background image

7

NATURAL GAS CONNECTION

The outdoor kitchen must be disconnected from the
natural gas supply piping system during any pressure

The outdoor kitchen must be isolated from the natural
gas supply piping system by closing all individual
shut-off valves during any pressure testing of the

testing of the system in excess of ½ PSIG (3.5 kPa).

WARNING

system equal to or less than ½ PSIG (3.5 kPa). 

Never connect the grill to an unregulated gas supply.

It is recommended that you use a certified or licensed
gas technician to make all natural gas connections.

Prior to construction, confirm with your dealer if any
permits are required to comply with the state and local 
codes for natural gas installation.

IMPORTANT

To allow proper heating performance of the grill and side
burner, confirm that your home natural gas supply
pressure is sufficient to maintain 4.0” W.C. manifold
pressure at each appliance (measured while each is in
operation).  A home natural gas supply pressure of
7”±1.5” W.C. entering each appliance regulator is
desirable to achieve 4.0” W.C. outlet pressure at each
appliance regulator.  If the grill or side burner are
operating at a gas pressure lower than 4.0” W.C., the
resulting BTU rate for each will decrease resulting in
poor heating performance.  Decreased gas pressure
can also make each appliance more susceptible
to blow-out by wind.  A certified gas technician can confirm
if your home’s natural gas supply pressure is acceptable.   

CAUTION

The grill and side burner provided with this outdoor kitchen
are set for use with natural gas.  Both appliances are
designed for conversion to LP gas also.

CONVERSION TO LP GAS MUST BE PERFORMED BY
A CERTIFIED GAS TECHNICIAN.

LP conversion kit model K00AA4615 must be used (sold
separately).  This conversion kit is to be used ONLY with
SABER EZ Outdoor Kitchens.

Step 1:  Correctly Sizing the Natural Gas Supply Line

In most cases, a pipe diameter of ½” to ¾” is sufficient
to connect your outdoor kitchen to your home’s natural gas
supply system.  The correct pipe size depends on 
the following:
     
     

     1. the overall length of your home’s natural gas supply
         pipe run
     2. the connection point of your outdoor kitchen into your
         home’s natural gas supply system with respect to
         placement of natural gas appliances in your home
     3. the desired distance of the outdoor kitchen from your
         home’s natural gas supply
     4. the combined total BTU rate of all the natural gas
         appliances in your home.

A certified gas technician will be able to recommend the
appropriate gas pipe size and length to connect your outdoor
kitchen to your home gas supply.  The combined BTU rate
of the grill and the side burner in your outdoor kitchen is
42,000 BTU/hr.

Step 2:  Placement of the Manual Shut-off Valve

It is recommended that a manual shut-off valve that is
sized correctly for the gas supply pipe be installed outside
the kitchen enclosure.  This valve will allow safe access to
shut off the natural gas supply to the outdoor kitchen in the
event of an emergency.  A convenient location for the safety
valve is at the rear of the kitchen enclosure in proximity to the 
grommet in the rear wall.  This allows for easy access to
connect the gas piping in the enclosure to the safety valve
(see image below).

If a gas supply stub-up is used inside the kitchen enclosure,
an external shut-off valve close to the grill is still recommended.

Manual Shut-off Valve

Содержание EZ I Series

Страница 1: ... www sabergrills com patents If you have questions or need assistance during assembly please call 1 888 947 2237 1 888 947 SABER For support and to register your grill please visit us at www sabergrills com R Series 1 CONVERSION TO LP GAS MUST BE PERFORMED BY A CERTIFIED GAS TECHNICIAN LP Conversion Kit Model K00AA4615 must be used Sold separately Conversion kit to be used ONLY with SABER EZ Outdo...

Страница 2: ...can help you understand if your city or county requires any permits for construction and how to obtain them prior to delivery Please review this entire manual to ensure the safe and successful assembly of your outdoor kitchen WARNING THIS GRILL IS FOR OUTDOOR USE ONLY DANGER If you smell gas 1 Shut off gas to the appliance 2 Extinguish any open flame 3 Open lid 4 If odor continues keep away from t...

