INSPECTIONS
We at S.E.A. Paragliders recommend to do a technical inspection of the harness every 24 months.
The full inspection can be done by the manufacturer or his representative.
It is highly recommended with regular pre-flight checks to do inspection thoroughly on every rescue repack of 6
months. Additional inspections should be performed after any accident, bad landing or take off, or if there are any
signs of damage, tearing or some wear. Always ask professional advice if you are in doubt.
The following checks should be done:
- After a long period of storage, you shoul to do visual inspection the main parts and units of harness.
- Check all webbings, straps and buckles for wear and damage, especially in the “hidden” areas, such as the inside
of the carabiner hook-in points.
- All sewing and stitches must be intact.
- Special attention should be paid to the rescue installation, mounting of rescue handle with its pins.
- Check the integrity and impermeability of the protector.
- The main carabiners must be replaced at least every 5 years or after 500 hours, whatever comes first. Impacts may
create undetectable cracks that could result in structural failure under continuous load.
At the end of service life the harness must be disposed properly. Please, send it back to manufacturer for correct
disposal.
DISPOSAL, RECYCLING