Many problems with inset fires are caused by badly working chimneys. Therefore some suggestions:
A round channel is preferred (minimum friction)
The diameter of the chimney may not be smaller at any point than that of the appliance (except in very long
chimneys where a narrower section should sometimes be included)
The mouth of the chimney should be unobstructed
The chimney should be as close as possible to vertical with as few curves as possible.
The chimney must not draw in extra air. Watch out for flue dampers and cleaning hatches in the cellar or on the
roof!
The chimney may not have too many connections - that reduces the upwards pressure. Consult your chimney
specialist!
Flue connections to different inset fires and fireplaces may not be located opposite each other at the same height,
in order to prevent the chance that combustion gases will not be drawn out. Two flue connections must be at
separated vertically by at least 30 cm.
For the chimney opening, you will need to comply with your national legislation. For Belgium this is NBN 61-001.
Zone 1 :
A chimney opening
is automatically
permitted (preferably
without a static cowl)
Zone 2 :
A chimney opening is only permitted if the
appliance(s) is /are fitted with an atmospheric
burner and if a static cowl is fitted to the top of the
chimney..
Zone 3 :
A chimney opening is not
permitted under any
circumstances.
For details on chimneys we refer you to the relevant regulations with which the chimney needs to comply.