Страница 3: ...afety hazard The pressure regulator supplied must be used and replacements must be those specified by the appliance manufacturer WARNING Do not attempt to repair or alter the natural gas regulator for any assumed defect Any modification to this assembly will void your warranty and create the risk of a gas leak and fire Use only authorized replacement parts supplied by manufacturer Table of content...

Страница 4: ...ewalks to make sure your outdoor kitchen will pass through unobstructed You may have to remove a gate or part of a fence to allow adequate width clearance Allow at least the width of the island plus 12 If the delivery route will require a 90º turn check the measurements at the turn to ensure the outdoor kitchen will fit Notify your dealer prior to delivery if there are stairs in the path to the con...

Страница 5: ...chen grill and all accessories The weight of 500 lbs can be used for this evaluation If you are unsure have a contractor or structural engineer examine your deck to determine whether it can bear the load The image below details the actual dimensions of the outdoor kitchen base and counter top Dimensions are the same for both the I series kitchen with ice chest and R series kitchen with LOCATION PL...

Страница 6: ...se to power the grill lights and the refrigerator R series kitchens only The GFCI outlet rating is 125V 60Hz 15A This outlet can be connected to your house power by either of the using a grounded outdoor rated extension cord SJTW rating less than 100ft This cord can connect to the A Saber EZ Outdoor Kitchen external sealed outlet accessory can be purchased at your local retailer for additional ele...

Страница 7: ...nversion to LP gas also CONVERSION TO LP GAS MUST BE PERFORMED BY A CERTIFIED GAS TECHNICIAN LP conversion kit model K00AA4615 must be used sold separately This conversion kit is to be used ONLY with SABER EZ Outdoor Kitchens Step 1 Correctly Sizing the Natural Gas Supply Line In most cases a pipe diameter of to is sufficient to connect your outdoor kitchen to your home s natural gas supply system...

Страница 8: ...gas supply line 18 L 2 3 8 OD flexible coated stainless steel gas supply line 12 L 3 3 8 OD flexible coated stainless steel gas supply line 60 L 4 SAE 45 union tee male 3 8 tube OD MFL 5 2 Adapter 1 2 NPT Male x 3 8 SAE 45 MFL Gas connection components are sold separately Alternate gas components may be used as recommended by your gas technician All pipe thread connections should be sealed using p...

Страница 9: ...gly recommend using a SABER stainless steel polish with a micro fiber cloth to prevent smudging and surface rust Clean internal parts of the grill regularly as determined by the amount of use and foods cooked The entire grill should be cleaned at least once a year In addition keep the area around your grill clear and free from combustible materials gasoline and other flammable vapors and liquids Do ...

Страница 10: ... R SERIES BACK PANEL E 1 R SERIES COUNTER TOP F 1 R SERIES BASE BOARD G 1 R SERIES FRONT PANEL H 1 R SERIES FLOOR PANEL I 1 GRILL SUPPORT BRACKET KIT 1 K HARDWARE KIT GROMMET L 1 QUICK START GUIDE R SERIES J ELECTRICAL OUTLET PANEL NOT PICTURED 1 R Series Parts List and Diagram EXTERNAL ELECTRICAL OUTLET COVER PANEL GFCI ELECTRICAL KIT 1 1 PRODUCT GUIDE ENGLISH PRODUCT GUIDE SPANISH PRODUCT GUIDE ...

Страница 11: ...he part in question be returned for inspection and analysis Requested parts should be returned to Saber freight pre paid by the consumer WARRANTY LIMITATIONS EXCLUSIONS This warranty excludes units purchased for use in all types of commercial and or community use locations such as restaurants hotels catering operations food service establishments condominium apartment complexes rental properties a...

Страница 12: ...used by lack of maintenance neglect in following the manufacturer s care and usage instructions grease fires animals and insects Any damage resulting from the commercial and or community use of this product Retail display models are generally sold AS IS If you have purchased a display model please be advised that it is sold AS IS and that it is subject to the following warranty exclusions Any exte...

Страница 13: ...itchen component grill side burner or refrigerator date of purchase and the accurate description of the problem We look forward to assisting you Date of Purchase Dealer Where You Purchased Your SABER EZ Outdoor Kitchen Dealer Phone Number Model Numbers located on the cover of the product guide or rating label for each kitchen component grill side burner and refrigerator Serial Numbers located on t...

Страница 14: ......

Отзывы: