background image

A. Blocked base valve.
B. Rotor worn or obstructed.

C. Insufficient suction pipe diameter.
D.Make sure the rotation is in the right

direction.

A. Clean the base valve.
B. Replace the rotor or eliminate the

obstruction.

C. Replace the pipe with a wider one.
D. Invert two supply cables

8. The pump produces insufficient

flow.

A. Excessively low suction pressure.
B. Suction pipe or pump partly obstructed

with impurities.

B. Clean the suction pipe and the pump

9. The pump flow is not constant.

A. Loss of suction pipe
B. Base or retention valve faulty or

blocked partly open.

A. Eliminate the problem
B. Repair or replace the faulty valve.

10. The pump turns the opposite

way when turned off

A. Check that the pump and the pipes are

properly fixed.

B. The pump shakes.

C. Air in the pump or suction manifold
D. Pump alignment not correct.

A. Block the loose parts.

B. Reduce the suction height and control

the load losses. Open the suction valve.

C. Purge the suction pipes and the pump.
D. Repeat the indications of section 7.2.

11. The pump vibrates with noisy

operation.

Faults

Checks

Solutions

15- CONNECTION FOR MOTORS

ENGLISH

17

230 V

400 V

TRIANGLE connection

STAR connection

3~230/400 V

1~230 V

Line

Line

manual V-nox 2010_A5  21/12/10  11:00  Página 19

Содержание V-NOX 300

Страница 1: ...ICELULARES V NOX 300 V NOX 300 V NOX 400 V NOX 400 V 1 2 3 V 1 2 3 VAT 127 VAT 127 VAT 163 VAT 163 VAT 205 VAT 205 INSTRUCCIONES PARA LA INSTALACION Y EL MANTENIMIENTO INSTALLATION AND MAINTENANCE MAN...

Страница 2: ...s BOMBAS SACI S A Ctra Matar Km 629 Pol Ind Rib C P 08911 BADALONA BARCELONA E d clarons sous notre responsabilit exclusive que les produits auxquels cette d claration se r f re sont conformes aux dir...

Страница 3: ...as de proyecto y de fabricaci n est n a la vanguardia y se distinguen por las prestaciones particulares que garantizan el m ximo rendimiento con absoluta fiabilidad y solidez Se pueden emplear en situ...

Страница 4: ...as sensoriales o mentales reducidas o con falta de experiencia y conocimiento a menos que sean supervisados o instruidos por una persona responsable de su seguridad Los ni os deben ser supervisados pa...

Страница 5: ...as de las tuber as deben estar posicionadas paralelas a las bridas de la bomba A fin de reducir al m nimo el ruido se aconseja montar juntas antivibraci n en las tuber as de aspiraci n y de alimentaci...

Страница 6: ...esponde a la que figura en la placa disponer la conexi n de los cables a la placa de bornes con prioridad del cable de tierra 8 4 COMPROBAR QUE LA INSTALACION DE TIERRA ESTE EN CONDICIONES EFICACES Y...

Страница 7: ...sivo n mero de arranques a la hora La cantidad m xima admisible es la siguiente 11 2 PELIGRO DE HIELO Si la bomba permanece inactiva por un largo periodo a una temperatura inferior a 0 C es necesario...

Страница 8: ...n las bombas 14 BUSQUEDA DE AVERIAS Y SOLUCIONES ESPA OL 6 A Verificar los fusibles de protecci n B Verificar las conexiones el ctricas C Verificar que el motor est alimentado A Si est n quemados sust...

Страница 9: ...erificar el calibrado de la protecci n C Verificar el estado de los cojinetes D Controlar la velocidad de rotaci n del motor A Ventilar adecuadamente el local donde est instalada la bomba B Efectuar e...

Страница 10: ...de retenci n defectuosa o bloqueadas en posici n de parcial abertura A Eliminar el inconveniente B Reparar o sustituir la v lvula defectuosa 10 La bomba gira al contrario al apagarla A Verificar que l...

