REFER TO THE DIAGRAM ON THE FRONT OF THIS MANUAL FOR THE FOLLOWING 
PROCEDURES 
1)  SEE OUR GENERAL INSTALLATION MANUAL FOR FIBER AND CONDUIT INSTALLATION 

IN THE POOL.  THIS MANUAL COVERS THE 6000 SERIES ILLUMINATOR INSTALLATION 
ONLY. 

2) CUT THE FIBER CONDUITS SO THEY WILL ENTER THE INSTALLATION BASE 

APPROXIMATELY HALFWAY.  CUT THE ELECTRICAL CONDUIT SO IT WILL PROTRUDE 
PAST THE CONDUIT HOLE 1” OR LESS (FIG A.).  PULL ALL FIBER OPTIC CABLES AT 
LEAST 12” THROUGH THE TOP OF THE INSTALLATION BASE. 

3)  FOLLOW THE PORT ASSEMBLY PROCEDURES ON THE BACK OF THIS MANUAL. 
4)  PLACE THE CHASSIS ON THE INSTALLATION BASE.  SECURE THE ILLUMINATOR WITH 

THE TWO SCREWS SUPPLIED.  SNAP THE PORT INTO THE CLIP ON THE CHASSIS.  MAKE 
MAKE SURE IT SEATS FIRMLY INTO THE CLIP (FIG B.). 

5)  MAKE THE ELECTRIC CONNECTIONS AS SHOWN ON THE PREVIOUS PAGE.  MAKE SURE 

NO WIRES INTERFERE WITH THE COOLING FAN OR COLOR WHEEL. 

6)  a)  IF INSTALLING IN THE GROUND: 

BACKFILL HALFWAY UP THE INSTALLATION BASE.  ALLOW AMPLE HEIGHT FOR TOP 
SOIL AND LANDSCAPING.  DO NOT ALLOW THE VENTS ON THE BOTTOM OF THE 
ILLUMINATOR TO BE BLOCKED.  THIS WILL CAUSE THE ILLUMINATOR TO OVERHEAT 
AND SHUT OFF. 
b)  IF SURFACE MOUNTING: 
USE PROPER SECURING SCREWS FOR THE SURFACE TYPE YOU ARE ATTACHING TO, 
USING THE 2 HOLES PROVIDED ON THE BASE.  EXAMPLE: FOR CONCRETE, USE 
PROPER CONCRETE SCREWS.  FOR WOOD SURFACE, USE PROPER WOOD SCREWS. 

FIG A. 

APPROVED CONDUITS FOR USE WITH FIBER 
OPTIC CABLES 

  White PVC conduit/pipe SCH 40 or SCH 80 

  Gray PVC conduit/pipe SCH 40 or SCH 80 

  Flexible PVC pipe 

  Black poly pipe 

  Any other suitable conduit 

FIBER CONDUIT HOLE 

AT LEAST 12” OF FIBER 
MUST BE PROTRUDING PAST HOLE 

ELECTRICAL CONDUIT HOLE 

ELECTRIC CONDUIT SHOULD 
PROTRUDE 1” OR LESS 

USE SWEEP ELLS OR HEAT BEND 
FOR GENTLE RADIUS 

FIG B. 