4.  WARNING!

 LOCATIONS TO AVOID:

 

  IN AN AREA WHERE THE TEMPERATURE MAY FALL BELOW 32°F (0°C) OR 

RISE ABOVE 104°F (40°C) 

  IN  FRONT  OF  FORCED  AIR  DUCTS  USED  FOR  HEATING  AND  AIR 

CONDITIONING, NEAR CEILING FANS, OR OTHER HIGH AIR FLOW AREAS. 

  DIRECTLY ABOVE ANY GAS APPLIANCE. 

  IN  CLEANING  SUPPLY  ROOMS:  CHEMICALS  USED  IN  HOUSEHOLD 

CLEANING AND PAINTING SUPPLIES CAN CAUSE NUISANCE ALARMS. 

  IN  HAZARDOUS  LOCATIONS:    THIS  DETECTOR  IS  NOT  SUITABLE  FOR 

INSTALLATION IN A HAZARDOUS LOCATION, AS DEFINED IN THE NATIONAL 
ELECTRICAL CODE. 

 

5.  WARNING!  

CHEMICALS TO AVOID:

 

DO NOT EXPOSE THE DETECTOR TO CHEMICALS THAT WILL DEGRADE THE 
SENSOR OR CAUSE PERMANENT DAMAGES.  

  SILICONES  FOUND  IN  LUBRICANTS,  COSMETICS,  AND  CLEANING 

PRODUCTS 

  ORGANO-METALLIC COMPOUNDS FOUND IN SOME FUELS 

  ACETYLENE FOUND IN OXY-FUEL WELDING  

 

6.  INSTALLATION INSTRUCTIONS

NOTE!

 

REVIEW SECTION 3, 

RECOMMENDED LOCATIONS OF DETECTORS 

AND

 

SECTION  4, 

LOCATIONS  TO  AVOID,

  PRIOR  TO  INSTALLING  YOUR 

DETECTOR. 

The proper power for the STCH-1000 series natural (methane) gas detectors is 120 
volt single phase, supplied from a non-switchable circuit which is not protected by a 
ground fault interrupter. 

CAUTION!

   

TURN  OFF  THE  MAIN  POWER  TO  THE  CIRCUIT  BEFORE 

WIRING THE DETECTORS STCH-1000HW and STCH-1000HWR. 

STCH-1000HW  and  STCH-1000HWR  should  be  installed  on  a  U.L.  listed  or 

recognized junction box.  All wiring should be performed by a licensed electrician. 

 

a. WIRING REQUIREMENTS 

Installation of STCH-1000:

 

The  model  STCH-1000  is  a  direct  plug  in  unit.    Be  sure  that  the  outlet  on  which 
you  install  the  detector  is  not  controlled  by  a  switch  and  that  the  detector  is  not 
obstructed by drapes etc. 

 

Содержание STCH-1000

Страница 1: ... option ELECTRICAL RATING 120VAC 60Hz 5 Watts PSM 011 Natural Methane Gas Detector 12 VDC direct wire in with relay ELECTRICAL RATING 12VDC 5 Watts IMPORTANT READ ALL INSTRUCTIONS BEFORE INSTALLATION AND SAVE THIS MANUAL FOR FUTURE REFERENCE WARNING THIS DETECTOR WILL ONLY INDICATE THE PRESENCE OF NATURAL METHANE GAS AT THE SENSOR NATURAL METHANE GAS MAY BE PRESENT IN OTHER AREAS THIS DEVICE IS NO...

Страница 2: ...d is factory calibrated to sound an alarm that meets UL1484 standard The L E L Lower Explosive Level of natural methane gas is 5 in volume and the alarm level of this detector is set at 10 25 of the L E L Lower Explosive Level When the alarm is triggered the red light and buzzer will stay on for a minimum of 5 minutes If natural methane gas levels persist beyond the calibrated level the detector w...

Страница 3: ...hat gas operated appliances are installed see Figure 1 Since natural methane gas is lighter than air 1 0 56 the greatest concentration of gas will be immediately under the ceiling Mount detectors on the wall with the top edge of the detector at a minimum of 6 15cm and a maximum of 12 30 5 cm below the ceiling and at least 2 feet 60 1 cm from any corner see Figure 2 If the ceiling is sloped or high...

Страница 4: ...METALLIC COMPOUNDS FOUND IN SOME FUELS ACETYLENE FOUND IN OXY FUEL WELDING 6 INSTALLATION INSTRUCTIONS NOTE REVIEW SECTION 3 RECOMMENDED LOCATIONS OF DETECTORS AND SECTION 4 LOCATIONS TO AVOID PRIOR TO INSTALLING YOUR DETECTOR The proper power for the STCH 1000 series natural methane gas detectors is 120 volt single phase supplied from a non switchable circuit which is not protected by a ground fa...

Страница 5: ...he black wire is connected to 120VAC Hot line and the white wire is connected to the Neutral line see Figure 3A Installation of PSM 011 PSM 011 has two sets of wire harness DC power and relay For the DC Power Quick Connector wiring connection the red wire is connected to 12VDC and the black wire is connected to 0VDC see Figure 3B Connections on the relay The Relay Quick Connector has three wires t...

Страница 6: ...et above the floor Pull the Quick Connector through the center hole in the mounting plate Plug the mating halves of Quick Connector with the same color of wires together Slide the detector on the mounting plate to the lock position Turn on the power and the green POWER ON indicator should be lit for receiving power After installation TEST your detector by pressing and holding the TEST RESET button...

Страница 7: ...alibrated level 10 25 L E L the detector will sound beep beep and turn on the red LED If this dangerous condition lasts for 4 seconds the natural methane gas detector will latch on alarm mode for 5 minutes with the red LED turning on and the buzzer sounding continuously During this 5 minutes period the detector will cease sensing gas concentrations and the green LED will flash to indicate the same...

Страница 8: ...y the Gas Company check to see if one of the reasons listed in section 4 may have caused the alarm Some solvents used in chemical cleaning agents paints varnishes and the furniture refinishing process and some propellants used in aerosol hair spray and air fresheners can cause the detector to alarm if they are used in close proximity to the detector for extended periods of time Gasoline or other f...

Страница 9: ... methane gas STCH 1000 series A C powered detectors will not operate if the A C power has been cut off such as by an electrical fire a tripped circuit breaker or an open fuse These detectors must be tested regularly to make sure that they are receiving power and operating properly Detectors cannot sense natural methane gas that does not reach the detector and therefore detectors may not detect nat...

Страница 10: ...m to leave your home when they hear it Practice an escape drill at least once every six months Practice allows you to test your plan before an emergency You may not be able to reach your children in an emergency so it is important that they know what to do b WHAT TO DO WHEN THE ALARM SOUNDS Leave immediately by your escape plan Every second counts so don t waste time getting dressed or picking up ...

Страница 11: ...r if it fails to operate due to improper maintenance or inadequate A C D C electrical power THE LIABILITY OF PATRICK PLASTICS INC OR OF ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS ARISING FROM THE SALE OF THIS NATURAL METHANE GAS DETECTOR OR UNDER THE TERMS OF THIS LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF THE REPLACEMENT OF THE NATURAL METHANE GAS DETECTOR IN NO CASE SHALL PATRIC...

Отзывы: