6. INSTALLATION
21
80mm
160mm
520mm
600mm
The central vacuum unit should be installed in a well-aired location providing easy access, far away
from any heat source. Similarly, it should be located close to an electrical supply point. It should be
placed at a height of approximately 0.6m from the oor which will allow for the emptying of the bin. It is
advisable to leave a space on either side of the unit to permit easy handling of the unit.
Wherever possible the central vacuum should always be located on a supporting wall or a concrete
wall to avoid vibrations. Once the location has been chosen, x the bracket to the wall and hang the
central vacuum unit onto the bracket.
Soporte de la central
Soporte pared
131m
m
FIXING THE CENTRAL VACUUM UNIT TO THE WALL
ELECTRICAL CONNECTION AND LOW VOLTAGE LINE (TO
THE VACUUM INLET VALVES)
MICRO
LINE
230V
An appropriate plug socket and a plug of the Schuko type is required to connect the central vacuum to
the electrical supply. Electrical connections should be made as indicated below.
Electrical power cable
Schuko-style plug
(230V - 50Hz) (230V-50Hz)
Vacuum inlet valve
Low-voltage line
(to connect to the vacuum
inlet valves)
WARNING: Ensure that the electrical supply corresponds to the power rating which appears on the
appliance’s rating plate. In the event that the power cable is damaged, you should only replace it with