPAN a pink arrow lo...

Страница 14: ...on in the top left corner of the screen to display bigger digits While in the MARKER screen tap left or right on the spectrum grid to move the Marker left or right To move the MARKER faster tap and ho...

Страница 15: ...y default High contrast mode changes the colour of the spectrum graph and the controls to black and white for maximum visibility in direct sunlight Tap the HIGH CONTR button in the HOME screen to acti...

Страница 16: ...equency points with higher power levels are updated Tapping the MAXHOLD button repeatedly resets the MAXHOLD trace A counter below the grid shows in blue the number of sweeps since the beginning of th...

Страница 17: ...e power levels of each frequency for all previous sweeps since sweeping commenced During each sweep only the frequency points with previously unsaved levels are updated CUMULATIVE trace mode allows se...

Страница 18: ...AGE 2 4 8 16 sets a sweep averaging mode whereby the trace shows the average values of the two four eight or sixteen most recent sweeps Tapping the AVERAGE 2 4 8 16 button repeatedly restarts averagin...

Страница 19: ...w the spectrum curve This mode can be enabled only for the following trace modes NORMAL MAXHOLD AVERAGE 2 AVERAGE 4 AVERAGE 8 and AVERAGE 16 Repeatedly tapping FILL will revert to the default spectrum...

Страница 20: ...visible on the screen which are on different harmonic frequencies F 2 F 2 F 3 2 etc Such signals can appear if input signal strength exceeds 60dBm and they will be filtered up to 80 90 dBm on the scr...

Страница 21: ...activated gray DEMO Demo mode is a signal pattern imitation and allows you to fully test Spectrum Compact functionality without the presence of an actual input signal When active DEMO ON will appear b...

Страница 22: ...nd day and time hours and minutes by tapping on the appropriate parameter Note that the time is set in a 24H format When Spectrum Compact is connected to a PC and the Spectrum Manager software is runn...

Страница 23: ...be previewed on the current spectrum in bright green Tap the SET AS MASK button to activate the selected reference mask curve The activated spectrum curve file as well as the reference mask curve wil...

Страница 24: ...d on the frequency span bar When active the MASK MODE submenu will be displayed in red in the TOOLS menu Repeatedly tapping the MASK MODE submenu button will deactivate the mask curve MASK MODE is use...

Страница 25: ...ofile can be previewed by tapping the VIEW button and restored by tapping the SET button 2 9 4 LEVEL submenu LEVEL allows defining input power level range Y axis in decibels referred to miliwatts dBm...

Страница 26: ...SPECTRUM COMPACT FW 3 31 USING SPECTRUM COMPACT 26 Entering LEVEL menu Setting 20 dB OFFSET Setting MAX and MIN dBm...

Страница 27: ...es using the up and down arrow buttons After entering VIEW mode the current spectrum is lost and therefore the SAVE button disappears Filenames are formed according to the trace mode used Cxxxxx corre...

Страница 28: ...the STOP button stops the recording and saves it The maximum length of a recording is 30 minutes If the recording is not manually stopped earlier then after this time the next recording is started aut...

Страница 29: ...3 31 USING SPECTRUM COMPACT 29 2 9 8 ABOUT submenu This submenu displays information about the Spectrum Compact frequency range serial number firmware and hardware versions A new recording Paused reco...

Страница 30: ...requency by tapping CENTRE MHz and entering the required frequency manually via numpad and tapping the ENTER or CENTRE MHz buttons by tapping anywhere on the spectrum grid When POWER IN BAND is active...

Страница 31: ...rent frequency SPAN it will be displayed in bright green Invalid entered values are displayed in red If a CENTRE frequency is outside of the current frequency SPAN a pink arrow above the grid will ind...

Страница 32: ...software 2 Plug your Spectrum Compact unit into the PC via USB and wait for the software to connect to your Spectrum Compact 3 Click on the Start Real Time button 4 On the right of the screen you ll...

Страница 33: ...ka com TECHNICAL SUPPORT E MAIL techsupport saftehnika com PHONE 371 670 468 40 FAX 371 670 468 09 Office hours Monday Friday 9 00 AM 6 00 PM UTC GMT 3 hours North America office SAF North America LLC...

Отзывы: