background image

1. Product Description

  

ACCESS/ROTAMAX PRO KL 

Design

• Omni-directional lighting system

• Stainless steel body and head

• Quadruple spray

• Push button

• Easy grip coating

2. Specifications

6. Replacement of Rotor

Dealer

Manufactured by

SABLE INDUSTRIES INC.

100 Campbell Avenue, Suite 5

 

Kitchener, Ontario, N2H 4X8

 

TEL:+1-800-368-8106

FAX:+1-519-579-9323

Email: [email protected]

 

PPIS 103

3

 REV-

A

ACCESS/ROTAMAX PRO KL Series

KaVo

®  

& MULTIflex

® 

are the registered trademarks of Kaltenbach & Voigt GmbH CO. ,Germany.

CAUTION: U.S. Federal law resticts the use of this device to licensed professionals.(Rx Only)

10. Disclaimer

9. Sterilization

11. Quality and Service

 

Fig. 6

Fig. 7

Fig. 8

5. Changing Bur

3. Safety Notes

4. Installation

To install or remove handpiece, please follow the steps illustrated from Fig. 1 to Fig. 3 

(Please refer to the coupling manufacturers' instructions.)

Fig. 1 Install EZclick connector

Fig. 2 Rotate the connector to install

Fig. 3 Strip EZclick connector

2.8

 / 

40.5 P.S.I.

 

0.8

~

2.0 / 12.0

~

29.0 P.S.I.

Model

ROTAMAX PRO KL / ACCESS PRO KL

Connection

KaVo

® 

MUL

TIflex

®

Rotation Speed (rpm)

Bur size (mm)

(diameter / length)

Driving Air Pressure (bar)

Recommended Driving 

Air Pressure (bar) 

Spray Volume (ml/min)

W

ater Pressure (bar)

1.0~

3

.

0 / 14.5

~

43.5 P.S.I.

Glass Rod

>

5

0

T>300,000; M>350,000

Ø1.59~1.60 / T(19~25); M(16~21)

2

.

6

~

3

.

0 / 37.7

~

43.5 P.S.I.

Chip Air Pressure (bar)

Light system

*T: torque head; M: mini head; L: light support

**Chip air pressure must be greater than chip water pressure and both values need to be set at the same time 

7. Cleaning

   

1. Once handpiece is damage (ie deformed caused by hit) or improperly use (ie.

sterilized above suggested temperature), be sure not to continue using it.

2. Before operation, always make sure the product and its accessories meet the specified

requirements (ie drive air pressure. lubrication...etc).

3. Please contact our dealer or us with proof of purchase, whenever you have problems

such as abnormal vibration, exceeding temperature or unusual noise...etc.

4. Avoid contact between the instrument head and soft tissue (risk of burning due to the

press button heating up).

1. Follow the direction of the arrows shown in attached image (Fig.

4) to install or remove bur.

2. Put on protective gloves to reduce the risk of interactive

inflection, especially not to touch the used burs without proper

protection.

3. Make sure bur is tightly secured before operation, otherwise risks

of injury to doctors, patients or the third party could occur.

4. Bur must be complied with ISO requirement. Burs not in good

conditions such as being bent and damaged, or are deviated

from ISO standards and in improper length may decrease the

lifetime of the handpiece or even cause severe consequence

such as injury to people.

5. Do not press the button while bur is rotating, otherwise it could

harm internal parts.

1. Please contact local dealers and let the technicians replace the rotor.
2. Do not use unsuitable rotors or spare parts, otherwise could damage the handpiece and

result in severe consequence during treatment.

    

Do not immerse handpiece in disinfectant solution or water or an ultra-sonic cleaner.

1. Protective gloves should be worn every time hand piece is to be cleaned and

lubricated.
2. Detach the handpiece from the coupler and remove the bur.
3. Use clean cloth with mild cleaning solution to clean the handpiece surface carefully to
remove any residue.
4. Operate the handpiece at the chair-side for at least 20 seconds to purge fluids.

*Wash the han

d

piece and 

irrigation

 nozzle under running water following the procedures

 

below.

(Water condition:<38°C (100°F),

>

3.5L/min; water should be same

 

quality as drinking

 

water)

5.

    Cle

an the external surfaces of the handpiece with a soft

bristled toothbrush for 15 seconds or more.
6. Clean around the bur insertion hole for 15 seconds or more,
using an interdental brush (wire thickness 0.7mm)that conforms
to size 4 in ISO 16409.
7. Under appropriate lighting (natural office lighting), inspect the
handpiece for blood or other debris. If any visible debris remain, repeat the process 

until the handpiece is visually clean.

8.

Wipe the exterior of the handpiece clean using a cloth moistened with disinfectant or

 

ethanol with a concentration

 

of 60-90% (ie. Isopropyl)

8.

Lubrication and Maintenance

1.

Use dental handpiece lubrication oil for maintenance, any unspecified oil not

intended for lubricating handpieces could shorten the lifetime and harm human body.

2. To lubricate 500 series handpiece, put Spray Nozzle into nozzle of the lubrication oil

can (Fig. 6).Connect handpiece with the nozzle (Fig. 7) and inject lubrication oil for 2~3

seconds.

3. Be sure to lubricate the handpieces prior to sterilization and run the handpieces for

20~30 seconds to emit residual oil and dirt.

4. To lubricate handpiece chucks, put Shaft Spray Nozzle into nozzle of the lubrication oil

can and inject lubrication oil into the chuck (Fig. 8) for 1 second. It’s recommended to

lubricate chuck at least once a week and then proceeds step 2.

5. After unpacking and prior to first use, be sure to lubricate with oil and run the

handpieces in low rotation speed for 30 seconds and in full speed for 20~30 seconds to

emit residual oil.

Sable suggests sterilization in accordance with ISO 117373-2-2019
1.

Place handpiece in single-use sterile bag and proceed steam prevacuum

sterilization. Do not open the sterile bag before use in order to avoid contact infection.

2.

Use qualified sterilization equipment specified by the authority/government for

sterilization procedures.

3.

Do not use chemical steam nor immerse handpiece or cartridge/rotor in disinfectant

solution, otherwise could damage the handpiece and cause severe consequences.

4.

Sterilization holding time is a minimum of 4 minutes at 134

º

C. (drying time is 15

minutes).

 

 

 

 

1. Information in this operation manual were carefully reviewed. We cannot assume any

liability for any damage arising from improper use of the handpiece or from use of this

manual.

2. Products are subject to change without notice.
3. Indications for Use: PRO KL Series High Speed Handpieces are intended for removing

carious parts of tooth, proceeding cavity and crown preparations.

4. Please refer to the bar code on the packing box for manufacturing and expiration date.

All of our products have passed strict QC procedures before delivery. Please note that 

improper use or not using the recommended parts and accessories or modifying our 

products without our approval may shorten the lifetime of the product or cause damage. 

Please contact us or dealers with proof of purchase for consultation whenever you have 

any questions.

Fig. 4 Changing Bur

Fig. 5 Cleaning