22
MANUFACTURER’S PLACEMENT INSTRUCTIONS
PROPER ASSEMBLY, INSTALLATION, USE, AND SUPERVISION ARE ESSENTIAL FOR PROPER
OPERATION AND TO REDUCE THE RISK OF SERIOUS INJURY.
1. The critical dimensions for placement of the TurboTwister are as shown in Figure W and Figure X.
A. The slide exit runway surface shall not exceed 20” above the water surface as shown in Figure
W.
B. The slide shall be positioned so that all water flowing off the runway exit drops into the pool. The
recommended overhang is 4”.
C. The minimum depth of water below the exit lip of the slide shall be 3’-0” and increase to 4’-6” at
Point A, which is a distance of 4’-6” from the exit lip of the slide as shown in Figure W.
D. A minimum depth of 4’-6” shall be maintained at a distance of 9’-0” along the extended centerline
of the slide from Point A, as shown in Figure W.
2. A minimum clearance area in front of the slide exit shall be
maintained at all times as follows:
A. The minimum clearance distance on either side of the extended
centerline of the slide runway shall not be less than 3’-6” at a
point no less than 2’-6” from the exit lip of the slide and
extending a distance of 13’-6” in front of the slide as shown in
Figure X.
Figure X
Figure W