S+S Regeltechnik 2003-4161-1100-001 Скачать руководство пользователя страница 1

HYGRASGARD

® 

KFTF - 20 - VA   

ID

D G F r

Herzlichen Glückwunsch!  
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!  
You have bought a German quality product.
Félicitations !    
Vous avez fait l’acquisition d’un produit allemand de qualité.
Примите наши поздравления !   
Вы приобрели качественный продукт, изготовленный в Германии.

D

  

Bedienungs- und Montageanleitung

Kanal- Feuchte- und Temperaturfühler (± 1,8 %),  
incl. Montageflansch, kalibrierfähig,  
mit Mehrbereichsumschaltung und aktivem ⁄ passivem Ausgang

G

  

Operating Instructions, Mounting & Installation

Duct humidity and temperature sensors (± 1,8 %),  
including mounting flange, calibratable,  
with multi-range switching and active ⁄ passive output

F

  

Notice d’instruction

Sonde d’humidité et de température (± 1,8 %),  
pour montage en gaine, y compris bride de montage, étalonnable,  
avec commutation multi-gamme et sortie active ⁄ passive

r

  

Руководство по монтажу и обслуживанию

Датчик влажности и температуры канальный (± 1,8 %),  
вкл. присоединительный фланец, калибруемый,  
с переключением между несколькими диапазонами  
и активным ⁄ пассивным выходом

KFTF - 20 - VAQ 

LCD  

KFTF - 20 - VA

6000-5050-0000-1XX   

50500-2020  V100

    05  ⁄  2020

S+S REGELTECHNIK GMBH 
PIRNAER STRASSE 20 
90411 NÜRNBERG ⁄ GERMANY

FON  +49 (0) 911 ⁄ 5 19  47- 0 
FAX  +49 (0) 911 ⁄ 5 19  47- 70

[email protected] 
www.SplusS.de

Содержание 2003-4161-1100-001

Страница 1: ...allation Duct humidity and temperature sensors 1 8 including mounting flange calibratable with multi range switching and active passive output F Notice d instruction Sonde d humidité et de température 1 8 pour montage en gaine y compris bride de montage étalonnable avec commutation multi gamme et sortie active passive r Руководство по монтажу и обслуживанию Датчик влажности и температуры канальный...

Страница 2: ...ousing with cable gland Boîtier avec presse étoupe Корпус с резьбовым кабельным вводом M20x1 5 M12 32 ø16 197 229 112 102 97 143 61 126 8 8 17 126 8 8 17 M20x1 5 M12 32 ø16 197 229 112 102 97 143 61 126 8 8 17 126 8 8 17 M20x1 5 M12 32 ø16 197 229 112 102 97 143 61 126 8 8 17 126 8 8 17 M20x1 5 M12 32 ø16 197 229 112 102 97 143 61 126 8 8 17 126 8 8 17 SF M Metall Sinterfilter Metal sinter filter ...

Страница 3: ...euchte 0 100 r H Ausgang entspricht 0 10 V oder 4 20 mA zulässige Luftfeuchte 95 r H nicht kondensierende Luft Abweichung Feuchte typisch 1 8 10 90 r H bei 25 C sonst 2 0 Ausgang Feuchte 0 10 V bei U Variante 4 20 mA bei I Variante TEMPERATUR Messbereich Temperatur Mehrbereichsumschaltung siehe Tabelle 35 35 C 35 75 C 0 50 C 0 80 C Ausgang entspricht 0 10 V oder 4 20 mA Umgebungstemperatur Lagerun...

Страница 4: ... 0 5 0 12 0 5 5 7 13 1 10 6 4 14 3 15 7 1 15 4 20 7 9 16 6 25 8 6 17 7 30 9 3 18 9 35 10 0 20 0 Temperaturtabelle MB 0 50 C C UA V IA mA 0 0 0 4 0 5 1 0 5 6 10 2 0 7 2 15 3 0 8 8 20 4 0 10 4 25 5 0 12 0 30 6 0 13 6 35 7 0 15 2 40 8 0 16 8 45 9 0 18 4 50 10 0 20 0 HYGRASGARD KFTF 20 VA Kanal Feuchte und Temperaturfühler 1 8 ID Typ Messbereich Anzeige Feuchte Temperatur Ausgang Display Feuchte Tempe...

Страница 5: ... Leiter Anschluss für Geräte ohne mit Display unbeleuchtet 4 Leiter Anschluss für Geräte mit beleuchtetem Display Bei der I Variante ist der Feuchte pfad zwingend anzuschließen Temperatur Messbereiche einstellbar DIP 1 DIP 2 35 75 C O N O N 35 35 C OFF OFF 0 50 C default OFF O N 0 80 C O N OFF 1 2 3 4 1 2 3 4 5 6 ON DIP C offset r H Stecker Display Kontakt seite UB GND UB 24V AC DC Ausgang Feuchte...

