The Sabroe hand-operated oil pump, part no. 3141-155, is recommended as prelubrication
pump, see Table 14. For prelubrication: use clean fresh refrigeration oil of the same type as
the one in the compressor, and pump as follows:
Compressor type
Pump strokes with Sabroe
hand-operated oil pump
Estimated amount of oil
Litres
SMC 104-106-108
TSMC 108
HPC 104-106-108
HPX 704-706-708
approx. 35
3.5
SMC 112-116, TSMC 116
HPC 112-116
HPX 712-716
approx. 45
4.5
Table 14
The heating rod in the crankcase must be switched on for at least 6-8 hours before compressor
start-up in order to boil out any refrigerant from the compressor oil. At the same time, the suc-
tion stop valve must be open.
Check the oil level in the crankcase. The oil level must always be visible in the oil sight glass.
A hand-operated oil pump
connected to the oil charging valve, pos. B, can be used for the
first as well as the following oil charges. See
3.8 Valves for operation of compressor.
Fig. 18: Hand-operated oil pump
Note:
When the evaporating pressure (P
E
) is higher than 2 bar, the pressure must be relieved
before oil charging. On HPC and HPX compressors, P
E
is
always
higher than 2 bar.
4.13
Shaft seal
The rotating sealing surface on the mechanical shaft seal is made of a soft material, which will
tend to wear during operation. Therefore, the shaft seal must be checked regularly for tight-
ness and wear in accordance with the service intervals applying to the compressor.
T0177131_0 V15
Hose connects to nipple 1349-344
already fitted on valve 4E/4F next to
the external oil filter.
Nipple 2312-045
+nipple 1349-344
Hose 2315-055
Optional hand-
operated oil pump
Содержание HPC 100 Mk 4 LL