Страница 11: ...icaciones y o si se emplean en sectores no aconsejados o que no se cumplan otras disposiciones citadas en este manual Cuando el producto haya sido desmontado total o parcialmente sin expresa autorizac...

Страница 12: ...ufacturing features are at the forefront of technology and stand out thanks to the particular services that guarantee maximum output with total reliability and solidity They may be used in a wide vari...

Страница 13: ...ncluding children with physical sensory or mental capabilities or lack of experience and knowledge unless they are supervised and instructed by a person responsible for their safety Children should be...

Страница 14: ...be fitted to the uptake and supply pipes 7 3 It is highly recommended to install the pump as close as possible to the liquid to be pumped It is best to use a suction pipe with a larger diameter than...

Страница 15: ...rect state and that a suitable connection can be carried out 8 5 The pumps must always be connected to an exterior switch 8 6 Motors must be protected with adequate motors suitably calibrated in relat...

Страница 16: ...ber of times each hour The maximum admissible number is as follows 11 2 Danger of icing If the pump is inactive for a long time at a temperature of under 0 C the whole of the pump housing must be empt...

Страница 17: ...s that use the pumps 14 TROUBLESHOOTING A Check the protection fuses B Check the electrical connections C Make sure the motor is receiving power A If they are burned replace them B If the problem is s...

Страница 18: ...perature is not too high B Check the protection calibration C Check the state of the bearings D Check the motor speed rotation A Suitably ventilate the premises where the pump is installed B Calibrate...

Страница 19: ...etention valve faulty or blocked partly open A Eliminate the problem B Repair or replace the faulty valve 10 The pump turns the opposite way when turned off A Check that the pump and the pipes are pro...

Страница 20: ...f it is used in unadvisable sectors or ones that fail to comply with the provisions mentioned herein When the product has been dismantled totally or partially without express authorisation The Guarant...

Страница 21: ...ues de projet et de fabrication sont l avant garde et se distinguent par les prestations particuli res qui garantissent un rendement maximum avec une fiabilit et une solidit absolues Elles peuvent tre...

Страница 22: ...physiques sensorielles ou mentales ou le manque d exp rience et de connaissances sauf s ils sont surveill s et instruit par une personne responsable de leur s curit Les enfants doivent tre surveill s...

Страница 23: ...les tuyaux d aspiration et d alimentation 7 3 Il est tr s recommand d installer la pompe le plus pr s possible du liquide pomper Il convient d utiliser un type d aspiration d un diam tre sup rieur ce...

Страница 24: ...connexion ad quate peut tre r alis e 8 5 Les pompes doivent toujours tre connect es un interrupteur ext rieur 8 6 Les moteurs doivent tre prot g s avec des protections de moteurs ad quates calibr es...

Страница 25: ...tropompe un nombre excessif de d marrages par heure La quantit maximale admissible est la suivante 11 2 Danger de gel Si la pompe reste inactive pendant longtemps une temp rature inf rieure 0 C il est...

Страница 26: ...les pompes 14 RECHERCHE DE PANNES ET SOLUTIONS A V rifier les fusibles de protection B V rifier les connexions lectriques C V rifier que le moteur est bien aliment A S ils sont br l s les remplacer B...

Страница 27: ...lev e B V rifier le calibrage de la protection C V rifier l tat des coussinets D Contr ler la vitesse de rotation du moteur A Ventiler de fa on ad quate le local o la pompe est install e B Effectuer...

Страница 28: ...bloqu e en position d ouverture partielle A liminer l inconv nient B R parer ou remplacer la valve d fectueuse 10 La pompe tourne en sens contraire au moment de l arr ter A V rifier que la pompe ou l...

Страница 29: ...t utilis es dans des secteurs d conseill s ou qui ne respecteraient pas d autres dispositions mentionn es dans le pr sent manuel Lorsque le produit aura t d mont totalement ou en partie sans autorisat...

