79-15022-00 REV. E2
www.srsmith.com
Page 3 of 4
REFER TO THE DIAGRAM ON THE FRONT OF THIS MANUAL FOR THE FOLLOWING
PROCEDURES
1) SEE OUR GENERAL INSTALLATION MANUAL FOR FIBER AND CONDUIT INSTALLATION
IN THE POOL. THIS MANUAL COVERS THE 6000 SERIES ILLUMINATOR INSTALLATION
ONLY.
2) CUT THE FIBER CONDUITS SO THEY WILL ENTER THE INSTALLATION BASE
APPROXIMATELY HALFWAY. CUT THE ELECTRICAL CONDUIT SO IT WILL PROTRUDE
PAST THE CONDUIT HOLE 1” OR LESS (FIG A.). PULL ALL FIBER OPTIC CABLES AT
LEAST 12” THROUGH THE TOP OF THE INSTALLATION BASE.
3) FOLLOW THE PORT ASSEMBLY PROCEDURES ON THE BACK OF THIS MANUAL.
4) PLACE THE CHASSIS ON THE INSTALLATION BASE. SECURE THE ILLUMINATOR WITH
THE TWO SCREWS SUPPLIED. SNAP THE PORT INTO THE CLIP ON THE CHASSIS. MAKE
MAKE SURE IT SEATS FIRMLY INTO THE CLIP (FIG B.).
5) MAKE THE ELECTRIC CONNECTIONS AS SHOWN ON THE PREVIOUS PAGE. MAKE SURE
NO WIRES INTERFERE WITH THE COOLING FAN OR COLOR WHEEL.
6) a) IF INSTALLING IN THE GROUND:
BACKFILL HALFWAY UP THE INSTALLATION BASE. ALLOW AMPLE HEIGHT FOR TOP
SOIL AND LANDSCAPING. DO NOT ALLOW THE VENTS ON THE BOTTOM OF THE
ILLUMINATOR TO BE BLOCKED. THIS WILL CAUSE THE ILLUMINATOR TO OVERHEAT
AND SHUT OFF.
b) IF SURFACE MOUNTING:
USE PROPER SECURING SCREWS FOR THE SURFACE TYPE YOU ARE ATTACHING TO,
USING THE 2 HOLES PROVIDED ON THE BASE. EXAMPLE: FOR CONCRETE, USE
PROPER CONCRETE SCREWS. FOR WOOD SURFACE, USE PROPER WOOD SCREWS.
FIG A.
APPROVED CONDUITS FOR USE WITH FIBER
OPTIC CABLES
•
White PVC conduit/pipe SCH 40 or SCH 80
•
Gray PVC conduit/pipe SCH 40 or SCH 80
•
Flexible PVC pipe
•
Black poly pipe
•
Any other suitable conduit
FIBER CONDUIT HOLE
AT LEAST 12” OF FIBER
MUST BE PROTRUDING PAST HOLE
ELECTRICAL CONDUIT HOLE
ELECTRIC CONDUIT SHOULD
PROTRUDE 1” OR LESS
USE SWEEP ELLS OR HEAT BEND
FOR GENTLE RADIUS
FIG B.
INSTALLATION GUIDELINES