Display Screen Symbols

 1. 

Battery

 – remaining battery power.

 2. 

Lock

 – prevents unwanted changes to the  

 

 

  intensity level. To lock, simply tap the 

 

 

lock icon in the top right corner. 

 

 

To unlock, tap again.

 3. 

Time

 – length of time remaining.

 4. 

Body Part

 – treatment can be provided to  

      the feet and/or hands.

 5. 

Intensity Arrow

 – press the up or down  

      arrow keys to adjust the intensity.

 6. 

Pause

 – when the stimulator is running  

 

 

a treatment program, press the pause  

 

 

button once to pause the treatment. 

 

 

To continue the treatment, press the 

 

 

pause button again. If the unit has been  

 

 

paused for more than 5 minutes, 

    the device will shut off  automatically.

Figure 2

1

2

3

4

4

5

5

6

Содержание Stim Spa

Страница 1: ...INSTRUCTION MANUAL Saebo SaeboStim Spa ...

Страница 2: ......

Страница 3: ...nts your program by providing multiple evidence based treatment solutions that may enhance overall functional recovery This manual contains important information for both the person who will use the SaeboStim Spa and the clinician who may provide and setup the device Please consult your physician prior to starting treatment with the SaeboStim Spa Also please be sure to review all information caref...

Страница 4: ... 9 Adverse Effects 9 EMC Precautions 9 Disposal of Waste and Electronic Products WEEE 10 Description of Device and Controls 11 Device Features 11 Display Screen Symbols 12 Unpacking the Device 13 Getting Started 14 22 Treatment Frequency 22 Program Parameters 22 23 Charging the Battery 24 Troubleshooting 24 Service Life 25 Service and Maintenance 25 2 ...

Страница 5: ...e It is compliance with WEEE Manufacturer The first number 2 Protected against access to hazardous parts with a finger and the jointed test finger of 12mmø 80mm length shall have adequate clearance from hazardous parts and protected against solid foreign objects of 12 5mmø and greater The second number 2 Protected against vertically falling water drops when enclosure is tilted up to 15 Vertically ...

Страница 6: ...he chest may cause rhythm disturbances to your heart which could be lethal Do not apply stimulation over open wounds or rashes or over swollen red infected or inflamed areas or skin eruptions e g phlebitis thrombophlebitis varicose veins Do not apply stimulation over or in proximity to cancerous lesions Intended Use The SaeboStim Spa delivers muscle and nerve stimulation The indications for use in...

Страница 7: ...esence of electronic monitoring equipment e g cardiac monitors ECG alarms which may not operate properly when the electrical stimulation device is in use Do not use this device if you have a cardiac pacemaker implanted defibrillator or other implanted metallic or electronic device Such use could cause electric shock burns electrical interference or death Do not apply stimulation when in the bath o...

Страница 8: ...o using the device after a recent surgical procedure because stimulation may disrupt the healing process Use caution if stimulation is applied over areas of skin that lack normal sensation Keep this device out of the reach of children Use this device only with the leads electrodes and accessories recommended by the manufacturer and Use this device only under the continued supervision of a licensed...

Страница 9: ...ields such as TV S microwave ovens and hi fi speakers as these may affect the LCD screen Keep the device away from a fireplace or radiant heater as the heat may affect the device Keep the device away from nebulizer or steam kettle as the moisture may affect the device Keep the device away from sunlight as long term exposure to sunlight may affect the rubber become less elastic and cracked Keep the...

Страница 10: ...a sudden change in bowel habits or rectal bleeding A prescription drug regimen Keep out of reach of children In case of an overdose call poison control at 800 222 1222 right away Warnings Do not put the lead wire on or wrapped around the neck Do not inhale or swallow small parts Replacement by inadequately trained personnel could result in a hazard Parts of the ME equipment that are not serviced o...

Страница 11: ...hould stop using the device and should consult with their physicians if they experience adverse reactions from the device or redness on the skin that doesn t go away after treatment EMC Precautions Wireless communications equipment such as wireless home network devices mobile phones cordless telephones and their base stations walkie talkies can affect this equipment and should be kept at least a d...

Страница 12: ...ply thrown away New products are now being marked with the symbol to remind you Your local council or retailer will be able to tell you where your nearest facility is The collection facilities will send items for treatment recovery and recycling so by using them you ll help to save resources and minimize the effects on the environment Leave the remaining piece of film on each Gel Pad until the dev...

Страница 13: ...will light up Press and hold this button for 3 seconds again and the unit will turn off 2 Output Ports 2 Lead Wires insert into the Ports on the bottom portion of the device 3 DC Jack the stimulator can be powered through an AC adaptor Connect one end to the power source and the other to the bottom of the device The DC Jack is located in between the 2 Output Ports 4 Belt Clip Located on the back o...

