Ryobi RY46501B Скачать руководство пользователя страница 7

7

EXTENSION CORDS

When using a power tool at a considerable distance from 
a power source, be sure to use an extension cord that has 
the  capacity  to  handle  the  current  the  tool  will  draw.  An  
undersized cord will cause a drop in line voltage, resulting in 
overheating and loss of power. Use the chart to determine 
the minimum wire size required in an extension cord. Only 
round jacketed cords listed by Underwriter’s Laboratories 
(UL) should be used.
When working outdoors with a tool, use an extension cord 
that is designed for outside use. This type of cord is desig-
nated with “WA” on the cord’s jacket.
Before  using  any  extension  cord,  inspect  it  for  loose  or  
exposed wires and cut or worn insulation.

**Ampere rating  (on tool data plate)

 

 

0-2.0 

2.1-3.4 

3.5-5.0  5.1-7.0  7.1-12.0   12.1-16.0

Cord Length   

 Wire Size (A.W.G.)

  25´ 

16 

16 

16 

16 

14 

14

  50´ 

16 

16 

16 

14 

14 

12

  100´ 

16 

16 

14 

12 

10 

**Used on 12 gauge - 20 amp circuit.
NOTE: AWG = American Wire Gauge

WARNING:

Keep  the  extension  cord  clear  of  the  working  area. 
Position the cord so that it will not get caught on lumber, 
tools, or other obstructions while you are working with 
a power tool. Failure to do so can result in serious per-
sonal injury.

WARNING:

Check  extension  cords  before  each  use.  If  damaged 
replace immediately. Never use tool with a damaged cord 
since touching the damaged area could cause electrical 
shock resulting in serious injury.

ELECTRICAL

DOUBLE INSULATION

Double insulation is a concept in safety in electric power 
tools,  which  eliminates  the  need  for  the  usual  three-
wire  grounded  power  cord.  All  exposed  metal  parts  are  
isolated  from  the  internal  metal  motor  components  with 
protecting  insulation.  Double  insulated  tools  do  not  need 
to be grounded.

WARNING:

The  double  insulated  system  is  intended  to  protect 
the user from shock resulting from a break in the tool’s 
internal insulation. Observe all normal safety precautions 
to avoid electrical shock.

NOTE: Servicing of a tool with double insulation requires 
extreme care and knowledge of the system and should be 
performed only by a qualified service technician. For service, 
we suggest you return the tool to your nearest authorized 
service center for repair. Always use original factory replace-
ment parts when servicing.

ELECTRICAL CONNECTION

This tool has a precision-built electric motor. It should be 
connected to a 

power supply that is 120 volts, 60 Hz, AC 

only (normal household current). Do not operate this tool 
on direct current (DC). A substantial voltage drop will cause 
a loss of power and the motor will overheat. If your tool does 
not operate when plugged into an outlet, double-check the 
power supply.

GFCI

Ground  Fault  Circuit  Interrupter  (GFCI)  protection  should 
be provided on the circuit(s) or outlet(s) to be used for the 
cultivator.  Receptacles  are  available  having  built-in  GFCI 
protection and may be used for this measure of safety.

Содержание RY46501B

Страница 1: ...red and manufactured to our high standard for dependability ease of operation and operator safety When properly cared for it will give you years of rugged trouble free performance WARNING To reduce th...

Страница 2: ...nd dependability have been given top priority in the design of this product making it easy to maintain and operate Introduction 2 General Safety Rules 3 Specific Safety Rules 4 Symbols 5 6 Electrical...

Страница 3: ...lds Everyday glasses have only impact resistant lenses They are NOT safety glasses Following this rule will reduce the risk of eye injury Use face mask if operation is dusty GENERAL SAFETY RULES Wear...

Страница 4: ...operate the equipment on a slope Use extreme caution when pulling the machine towards you When not in use cultivator should be stored indoors in a dry locked up place out of the reach of children Mai...

Страница 5: ...DESIGNATION EXPLANATION Voltage Current Frequency cycles per second Power Time Type of current Type or a characteristic of current Rotational speed at no load Double insulated construction Revolutions...

Страница 6: ...rdous situation which if not avoided may result in minor or moderate injury CAUTION Without Safety Alert Symbol Indicates a situation that may result in property damage WARNING To avoid serious person...

Страница 7: ...ld cause electrical shock resulting in serious injury ELECTRICAL DOUBLE INSULATION Double insulation is a concept in safety in electric power tools which eliminates the need for the usual three wire g...

Страница 8: ...elf with all operating features and safety rules JUST ADD SAND Putting sand in the sand tank allows greater stability when operating the cultivator and also gives added weight to the machine allowing...

Страница 9: ...make sure no breakage or damage occurred during shipping Do not discard the packing material until you have care fully inspected and satisfactorily operated the tool If any parts are damaged or missi...

Страница 10: ...its wheels so that the handlebar rests on the ground Place tine C on the tine shaft to the left of the gear box The stamped side of the tine should face away from the gear box Place tine B on the tine...

Страница 11: ...continue to rotate until the switch trigger is released Failure to avoid contact could cause serious personal injury ASSEMBLY ADDING SAND See Figure 6 The cultivator is equipped with a Just Add Sand w...

Страница 12: ...an ahead to leave enough room between the seed rows to allow for machine cultivating after the plants have grown With the wheel assembly accessory installed in position A as described on page 14 roll...

Страница 13: ...nit to allow a more narrow cultivating width To remove the two outer tines Unplug the cultivator Remove the hitch pins from the holes on the ends of the tine shaft Remove the outside tine blades and f...

Страница 14: ...ration of the tine blades into the cultivating surface The wheel assembly accessory may be installed in posi tion B to allow use of the drag bar during cultivating ADJUSTING DRAG BAR POSITION See Figu...

Страница 15: ...t an Authorized Service Center STORING THE CULTIVATOR The following steps should be taken before storing the cul tivator for the season Clean dirt grass and other materials from the entire unit Wipe t...

Страница 16: ...rranty does not extend to repairs made necessary by normal wear or by the use of parts or accessories which are either incompatible with the RYOBI brand outdoor product or adversely affect its operati...

Страница 17: ...17 NOTES...

Страница 18: ...00 860 4050 for your nearest Authorized Service Center You can also check our web site at www ryobitools com for a complete list of Authorized Service Centers MODEL NO AND SERIAL NO The model number o...

Отзывы: