![S.E.F.A SUBLIMAX 1812 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/s-e-f-a/sublimax-1812/sublimax-1812_instruction-manual_3100070024.webp)
V0116
Page 24
IX.
MAINTENANCE
USE
BY
QUALIFIED
STAFF
ONLY
ANY SERVICING INTERVENTION MUST BE DONE WHEN THE MACHINE IS OFF AND LOCKED
(ELECTRIC AND PNEUMATIC ENERGIES UNPLUGGED)
1.
SERVICING
Heat transfer press SEFA ® require little maintenance. To ensure proper operation, follow the
preventive guidelines listed below.
Do not heat objects that could damage or even cut the silicon rubber or damaging the Teflon surface
DAILY :
Check the air intake on the right side, the purge filter if there is too
much condensation
.
MONTHLY :
Check and lubricate the axes if necessary
.
ACCORDING TO THE USE :
Change felt every 6 months
.
2.
PARTS SUBJECTED TO WEAR AND TEAR
For all orders
: specify the reference, description and the quantity you want.
Reference
Description
Quantity
FEU-006
NOMEX FELT Ep. 9mm width 2M 1600gr/M²
sold by ML
FEU-030
NOMEX FELT Ep. 6mm width 2M 4000gr/M²
sold by ML
TOI-001
NOMEX FABRIC 230gr/M² width 1,65M (ecru color)
sold by ML
SON-PT100
PT100 CONTACT PROBE special Sublimax (fixing eyelet)
1