background image

www.srsmith.com

79-15152-00 Rev E2  9.14 

Page 2 of 10

 

 

 

SAVE THESE INSTRUCTIONS!

 

 

These directions are provided to ensure the proper installation and operation of S.R. Smith Color Light 
Streams™ Large Laminar.  The maximum lighted distance of the laminar stream should be 
considered 6ft height and 6ft in distance.  If the laminar arc is over 6ft there is a high degree of 
probability that the lighting will not travel the full distance to the bottom of the laminar flow.  Also, if the 
throw distance is over 6ft, the lighting will also fail to go the full distance of the laminar stream. 

 

 

 

IMPORTANT GENERAL SPECIFICATIONS:

 

 

1. 

The water supply to the Color Light Streams Laminar fountains 

must 

be filtered with a 

cartridge filter. 

Sand filter and DE filters will likely produce small particles of debris that will 

clog the filter screens internal to the laminar flow fountains. 

 

2.  Water supply is dependent upon 3 important factors: 

a.  Pump size – if dedicated pump is used it must be a minimum of a ½ hp and supply 

proper flow rate at 16 ft of head. 

b.  Plumbing pipe size 
c.  Number of laminar flow fountains on system 

 

 

 

 

 

3.  Each S.R. Smith Color Light Streams Large Laminar flow fountain requires 12VAC. 

Minimum 

sized conduit is 3/4”

.  Run the supplied 100ft of 12VAC wire from the Color Light Stream LED 

driver through the conduit back to the location of your transformer (not included). 

 

4.  S.R. Smith Color Light Streams Large Laminar flow fountains can be placed in most any 

location from concrete decks, raised bond beams or even softscapes.  Be sure that the 
distance from the interior pool wall to the laminar flow fountain is no further than 5’.  This would 
allow the lighted laminar flow stream to be 1’ into the pool interior. 

IMPORTANT:

 

Read and follow all safety and installation instructions carefully before 
installation.

 

The product must be installed in accordance with the applicable installation code by a 
person familiar with the construction and operation of the product and hazard 
involved. 

NOTE: GENERAL RULE OF THUMB IS THAT EACH LAMINAR FOUNTAIN REQUIRES 

APPROXIMATELY 10 GPM.

 

SEE FOLLOWING SECTION ON DESIGN CRITERIA

 

THE LAMINAR FLOW DECK BOX IS MADE OF ABS MATERIAL.  USE ONLY ABS-PVC GLUE 

WHEN MAKING ANY CONDUIT CONNECTIONS TO THIS DECK BOX

 

Содержание Color Light Streams Large Laminar

Страница 1: ...com 79 15152 00 Rev E2 9 14 Page 1 of 10 Color Light Streams Large Laminar Installation Manual CLSLL Input Power 12V AC Total Power 5W 4008814 ETL listed for installations within 5 ft 1 5M of outer ed...

Страница 2: ...at 16 ft of head b Plumbing pipe size c Number of laminar flow fountains on system 3 Each S R Smith Color Light Streams Large Laminar flow fountain requires 12VAC Minimum sized conduit is 3 4 Run the...

Страница 3: ...lanter areas Laminar lid should be 2 inches ABOVE the landscape area to prevent materials from intruding or washing into the fountain itself 3 Remove the laminar flow fountain from the deck box assemb...

Страница 4: ...hat the Color Light Streams Large Laminar flow fountains remain level Utilizing the Adjustable Deck Flange adjust to match your deck height 12 After the deck box has been installed and system has been...

Страница 5: ...e outlet orifice must be avoided MAXIMUM HEIGHT AND DISTANCE IS 6 UP 6 OUT DO NOT EXCEED 15 GPM PER LAMINAR OR DAMAGE CAN BE DONE INTERNALLY of Large Laminars 1 2 3 4 C C C C Plumbing Chart B Plumbing...

Страница 6: ...color mode is selected the modes will cycle 1 2 3 4 5 6 7 8 then cycle back to 1 and repeat see table at bottom of this page Color Sync Reset The memory function may make it difficult get all lights...

Страница 7: ...aminar flow fountains are susceptible to wind conditions and the higher the angle of your fountain the more they may be effected If your area has regular amounts of high winds you may consider moving...

Страница 8: ...4 Gently pry one of the mounting arms away from the jet body and roll the jet body out of the mounting arms the second arm should release easily once the first one is clear Take care to not damage or...

Страница 9: ...www srsmith com 79 15152 00 Rev E2 9 14 Page 9 of 10...

Страница 10: ...side of the lid parallel with the slot in the lid so that the lid is supported yet raised up from the deck box base 6 Turn back on the system and reestablish water flow to the fountain 7 The scratcher...

Отзывы: