Before seeking service, users should first inspect the unit and record fault details
according to information in this section. If service is required, please contact Saelig.
Fault
code
Fault type
Possible causes of faults
Solutions
Err-01
U-phase IGBT1 over current fault
U-phase IGBT is damaged
Check and replace IGBT
Err-02
U-phase IGBT2 over current fault
U-phase IGBT is damaged
Check and replace IGBT
Err-03
U-phase IGBT3 over current fault
U-phase IGBT is damaged
Check and replace IGBT
Err-04
U-phase IGBT4 over current fault
U-phase IGBT is damaged
Check and replace IGBT
Err-05
V-phase IGBT1 over current fault
V-phase IGBT is damaged
Check and replace IGBT
Err-06
V-phase IGBT2 over current fault
V-phase IGBT is damaged
Check and replace IGBT
Err-07
V-phase IGBT3 over current fault
V-phase IGBT is damaged
Check and replace IGBT
Err-08
V-phase IGBT4 over current fault
V-phase IGBT is damaged
Check and replace IGBT
Err-09
W-phase IGBT1 over current fault
W-phase IGBT is damaged
Check and replace IGBT
Err-10
W-phase IGBT2 over current fault
W-phase IGBT is damaged
Check and replace IGBT
Err-11
W-phase IGBT3 over current fault
W-phase IGBT is damaged
Check and replace IGBT
Err-12
W-phase IGBT4 over current fault
W-phase IGBT is damaged
Check and replace IGBT
Err-13
Radiator over-temperature
The fan works abnormally
Check the fan
Err-14
Transformer over-temperature
The fan works abnormally
Check the fan
Err-15
Emergency stop button
The emergency stop button
is presses
Check the emergency stop
button
Err-16
Fuse 1 is broken
The fuse blows out
Check and replace the fuse
Err-17
Fuse 2 is broken
The fuse blows out
Check and replace the fuse
Err-18
Fuse 3 is broken
The fuse blows out
Check and replace the fuse
Err-19
IGBT over-temperature 1
The fan works abnormally
Check the fan
Err-20
IGBT over-temperature 2
The fan works abnormally
Check the fan
Err-21
Input under voltage fault
The input voltage is too low
Check the input voltage
Err-22
Input over voltage fault
The output voltage is too high
Check the input voltage
Err-23
DC voltage is too low
The input voltage is too low
Check the input voltage
Err-24
DC voltage is too high
The output voltage is too high
Check the input voltage
Err-25
U overload
U-phase overload
Check the load
Err-26
V overload
V-phase overload
Check the load
Err-27
W overload
W-phase overload
Check the load
Err-28
Output under voltage fault
The output voltage is too low
Check the output voltage
Err-29
Output over voltage fault
The output voltage is too high
Check the output voltage
Table 7-1 Alarm contents and solutions