background image

Symptom

 

Possible Cause(s)

 

Remedy

 

No power or front 
panel lights and no 
sound. 

The power cable is not inserted 100% 
into AC input connector. 

Ensure that the AC cord(s) are fully in-
serted into the amplifier and that the wall 
outlet is active. 

 

Circuit breaker is open (AC outlet). 

Check the AC outlet circuit breaker and 
reset, if necessary, or contact your deal-
er. 

No audio output. 

Overheating, DC at output, Cata-
strophic failure 

The amplifier will turn off with the rear 
panel switch indicating O.  For any  but a 
catastrophic failure, the amplifier can be 
reset by removing the fault and complet-
ing the turn-on sequence again.  

Warm 

Normal operation 

 

Hot 

Normal operation 

 

 

 

 

Appendix A  Troubleshooting Guide 

 

If the 8300 should function abnormally during operation, please review the items in the following checklist.  Please be 
sure to thoroughly check all other connected components such as speakers and preamplifiers, as well as cables.  If the 
problem persists, please consult your dealer or distributor. 

Содержание 8300

Страница 1: ......

Страница 2: ...i ...

Страница 3: ...at The unit should be connected to a power supply outlet only of the voltage and fre quency marked on its rear panel The AC power cord should be routed so that it is not likely to be walked on or pinched especially near the plug convenience receptacles or where the cord exits from the unit Clean unit only as recommended in this instruction manual The unit s AC power cord should be unplugged from t...

Страница 4: ...service or updating the original packaging will best protect the unit from shipping damage In order to achieve the fullest flexibility and enjoyment from your SAE 8300 we recommend that you read this manual in full before connecting the unit to your audio system Warning Each channel of the 8300 is a balanced bridge amplifier thus the negative speaker ter minal is NOT a ground and cannot be connect...

Страница 5: ...gn with separate and independent power transformers power switches and line cords for each channel bank 2 High temperature Class F rated toroidal transformers 3 Dual temperature sensors and low speed cooling fan to maintain proper operating temperatures 4 Four layer circuit boards used throughout each with separate power and ground planes 5 Current feedback for improved amplifier control and virtu...

Страница 6: ...ugh visual inspection and are then tested in a bench reference ampli fier The tested assembled circuit boards are then installed in a new 8300 and the whole unit is tested for every func tion and parameter The unit is put on a burn in torture rack to test for any possible component failures The amplifier then undergoes a critical listening and functional test The unit has all remaining chassis com...

Страница 7: ...inates when the amplifier exits the STANDBY Mode 2 STANDBY SWITCH After the rear panel MAIN POWER switch es are turned on touch the front panel button to exit the standby mode and enter the operational mode Press again to return to STANDBY 2 1 2 ...

Страница 8: ...o connect each amplifier bank to an appropriate AC power source 7 FAN OUTLET Forced air used for cooling exits the amplifier here 8 VOLTAGE INDICATORS The 8300 amplifier is equipped with circuitry that automatically detects the AC voltage and sets the amplifier appropriately These indicators show the discovered voltage 120VAC is shown for line voltage of 100 to 130V 240VAC is shown for 200 to 260V...

Страница 9: ...ource device down all of the way Turn on SAE 8300 s MAIN POWER switches located on the rear panel When the end of the switch with indicating ON is depressed that half of the amplifier is in the STANDBY mode When in standby the amplifier draws less than 1 watt from the wall outlet Touch the front panel power button Both the switch and the SAE logo illuminate After a wait of about 45 seconds the sof...

Страница 10: ...tput Cata strophic failure The amplifier will turn off with the rear panel switch indicating O For any but a catastrophic failure the amplifier can be reset by removing the fault and complet ing the turn on sequence again Warm Normal operation Hot Normal operation Appendix A Troubleshooting Guide If the 8300 should function abnormally during operation please review the items in the following check...

Страница 11: ...n 8 ohms 4 ohms 20 Hz 20 kHz 0 01 THD 300 WRMS 450 WRMS 1 kHz 0 01 THD Watts 350 WRMS 500 WRMS 1 kHz 1 THD 360 WRMS 490 WRMS CEA 2006 1 kHz Burst Power 500 WRMS 750 WRMS Distortion THD N 20 Hz 20 kHz 0 03 0 03 THD N at 1 kHz 1W 0 005 0 005 Intermodulation Distortion SMPTE or Twin tone Less than 0 03 Frequency Response 0 3dB 5 Hz to 150 kHz 8 Ω Damping factor 600 at 100 Hz Signal to noise ratio 125...

Страница 12: ...ty is transferable to subsequent purchasers as long as all Optional Extended Warranty conditions are met Transferability The above warranties are transferable to subsequent owners as long as all the conditions are met under the Optional Extended Warranty Program The warranty is not transferable if the unit s was originally purchased from an unauthor ized seller The above warranties do not apply if...