Страница 30: ...ges ovais As suas caracter sticas de projecto e de fabrico est o na vanguarda e destacam se pelo desempenho particular que garante o m ximo rendimento com absoluta fiabilidade e solidez Podem ser util...

Страница 31: ...as com capacidades f sicas sensoriais ou mentais ou a falta de experi ncia e conhecimento a menos que sejam supervisionados e orientados por uma pessoa respons vel pela sua seguran a As crian as devem...

Страница 32: ...s tubos de aspira o e de compress o 7 3 muito recomend vel instalar a bomba o mais perto poss vel do l quido a bombear conveniente utilizar um tubo de aspira o num di metro superior ao da boca de aspi...

Страница 33: ...e efectuar uma liga o adequada 8 5 As bombas devem estar sempre ligadas a um interruptor exterior 8 6 Os motores devem estar protegidos com protec es de motores adequadas e devidamente calibradas no q...

Страница 34: ...mero de arranques excessivo por hora A quantidade admiss vel a seguinte 11 2 Perigo de gelo Se a bomba permanecer fora de servi o durante um longo per odo de tempo a uma temperatura inferior a 0 C ser...

Страница 35: ...s e das instala es que integram as bombas 14 POSS VEIS AVARIAS E SOLU ES A Verificar os fus veis de protec o B Verificar as liga es el ctricas C Verificar se o motor recebe tens o A Substituir os fus...

Страница 36: ...ente demasiado alta B Verificar a calibra o da protec o C Verificar o estado dos rolamentos D Controlar a velocidade de rota o do motor A Ventilar bem o local onde a bomba est instalada B Efectuar a c...

Страница 37: ...defeituosas ou bloqueadas na posi o de abertura parcial A Eliminar o inconveniente B Reparar ou substituir a v lvula defeituosa 10 A bomba roda ao contr rio ao ser desligada A Verificar se a bomba ou...

Страница 38: ...u nos casos de utiliza o em sectores n o aconselhados ou de n o cumprimento de outras disposi es citadas neste manual Quando o produto tenha sido desmontado total ou parcialmente sem autoriza o expres...

Страница 39: ...37 DATOS T CNICOS TECNICAL DATA DONN ES TECHNIQUES manual V nox 2010_A5 21 12 10 11 00 P gina 39...

Страница 40: ...6 77 91 105 116 130 H max 11 11 11 11 11 11 11 11 H min V NOX 403 V NOX 404 V NOX 405 V NOX 406 V NOX 407 TIPO TYPE 1 5 1 5 1 5 1 5 1 5 Q 21 21 21 21 21 35 46 58 70 82 H 12 14 18 23 28 34 6 45 56 8 67...

Страница 41: ...09 V NOX 310 TIPO TYPE 38 38 38 38 38 38 38 38 A 162 187 212 237 262 286 311 335 B 200 225 250 275 300 325 350 375 C 531 555 579 629 653 718 742 781 D 133 133 133 133 133 133 133 133 E 182 182 182 182...

Страница 42: ...15 14 13 8 15b 12 11 10 4 3 2 1 7 6 5 18 19 20 22 9 21 1 2 23 24 25 28 27 26 29 30 31 32 33 34 37 38 36 35 39 40 42 41 43 45 44 46 49 47 48 9 V NOX 300 400 40 manual V nox 2010_A5 21 12 10 11 00 P gi...

Страница 43: ...LANGE SEAL 11 4 DRIVE HOUSING MOTOR FLANGE BOLT M8x25 PRIMING BOLT WASHER PRIMING BOLT 1 4 MOTOR COVER BOLT MOTOR COVER WASHER MOTOR FRONT COVER LOWER BEARING ROTOR WITH SHAFT UPPER BEARING TERMINAL C...

Страница 44: ...ring you the best quality 18 CERTIFICAT D ESSAIS Toutes nos pompes passent un strict contr le de qualit qui nous permettent de garantir un fonctionnement optimal et une grande fiabilit Absolument TOUT...