Страница 6: ...riante eine Einweggleichrichtung bzw Verpolungschutzdiode integriert Diese interne Einweggleichrichtung erlaubt auch den Betrieb mit AC Versorgungs spannung bei 0 10 V Geräten Das Ausgangssignal ist mit einem Messgerät abzugreifen Hierbei wird die Ausgangsspannung gegen das Nullpotenial O V der Eingangsspannung ge messen Wird dieses Gerät mit DC Versorgungsspannung betrieben ist der Be triebsspann...

Страница 7: ...ieses Gerät ist nur für den angegebenen Verwendungszweck zu nutzen dabei sind die entsprechenden Sicherheitsvorschriften des VDE der Länder ihrer Überwachungsorgane des TÜV und der örtlichen EVU zu beachten Der Käufer hat die Einhaltung der Bau und Sicherungsbestimmung zu gewährleisten und Gefährdungen aller Art zu vermeiden Für Mängel und Schäden die durch unsachgemäße Verwendung dieses Gerätes e...

Страница 8: ...ponding to 0 10 V or 4 20 mA Permitted humidity 95 r H non precipitating air Deviation in humidity typically 1 8 10 90 r H at 25 C otherwise 2 0 Output humidity 0 10 V for U variant 4 20 mA for I variant TEMPERATURE Measuring range temperature multi range switching see table 35 35 C 35 75 C 0 50 C 0 80 C output corresponding to 0 10 V or 4 20 mA Ambient temperature storage 35 85 C operation 30 80 ...

Страница 9: ... 0 12 0 5 5 7 13 1 10 6 4 14 3 15 7 1 15 4 20 7 9 16 6 25 8 6 17 7 30 9 3 18 9 35 10 0 20 0 Temperature table MR 0 50 C C UA V IA mA 0 0 0 4 0 5 1 0 5 6 10 2 0 7 2 15 3 0 8 8 20 4 0 10 4 25 5 0 12 0 30 6 0 13 6 35 7 0 15 2 40 8 0 16 8 45 9 0 18 4 50 10 0 20 0 HYGRASGARD KFTF 20 VA Duct humidity and temperature sensors 1 8 ID Typ Messbereich Anzeige Feuchte Temperatur Ausgang Display Feuchte Temper...

Страница 10: ...B GND optional for LCD backlighting 3 wire connection for devices with without display not illuminated 4 wire connection for devices with illuminated display At the I variant the humidity path must necessarily be connected Temperature measuring ranges adjustable DIP 1 DIP 2 35 75 C O N O N 35 35 C OFF OFF 0 50 C default OFF O N 0 80 C O N OFF Pin assignment M12 Pin assignment M12 KFTF 20 U KAFTF 2...

Страница 11: ...ge reverse polarity protection a one way rectifier or reverse polarity protection diode is integrated in this device variant This internal one way rectifier also allows operating 0 10 V devices on AC supply voltage The output signal is to be tapped by a measuring instrument Output volt age is measured against zero potential O V of the input voltage When this device is operated on DC supply voltage...

Страница 12: ...ded and EMC directives are to be observed This device shall only be used for its intended purpose Respective safety regulations issued by the VDE the states their control authorities the TÜV and the local energy supply company must be observed The purchaser has to adhere to the building and safety regulations and has to prevent perils of any kind No warranties or liabilities will be assumed for de...

Страница 13: ...dité 0 100 h r sortie correspond à 0 10 V ou 4 20 mA Humidité d air admissible 95 h r air sans condensation Écart humidité typique 1 8 10 90 h r à 25 C sinon 2 0 Sortie humidité 0 10 V pour variante U 4 20 mA pour variante TEMPÉRATURE Plage de mesure température commutation multi gamme voir tableau 35 35 C 35 75 C 0 50 C 0 80 C sortie correspond à 0 10 V ou 4 20 mA Température ambiante stockage 35...

Страница 14: ...0 5 5 7 13 1 10 6 4 14 3 15 7 1 15 4 20 7 9 16 6 25 8 6 17 7 30 9 3 18 9 35 10 0 20 0 Tableau de température plage de mesure 0 50 C C UA V IA mA 0 0 0 4 0 5 1 0 5 6 10 2 0 7 2 15 3 0 8 8 20 4 0 10 4 25 5 0 12 0 30 6 0 13 6 35 7 0 15 2 40 8 0 16 8 45 9 0 18 4 50 10 0 20 0 HYGRASGARD KFTF 20 VA Sonde d humidité et de température pour montage en gaine 1 8 ID Type plage de mesure affichage humidité te...

