INTEGRA-W/INTEGRA-WS User Manual INTERFACES
SAF Tehnika JSC
75
Chapter 6:
INTERFACES
RJ-45 ports (MNG & LAN)
RJ-45 ports (MNG & LAN) comply with IEEE 802.3-2005 1000Base-T Ethernet and IEEE
802.3at, LTPoE++ Power over Ethernet standards. MNG port additionally complies with
100Base-T Ethernet standard.
The pinouts are as follows:
In case Ethernet cable is used for power & data (with PoE injector), combined Ethernet cable
length from PoE injector to
Integra-W/Integra-WS
FODU and from PoE injector to CPE is
limited to 100m / 328ft.
In case SFP interface (LAN) is configured for data traffic, it is possible to use RJ-45 port
solely for power supply. Two options are possible:
1)
Ethernet cable with PoE injector.
Please refer to table below for maximum Ethernet cable length from PoE injector to
Integra-W/Integra-WS
FODU based on AWG wire size and
Integra-W/Integra-WS
FODU power consumption.
AWG
Lmax @ 45W
Lmax @ 40W
Lmax @ 35W
26
202m / 662ft
227m / 745ft
259m / 851ft
24
321m / 1053ft
361m / 1184ft
413m / 1353ft
22
510m / 1674ft
574m / 1884ft
656m / 2153ft
2)
2-wire power cable together with DC power adapter cable for
Integra-W/Integra-WS
(P/N D0ACPW01).
Please refer to the tables below for maximum power cable length based of AWG wire
size or cross-section and
Integra-W/Integra-WS
FODU power consumption.
AWG
Lmax @ 45W
Lmax @ 40W
Lmax @ 35W
24
80m / 263ft
90m / 296ft
103m / 338ft
22
127m / 419ft
143m / 471ft
164m / 538ft
20
203m / 666ft
228m / 749ft
260m / 856ft
18
322m / 1058ft
362m / 1190ft
414m / 1360ft
16
512m / 1682ft
576m / 1892ft
659m / 2163ft
14
815m / 2675ft
917m / 3010ft
1048m / 3440ft
Cross-section area
Lmax @ 45W
Lmax @ 40W
Lmax @ 35W
0.25mm
2
101m / 331ft
113m / 370ft
129m / 423ft
0.5mm
2
201m / 659ft
226m / 741ft
259m / 849ft
0.75mm
2
302m / 990ft
339m / 1112ft
388m / 1273ft
1.0mm
2
402m / 1318ft
452m / 1482ft
517m / 1696ft
1.5mm
2
603m / 1978ft
679m / 2227ft
776m / 2545ft
Pin
Data
PoE
1
Bi-directional A+
VB1+
2
Bi-directional A-
VB1+
3
Bi-directional B+
VB1-
4
Bi-directional C+
VB2+
5
Bi-directional C-
VB2+
6
Bi-directional B-
VB1-
7
Bi-directional D+
VB2-
8
Bi-directional D-
VB2-
Содержание Integra-W Series
Страница 1: ...User manual Integra W WS Full Outdoor Unit VER 1 01 FW 2 6 6 ...
Страница 14: ...INTEGRA W INTEGRA WS User Manual INSTALLATION SAF Tehnika JSC 14 ...
Страница 32: ...INTEGRA W INTEGRA WS User Manual WEB GUI SAF Tehnika JSC 32 Status mode Press button ...
Страница 37: ...INTEGRA W INTEGRA WS User Manual WEB GUI SAF Tehnika JSC 37 Status mode Press button Modify mode ...
Страница 56: ...INTEGRA W INTEGRA WS User Manual WEB GUI SAF Tehnika JSC 56 Status mode Press button Modify mode ...
Страница 82: ...SAF Tehnika JSC 24a Ganibu dambis Riga LV 1005 Latvia EU sales saftehnika com www saftehnika com ...