Страница 14: ...e remaining 4 Body Part treatment can be provided to the feet and or hands 5 Intensity Arrow press the up or down arrow keys to adjust the intensity 6 Pause when the stimulator is running a treatment program press the pause button once to pause the treatment To continue the treatment press the pause button again If the unit has been paused for more than 5 minutes the device will shut off automatic...

Страница 15: ...kaging Verify that all parts listed under the System Components section are present See Figure 3 1 SaeboStim Spa Device 2 Conductive Foot Bath 3 Lead Wires 4 2 Carbon Rubber Electrodes 13 5 Power Adaptor Power Cord 6 Carrying Case not shown 7 Epsom Salt 8 Effervescent Tablets Figure 3 1 2 3 7 8 5 4 ...

Страница 16: ...w are also applicable for the hands For convenience purposes the foot application will be described below Step 1 Powering the Device To charge the SaeboStim Spa connect the Power Cord to the Power Adaptor and insert the cord into the bottom of the device between the 2 Ports See Figures 4 and 5 Figure 4 14 Figure 5 ...

Страница 17: ...ttery go to zero and charge periodically even if not used Li ion batteries if well maintained are good for 4 5 years before degrading Step 2 Connecting Lead Wires to Device Plug the T shaped end of the red Lead Wire into Port 2 and the T shaped end of the black Lead Wire into Port 1 found on the bottom of the device See Figures 6 and 7 Figure 6 Figure 7 ...

Страница 18: ...er Electrodes Connect the pin side of the Lead Wires to the 2 Carbon Rubber Electrodes See Figure 8 Figure 8 Note This system includes custom Lead Wires and Rubber Electrodes If you need to replace your Lead Wires or Electrodes only use the manufacture versions ...

Страница 19: ...h warm water or cool if you prefer and place in front of where you will be sitting for your treatment Be sure to have a towel to dry your feet after use See Figure 9 B Add 1 tablespoon of Epsom Salt to each side of the Foot Bath and stir The Salt is highly conductive allowing for efficient stimulation For dry feet reduce to 1 teaspoon See Figure 10 Figure 10 ...

Страница 20: ...he Foot Bath and stir The Tablets help improve dry feet as it contains collagen vitamin C and other moisturizing agents In addition the Tablet also contains menthol to provide a topical analgesic effect See Figure 11 Figure 11 Caution Refer to Pages 8 9 before use ...

Страница 21: ...is completely underwater Place electrode on same side as the affected foot Next submerge the black Carbon Rubber Electrode Port 1 on the other side The black Electrode will be used for the non affected foot If both sides are affected it is recommended to alternate the Electrodes per session See Figure 12 In a seated and comfortable position place your feet into the Foot Bath See Figure 13 Figure 1...

Страница 22: ...1 the above steps are the same if using for your hands instead of the feet Note 2 The red and black Electrodes should not touch during treatment nor should they touch your feet Step 6 Turn On Turn the device on by pressing the On Off button on the side of the unit for 3 seconds See Figure 14 The LCD display will light up There will be no feeling from either Leads at this point as the intensity alw...

Страница 23: ...ity level The program will run for a total of 30 minutes with alternating treatment parameters for maximum clinical effect The device will shut off when the 30 minutes is complete Two buttons on the device control the intensity Increase and Decrease The intensity defaults to zero when the device is powered on Increase the intensity by pressing the up arrow on the screen until you feel a comfortabl...

Страница 24: ...m the Foot Bath After use dry the Pads and store There is no need to disconnect the Pads from the lead wires between sessions Treatment Frequency It is recommended that you perform 1 session per day as needed until symptoms improve Program Parameters Channel Single Output Maximum 48V peak value across 500 Ohm load Waveform Bi phasic rectangular Mono phasic Pulse Treatment Time 30mins Programs 1 ...

Страница 25: ...Hand Frequency 80Hz Waveform Biphasic Rectangular Phase 2 13 Minutes Pulse Width 0 5ms Foot Hand Frequency 8Hz Waveform Mono phasic Pulse Phase 3 13 Minutes Pulse Width 5 0ms Foot Pulse Width 3 0ms Hand Frequency 7 83Hz Waveform Biphasic Rectangular Program Parameters continued ...

Страница 26: ...rom zero to the max When the battery charging has completed the bar stops cycling and remains at maximum to indicate full capacity Remove the charging cable and adapter from the device when charging is completed Although the display fades as the battery runs down the strength of the output does not change until the warning is shown Troubleshooting Cleaning Clean the case and lead wires at least on...

Страница 27: ...y The manufacturer will not be held responsible for the results of maintenance or repairs by unauthorized persons The user must not attempt any repairs to the device or accessories Please contact the retailer for repair Opening of the equipment by unauthorized agencies is not allowed and will terminate any claim to warranty WARNING Do not modify this device without authorization of the manufacture...

Страница 28: ...www saebo com Saebo Rev 07 2021 ...