- Stop the flow of water to the tap.
- Disconnect the 3/8” male union of the
delivery hose. Connect it to the female fitting
supplied. Connect the 8 mm plastic tube to the fitting.
- Connect the 3/8” female fitting of the delivery
hose to the male fitting supplied.
- Connect the IN and OUT of MIOLED respecting the inlet and outlet described by the arrows on the label (below
example with a flexible 3/8 "female tap):
-
Open the inlet water supply and check that there are no water leaks in any part of the system.
-
Connect MIOLED to the electricity.
-
Check that the sterilized water comes out and the LED is on the STATUS LED window (the LED lights up
only when water flows).
-
Let the disinfected water flow out for at least 10 minutes before using it, in order to purge any impurities,
present in the system.
NOTE: It is recommended to install a water filter directly before the UV sterilizer in order to remove any suspended
particles present in the water to be treated, which could limit the disinfection effectiveness.