Страница 15: ...r LCD backlighting Raccordement 3 fils pour appareils sans avec écran non éclairé Raccordement 4 fils pour appareils avec écran rétro éclairé Pour la variante I il faut impérativement raccorder la sortie humidité Temperatur Messbereiche einstellbar DIP 1 DIP 2 35 75 C O N O N 35 35 C OFF OFF 0 50 C default OFF O N 0 80 C O N OFF Affectation des plots de connexion M12 Affectation des plots de conne...

Страница 16: ...sion de polarité c à d elle comprend un redressement demi onde diode de re dressement Grâce à cette diode de redressement intégrée les appareils 0 10 V peuvent également être alimentés en courant alternatif Le signal de sortie doit être prélevé avec un appareil de mesure Ce faisant la tension de sortie est mesurée par rapport au potentiel zéro O V de la tension d entrée Si cet appareil est aliment...

Страница 17: ...èle avec des câbles de puissance les directives CEM sont à respecter Cet appareil ne doit être utilisé que pour l usage qui est indiqué en respectant les règles de sécurité correspondantes de la VDE des Länders de leurs organes de surveillance du TÜV et des entreprises d approvisionnement en énergie locales L acheteur doit respecter les dispositions relatives à la construction et à la sécurité et ...

Страница 18: ... 10 B или 4 20 мА Допустимая влажность воздуха 95 отн вл без конденсата Погрешность влажность обычно 1 8 10 90 отн вл при 25 C иначе 2 0 Выходной сигнал влажности 0 10 B для варианта U 4 20 мА для варианта I ТЕМПЕРАТУРА Диапазон измерения температуры переключение между несколькими диапазонами см таблицу 35 35 C 35 75 C 0 50 C 0 80 C на выходе соответствует 0 10 B или 4 20 мА Температура окружающей...

Страница 19: ...0 9 0 5 0 12 0 5 5 7 13 1 10 6 4 14 3 15 7 1 15 4 20 7 9 16 6 25 8 6 17 7 30 9 3 18 9 35 10 0 20 0 Таблица значений температуры Диап темп 0 50 C C UA B IA мA 0 0 0 4 0 5 1 0 5 6 10 2 0 7 2 15 3 0 8 8 20 4 0 10 4 25 5 0 12 0 30 6 0 13 6 35 7 0 15 2 40 8 0 16 8 45 9 0 18 4 50 10 0 20 0 HYGRASGARD KFTF 20 VA Датчик влажности и температуры канальный 1 8 ID Тип Диапазон изм индикация влажность температ...

Страница 20: ...ty 4 20mA in r H Output temperature 4 20mA in C UB GND optional for LCD backlighting 1 2 3 4 5 45 1 2 3 4 5 UB 24V AC DC Output humidity 0 10V r H Output temperature 0 10V C UB GND Shield 1 2 3 4 5 45 1 2 3 4 5 UB 24V DC Output humidity 4 20mA r H Output temperature 4 20mA C UB GND optional for LCD backlighting Shield 3 проводное подключение для устройств без дисплея с дисплеем без подсветки 4 про...

Страница 21: ...я в данный вариант прибора интегрирован однополупериодный выпрямитель или диод защиты от напряжения обратной полярности В случае приборов рассчитанных на напряжение 0 10 В этот встроенный выпрямитель до пускает также эксплуатацию при питании напряжением переменного тока Выходной сигнал следует снимать измерительным прибором Выходное напряжение при этом измеряется относительно нулевого потенциала 0...

Страница 22: ... линий и учитывать предписания по электромагнитной совместимости Данный прибор следует применять только по прямому назначению учитывая при этом соответствующие предписания VDE союза немецких электротехников требования действующие в Вашей стране инструкции органов технического надзора и местных органов энергоснабжения Надлежит придерживаться требований строительных норм и правил а также техники без...

Страница 23: ...spondent à l état de nos connaissances au moment de la publication Elles servent uniquement à informer sur nos produits et leurs possibilités d application mais n offrent aucune garantie pour certaines caractéristiques du produit Etant donné que les appareils sont soumis à des conditions et des sollicitations diverses qui sont hors de notre contrôle leur adéquation spécifique doit être vérifiée pa...

Страница 24: ...24 HYGRASGARD KFTF 20 VA ID D G F r KFTF 20 VA LCD KFTF 20 VA KFTF 20 VAQ LCD KFTF 20 VAQ Montageschema KFTF xx Mounting diagram Schéma de montage Схема монтажа ...

Отзывы: