REV. 00 - Mar. 07
Total pre-ground coffee beverages
v
Total
beverages
not
modifiable
v
Water
used
(ml.) not
modifiable
Total all beverages
v
Total
beverages
not
modifiable
5.2.2 Total counters
Water used since production (ml.)
not modifiable
Water used since last descaling (ml.)
modifiable
Water used since last descaling message (ml.)
not modifiable
Water used since last descaling (ml.)
not modifiable
v
Water used counter (last) 0 ml.
v
Water used counter (second last) 1 ml.
v
Water used (third to last) 2 ml.
not modifiable
Total
descaler
used
not
modifiable
Water used by filter since last reset (ml.)
modifiable
Water used with water filter enabled since production (ml)
not modifiable
Number
of
descalings
(cycles)
not
modifiable
Number of dispensing head cleaning cycles
not modifiable
Number of milk circuit rinse cycles
not modifiable
Number of cappuccino valve cleaning cycles
not modifiable
Water filters used since production (cycles)
not modifiable
Number of dispensing head removals (cycles)
not modifiable
Beverages up to descaling (cycles)
modifiable
Machine
active
time
(sec.)
not
modifiable
Temporary
descaling
counter
not
modifiable
Water circuit emptying counter (cycles)
not modifiable
5.2.3 Error counters (access submenu)
The machine records the followingerrors (see also section 5.3)
01) Grinder 1 blocked
02) Grinder 2 blocked
03) Dispensing head blocked; up command
04) Dispensing head blocked; down
05) Pump flow rate error (fill circuit)
07) Multivalve blocked
08) Capp. valve. blocked
09) Powercomm error (communication error with power card)
10) Water boiler sensor disconnected
11) Water boiler sensor short circuited
12) Steam boiler sensor disconnected
13) Steam boiler sensor short circuit
14) Water boiler disconnected
15) Steam boiler disconnected
16) Both dispensing head microswitches active
17) EEPROM read and write error
18) Real time clock oscillator stopped
19) No zero crossing in mains supply
20) Cuplift both microswitches active
All these errors display the following submenu
v
Production
errors not
modifiable
v
Errors
since
last
service
resettable
–
modifiable
v
Current
resettable
–
modifiable
Ringbuffer errors: the last 20 errors are saved.
v
Error 1/20,2/20,3/20,4/20,5/20,6/20,7/20,8/20,9/20,10/20,11/20,12/20,13/20,14/20,15/20,
16/20,17/20,18/20,19/20,20.
5/20
PRIMEA Chapter 05
Содержание PRIMEA LINE 2007
Страница 3: ...REV 00 Mar 07 CHAPTER 1 INTRODUCTION REV 00 PRIMEA 2007 Chapter 01 ...
Страница 5: ...REV 00 Mar 07 CHAPTER 2 TECHNICAL DATA REV 00 PRIMEA 2007 Chapter 02 ...
Страница 9: ...REV 00 Mar 07 CHAPTER 3 BRIEF INSTRUCTIONS REV 00 PRIMEA 2007 Chapter 03 ...
Страница 15: ...REV 00 Mar 07 CHAPTER 4 DIAGRAMS REV 00 PRIMEA 2007 Chapter 04 ...
Страница 16: ...REV 00 Mar 07 4 1 Wiring diagram 1 6 PRIMEA 2007 Chapter 04 Primea Touch Plus ...
Страница 17: ...REV 00 Mar 07 Primea Touch 2 6 PRIMEA Chapter 04 ...
Страница 18: ...REV 00 Mar 07 Primea Ring 3 6 PRIMEA Chapter 04 ...
Страница 22: ...REV 00 Mar 07 CHAPTER 5 TROUBLESHOOTING REV 00 PRIMEA 2007 Chapter 05 ...
Страница 43: ...REV 00 Mar 07 CHAPTER 6 OPERATING LOGIC REV 00 PRIMEA Chapter 05 ...
Страница 53: ...REV 00 Mar 07 CHAPTER 7 COMPONENT ASSEMBLY AND DISASSEMBLY REV 00 PRIMEA 2007 Chapter 07 ...
Страница 76: ...REV 00 Mar 07 CHAPTER 8 SERVICE SCHEDULE REV 00 PRIMEA 2007 Chapter 08 ...
Страница 78: ...REV 00 Mar 07 CHAPTER 9 AMENDMENTS MADE TO TECHNICAL SERVICE MANUAL PRIMEA Chapter 09 REV 00 ...