Ryobi RGN1200A Скачать руководство пользователя страница 5

4

English

INTRODUCTION

This product has many features for making its use 

more pleasant and enjoyable. Safety, performance, and 

dependability have been given top priority in the design 

of this product, making it easy to maintain and operate.

 DANGER

 

GROUNDING THE GENERATOR

 (See Figure 1)

 

In Australia and New Zealand, grounding of portable 

generators is not recommended or required.  Consult 

with local electricians to determine grounding 

requirements before operating with a ground 

connection.

IMPORTANT SAFETY INSTRUCTIONS

 

WARNING:

 

Read and understand all instructions.

 Failure 

to follow all instructions listed below may result 

in electrocution, fire, and/or carbon monoxide 

poisoning, which will cause death or serious 

injury.

 

 WARNING:

 

Before using the ground terminal, consult a 

qualified electrician to comply with the intended 

use of the  generator.

SAVE THESE INSTRUCTIONS

This manual contains important instructions that should 

be followed during installation and maintenance of the 

generator and batteries.

n

 

Do not allow children or untrained individuals to use 

this unit.

n

 

Never start or run the engine inside a closed or partially 

enclosed area. Breathing exhaust fumes will kill you.

n

 

Wear eye protection as well as hearing protection when 

operating this equipment.

n

 

Keep all bystanders, children, and pets at least 3m 

away.  

n

 

Wear sturdy and dry shoes or boots. Do not operate 

while barefoot.

n

 

Do not operate the generator when you are tired or 

under the influence of drugs, alcohol, or medication.

n

 

Keep all parts of your body away from any moving parts 

and all hot surfaces of the unit.

n

 

Product users in some states, must comply with fire 

prevention regulations. This product is equipped 

with a spark arrestor in accordance with Australian 

requirements.

n

 

Do not touch bare wire or receptacles.

n

 

Do not use the generator with electrical cords which 

are worn, frayed, bare, or otherwise damaged.

n

 

Before storing, allow the engine to cool.

n

 

Do not operate the generator in rain, snow, or wet 

weather.

n

 

Empty fuel tank, close fuel valve, and restrain the unit 

from moving before transporting in a vehicle.

n

 

Allow engine to cool for five minutes before refueling.

n

 

To reduce the risk of fire and burn injury, handle fuel 

with care. It is highly flammable.

n

 

Do not smoke while handling fuel.

n

 

Store fuel in a container approved for unleaded fuel.

n

 

Position the unit on level ground, stop engine, and allow 

to cool before refueling.

n

 

Loosen fuel cap slowly to release pressure and to keep 

fuel from escaping around the cap.

n

 

Tighten the fuel cap securely after refueling.

n

 

Wipe spilled fuel from the unit.

n

 

Never attempt to burn off spilled fuel under any 

circumstances.

n

 

Use only authorised replacement parts and accessories 

and follow instructions in the Maintenance section of 

this manual. Use of unauthorised parts or failure to 

follow Maintenance instructions may create a risk of 

shock or injury.

n

 

Maintain the unit per maintenance instructions in this 

Operator’s Manual.

n

 

Inspect the unit before each use for loose fasteners, 

fuel leaks, etc. Replace damaged parts.

n

 

The generators vibrate in normal use. During and after 

the use of the generator, inspect the generator as well 

as extension cords and power supply cords connected 

to it for damage resulting from vibration. Have damaged 

items repaired or replaced as necessary. Do not use 

plugs or cords that show signs of damage such as 

broken or cracked insulation or damaged blades.

SPECIFIC SAFETY RULES

 

WARNING:

 

When this generator is used to supply a 

building wiring system:

 the generator must be 

installed by a qualified electrician and connected 

to a transfer switch as a separately derived 

system in accordance with Australian Wiring 

Rules. The generator shall be connected through 

a transfer switch that switches all conductors 

Содержание RGN1200A

Страница 1: ...E GENERATOR SET OPERATOR S MANUAL RGN1200A Important It is essential that you read the instructions in this manual before assembling maintaining and operating this machine Subject to technical modific...

