S.P.E. CBHF1-SM Скачать руководство пользователя страница 4

OPERATING MANUAL 

GENERAL

 

INFORMATION

 

AND

 

WARNINGS 

 

Electronic automatic battery charger with microprocessor suitable for any battery type.  

 

Fully automatic charging cycle with electronic setting; protected against overload, short-circuit at clamps 
and reversed polarity. 

 

Never disconnect the battery while charging: this could cause sparks. 

 

Never use the equipment in the rain, in areas used for washing or in damp areas. 

 

Before starting to charge, make sure the voltage of the equipment suits the voltage of the battery, that the charging 
current  suits  the  capacity  of  the  battery  and  that  the  selected  charging  curve  (for  lead-acid  batteries  or  airtight  gel 
batteries) is correct for the type of battery to be charged. In addition, make sure the rated input voltage of the charger 
suits the available supply voltage and the system is equipped with grounding. 

 

If necessary, replace the fuse with another of the same type and value as indicated on the rating plate. 

 

Use battery chargers only in well ventilated areas. 

 

Pay attention to any remarks of the battery manufacturer. 

For lead-acid batteries with liquid electrolyte: 

 

Control the water level after each charging process. 

 

Refill with distilled water only. 

 

Caution!  The  gases  generated  during  charging  are  explosive.  Do  not  smoke  in  the  vicinity  of  the 
batteries. When working with cables and electrical equipment, avoid open flames and sparks. 

 

Attention: Use protective glasses and gloves during battery maintenance. Battery acid causes injuries. In 
case of contact with battery acid, wash the affected parts with a lot of fresh water and consult a doctor if 
necessary. 

 

CONTROLS (see figure behind the cover) 

1.  Three-digit  display  +  symbol  (1),  to  view  A  =  the  charging  current,  U  =  the  battery  voltage,  h  =  the 

charging time, C = the charging ampere-hours [Ah], E = the energy used [KWh]. 

2.  Button for the 

S

election of the display mode (2): A, U, h, C, E. After about 10 seconds the display returns 

to the visualization of the charging current. 

3.  Red control indicator (3): when it is on, the charging cycle has started. 
4.  Yellow control indicator (4): when it is on, the final phase of the charging cycle has started. 
5.  Green control indicator (5): when it is on, the charging cycle has finished. 

 

OPERATION 

 

Plug the cord into a socket. 

 

Connect the battery, checking the polarity. 

 

Now, the battery charger’s display will show a sequence of details on the charger’s internal programming: 
after the name “SPE”, it will show the software release installed in the equipment, then, in sequence, the 
following  parameters:  battery  voltage,  charging  current,  charging  curve  number  and,  finally,  the  words 

“GEL” 

or “

Acd

”  depending on the set up charging curve being suitable for airtight gel batteries or lead-

acid batteries. 

Make sure the type of batteries to be charged (gel or lead-acid batteries) matches the 

displayed details (“GEL” or “Acd”, respectively). If it doesn’t, contact our dealer.

 Now, a test is run 

on  the  battery  voltage  to  decide  if  the  charging  process  should  be  started  or  not.  If  the  battery  is  not 
connected to the battery charger, the display will show the word 

“bat”

. The word will stay on, even if the 

test  is  failed  (for  instance,  reversed  polarities  or  incorrect  battery  connection).  If  the  test  is  passed,  the 
display will show the battery voltage for approximately 5 seconds and the battery will begin to be charged. 
The charging cycle progress will be shown by red (3), yellow (4) and green (5) LED indicators.  
At  the  end  of  the  charge,  when  the  green  indicator  (5)  is  on,  unplug  ther  cord  from  the  socket  and 
operate the machine. 

 

PROBLEMS 

SOLUTIONS AND CHECKS 

The battery charger does not switch on 

Check that the plug is connected to the supply mains and that 
the fuse is efficient. 
 

The  charging  cycle  does  not  start  and  the  message 

bat

’ is displayed 

Check the connection to the battery and the polarity. 

The  yellow indicator  (4)  will  not  light  up  even  15  hours 
from  the  starting  of the charging  cycle,  and  the  display 
shows 

E03

Check the battery for possible faulty components. 

The message 

E01 

is displayed 

This  means  that  the  maximum  voltage  admissible  by  the 
battery has been exceeded. The charging is interrupted. 

If  the  battery  charger  is  provided  with  a    safety 
thermostat and the message 

E02

 is displayed.  

This  means  that  the  maximum  temperature  has  been 
exceeded. The charging is interrupted. 

The message 

E03 

is displayed 

This means that the maximum time for the charging phase has 
been exceeded. The charging is interrupted. 

The message 

SCt 

is displayed 

This  means  that  the  total  safety  timer  has  interrupted  the 
charging. 

The message

 Srt 

is displayed 

This signals a possible internal short circuit. 

 
 
 
 