
- 11 -
Hot Pod CF
Manual
5.5 Change of the pneumatic spring
Danger of injury when using a pneumatic spring
->
Under no circumstances you should undo the
pneumatic spring. Pneumatic springs have an
extremely high internal pressure
.
->
Prior to disposal the pneumatic spring must not
be under pressure.
->
Fasten the column hood
2
again completely.
After several turns it will require more strength to
turn the column hood.
->
Loosen the column lock
1
.
->
Extend the column completely.
->
Lock the column lock 1 again.
->
Turn the Hot Pod CF upside down.
->
Unscrew and remove the column
hood
2
.
->
Change the pneumatic spring
3.
!
Danger
Содержание Hot Pod CF
Страница 1: ...Hot Pod CF Manual Benutzerinformation Tripod Stativ...
Страница 5: ...1 Hot Pod CF Benutzerinformation...
Страница 33: ...29 Hot Pod CF Manual...
Страница 34: ...Manual Hot Pod CF www sachtler com...