Страница 2: ...Fig 4 Fig 5 Fig 3 OIL CAP DIPSTICK RECOIL STARTER GRIP AIR FILTER CHOKE LEVER FUEL CAP CIRCUIT BREAKER FUEL TANK FUEL CAP OIL CAP DIPSTICK OIL FILL HOLE CARBURETOR DRAIN SCREW OIL CAP DIPSTICK Fig 2 F...

Страница 3: ...2 Fig 6 ON OFF ON OFF Fig 8 Fig 7 AIR FILTER RECOIL STARTER GRIP FUEL VALVE Fig 9 CHOKE LEVER TO START CHOKE CLOSED TO RUN CHOKE OPEN LATCHES CHOKE LEVER TO START CHOKE CLOSED LATCHES...

Страница 4: ...3 21 2 Fig 10 ON OFF Fig 11 Fig 12 Fig 13 ON OFF ON OFF SPARK PLUG CAP SPARK PLUG FUEL LINE FUEL VALVE BARB FUEL VALVE O RING FILTER SEDIMENT CUP OIL DRAINAGE PLUG...

Страница 5: ...or receptacles n Do not use the generator with electrical cords which are worn frayed bare or otherwise damaged n Before storing allow the engine to cool n Do not operate the generator in rain snow or...

Страница 6: ...diately after use they are HOT and will cause burn injury n Do not connect to a building s electrical system unless a transfer switch has been properly installed by a qualified electrician n Do not al...

Страница 7: ...d to observe safe practices can result in electric shock Running the generator gives off carbon monoxide an odourless colourless poison gas Breathing carbon monoxide can cause nausea fainting or death...

Страница 8: ...ormed only by a qualified service technician For service contact your nearest AUTHORISED SERVICE CENTRE for repair When servicing use only identical replacement parts WARNING Observe all normal safety...

Страница 9: ...The unit is equipped with an oil sensor which will automatically shut off the engine if oil level falls below a safe limit HOT SURFACE WARNING Do not touch the muffler or aluminium cylinder of the eng...

Страница 10: ...scribed later in this manual 2 Plug in and turn on the first load preferably the largest load highest wattage you have 3 Permit the generator output to stabilise engine runs smoothly and attached devi...

Страница 11: ...Engine Number UP154 Engine Type 4 Stroke air cooled OHV Gasoline Bore x Stroke mm 54 x 38 Displacement cc 87 Starting System recoil Fuel Type Unleaded fuel Lubrication oil SAE 10W 30 Engine Oil Volum...

Страница 12: ...orhasthefollowingsinglephase 50Hzoutlets one 230 Volt AC 15 Amp receptacle These can be used for operating appropriate appliances electrical lighting tools and motor loads RECOIL STARTER GRIP The reco...

Страница 13: ...l injury APPLICATIONS This generator is designed to supply electrical power for operating compatible electrical lighting appliances tools and motor loads BEFORE OPERATING THE UNIT Position the generat...

Страница 14: ...enerator n Start the engine refer to STARTING THE ENGINE section NOTE Do not start the vehicle while the battery charging cable is connected and the generator is running The vehicle or the generator m...

Страница 15: ...lowing the instructions in the Checking Adding Oil section n Reinstall the oil cap dipstick NOTE Used oil should be disposed of at an approved disposal site See your local oil retailer for more inform...

Страница 16: ...fuel being drained from the tank n Open fuel valve n When the fuel has drained from the tank close the fuel valve and reinstall fuel line on barb DRAINING THE CARBURETOR See Figure 2 n Turn the engine...

Страница 17: ...torage life For recommendations contact your nearest authorised service center MAINTENANCE SCHEDULE Before each use After 1st month or 20 hours of operation Every 3 months or 50 hours of operation Eve...

Страница 18: ...cuit breaker is OFF Item plugged in is defective Turn ON the AC circuit breaker Try a different item Generator makes a spark knock or pinging noise An occasional light knocking or pinging underheavylo...

Страница 19: ...18 English WIRING DIAGRAM RGN1200A...