IMPORTANT SAFETY INSTRUCTIONS

The purpose of safety rules is to attract your

attention to possible dangers. The safety symbols

and the explanations with them, require your

careful attention and understanding. The safety

warnings do not by themselves eliminate any

danger. The instruction or warnings they give are

not substitutes for proper accident prevention

measures.

SAFETY ALERT SYMBOL.

Indicates

caution or warning. May be used in

conjunction with other symbols or

pictures.

Failure to obey a safety warning can result in

serious injury to yourself or to others. Always follow

the safety precautions to reduce the risk of fire,

electric shock and personal injury.
Do not attempt to operate this tool until you have

read thoroughly and completely understood the

safety rules, etc. contained in this manual. Failure

to comply can result in accidents involving fire,

electric shock or serious personal injury. Save this

Owners Operating Manual and review it frequently

for continual safe operation and for instructing

others who may use this tool.

DANGER: CARBON MONOXIDE.

Using a generator indoors CAN KILL

YOU IN MINUTES.

Generator exhaust contains high levels of carbon

monoxide (CO), a poisonous gas you cannot see

or smell. If you can smell the generator exhaust,

you are breathing CO. But even if you cannot smell

the exhaust, you could be breathing CO.
Never use a generator inside homes, garages,

crawlspaces, or other partly enclosed areas.

Deadly levels of carbon monoxide can build up in

these areas. Using a fan or opening windows and

doors does NOT supply enough fresh air.
ONLY use a generator outdoors and far away from

open windows, doors, and vents. These openings

can pull in generator exhaust.
Even when you use a generator correctly, CO may

leak into the home. ALWAYS use a battery

powered or battery-backup CO alarm in the home.
If you start to feel sick, dizzy, or weak after the

generator has been running, move to fresh air

RIGHT AWAY. See a doctor. You could have

carbon monoxide poisoning.

WARNING:

Read and understand all

instructions. Failure to follow all

instructions listed below could result in

electrocution, fire, and/or carbon monoxide

poisoning, which can cause death or serious injury.

WARNING:

In some applications,

National Electric Code requires the

generator to be grounded to an approved

earth ground. Before using the ground terminal,

consult a qualified electrician, electrical inspector,

or local agency having jurisdiction for local codes

or ordinances that apply to the intended use of the

generator.

SAVE THESE INSTRUCTIONS

The generator must be mounted on a firm level

surface.
Do not allow children or untrained individuals to

use this unit.
Keep all bystanders, children, and pets at least 10

feet away.
Wear sturdy and dry shoes or boots. Do not

operate while barefoot.

Do not use E15 or E85 fuel in this product.

It will damage the unit and void your warranty.

Only use unleaded gasoline containing up to

10% ethanol.

Due to continued product

refinement policy, product features

and specifications can and will

change without notice. Check

current features and specifications

with your retailer.

Содержание RG-1250I

Страница 1: ......

Страница 2: ...able service SPECIFICATIONS Engine type forced air single cylinder 4 stroke 53 5cc Engine speed 3800 5200 min Oil tank capacity 250 ml Fuel tank capacity 3 5l Spark plug A7RTC Rated voltage 230V 50Hz...

Страница 3: ...carbon monoxide can build up in these areas Using a fan or opening windows and doors does NOT supply enough fresh air ONLY use a generator outdoors and far away from open windows doors and vents These...

Страница 4: ...or near an explosive atmosphere To prevent an electric shock never operate the machine in rain snow or touch with wet hands Check the fuel system periodically for leaks Seals and hoses should be chec...

Страница 5: ...e and fire tighten fuel filler cap by hand as securely as possible Before use always make sure that the fuel cap has been properly tightened Check for fuel leakage while refuelling and during operatio...

Страница 6: ...ng s electrical system unless a transfer switch has been properly installed by a qualified electrician Do not allow the generator s fuel tank to overflow when filling Fill to 25mm below the top neck o...

Страница 7: ...ap 6 Muffler 7 Air filter connection screws 8 Air filter cover 9 Recoil starter grip 10 Electronic engine switch 11 Control panel 12 Fuel valve 13 Oil pressure alarm indicator 14 Output indicator ligh...

Страница 8: ...side facing up and unscrew the oil filler cap dipstick Fig 1 2 Wipe dipstick clean and re seat in hole do not re thread Remove dipstick again and check the oil level The oil level should fall within t...

Страница 9: ...cing any of the faults that are mentioned above User will need to stop the engine to fix the issue before restarting the engine 5 Safety grounding bolt 6 5V USB socket 4 1 3 2 LOCATION AND GROUNDING B...

Страница 10: ...the carburetor Pull the cord sharply Continue this procedure until the engine starts CAUTION Avoid damaging the plastic case of the crankshaft while pulling the rope Aways return the recoil starter c...

Страница 11: ...to dust dirt moisture or corrosive vapours Do not allow the cooling air slots in the generator to become clogged with foreign material such as leaves snow etc Do not use a garden hose to clean the ge...

Страница 12: ...K PLUG MAINTENANCE The spark plug must be properly gapped and free of deposits in order to ensure proper engine operation To check 1 Remove the spark plug cap Fig 15 2 Clean any dirt from around base...

Страница 13: ...nd or your operating conditions the exhaust port and muffler may become blocked with carbon deposits If you notice a power loss with your petrol powered tool you may need to remove these deposits to r...

Страница 14: ...oved fuel container under the carburetor drain screw to catch fuel loosen the screw Fig 20 Allow fuel to drain completely into container 3 Retighten drain screw 4 After draining the fuel tank and carb...

Страница 15: ...ng Check recoil starter system operation Decarbon More frequently isation if necessary Fittings Check all fittings and fixtures Fastenings and tighten if required SERVICE Now that you have purchased y...

Страница 16: ...s colourless poison gas Breathing carbon monoxide can cause nausea fainting or death Fuel and its vapours are extremely flammable and explosive Fire or explosion can cause severe burns or death To red...

Страница 17: ...n ELECTRIC SYSTEM PROBLEMS Combustion chamber supplied with fuel Poor spark Pull rope sharply Clean tank Clean fuel line with dealers advice Supply fuel Open tap Spark plug dirty with carbon or wet wi...

Страница 18: ...oor connection or faulty lead Broken recepticle Faulty circuit breaker Check and repair Check and repair Generator problem Indicator light OFF No AC output Output power too high or low Engine RPM set...