![Ryobi RA-ACDDU1840 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/ryobi/ra-acddu1840/ra-acddu1840_operators-manual_1503672008.webp)
4
3. Insert a washer at the other end.
4. Secure the rubber foot with a hex nut.
5. Repeat the above steps to install the other foot on the
right.
6. Ensure the compressor is stable by lightly applying
lateral force on it.
iNstALLiNg wHeeLs
See figure 4.
1. Insert an axle bolt and washer in the centre hole of
the wheel.
2. Insert the threaded part of the axle bolt in the hole in
the front supporting frame on the left side. Insert a
washer on both sides of the frame.
3. Secure the axle bolt with a hex nut.
4. Attach the wheel axle cover to the centre of the wheel.
5. Repeat the above steps to install the other wheel on
the right.
6. Ensure the compressor is stable by lightly applying
lateral force on it.
iNstALLiNg Air FiLter
See figure 5.
Attach the air filter to the motor cover. Screw in a clockwise
direction to fasten securely.
OPerAtiON
DANger
Do not disassemble check valve, tank drain valves or
pressure relief valve with air in tank — bleed tank.
wArNiNg
Always wear eye protection with side shields. Failure
to do so could result in objects being thrown into your
eyes resulting in possible serious injury.
wArNiNg
Do not attach any tools to the open end of the hose until
start-up has been completed.
cAUtiON
Do not use in an environment that is dusty or otherwise
contaminated. Using the air compressor in this type of
environment may cause damage to the unit.
trANsPOrtiNg tHe Air cOmPressOr
See figure 6.
The air compressor should be moved as instructed.
This will help you to avoid damaging the wheel or the air
compressor by rolling it over items in its path.
Ensure the air compressor is unplugged, make sure the
power cord is secured in the cord wrap.
to move the air compressor:
1.
Grasp the handle firmly.
2. Tilt the air compressor toward you. Make sure the
compressor is balanced on the wheels.
3. Pull the compressor along to the desired location.
4. Recover the air compressor to its upright position until
it sits securely on a flat surface.
AttAcHiNg/DiscONNectiNg Air HOse
See figure 7.
NOte:
For operation using pressures above 7 bar,
(102 psi) delivery hoses should be fitted with a safety cord,
e.g., wire rope.
1. Make sure the air compressor is off and unplugged.
2. Rotate pressure regulator knob fully counterclockwise.
3.
Confirm that the outlet pressure is at zero (0) bar.
4.
Attach hose with quick connect air fitting to 6.35 mm
(1/4 in.) quick connect coupler (regulated pressure) on
air compressor. Make sure to push the hose adapter
end fully into the coupler until the sleeve springs
forward to lock it in place.
to disconnect an air hose or an air tool:
1. Rotate pressure regulator knob fully counterclockwise.
2.
Confirm that the outlet pressure is at zero (0) bar.
3.
When disconnecting a hose from 6.35 mm (1/4 in.)
quick coupler, always firmly hold release end of hose.
4. Pull back on the release sleeve on the 6.35 mm
(1/4 in.) quick coupler.
5.
With a firm grip, pull out the quick connect air fitting
that is attached to the quick coupler.
tUrNiNg tHe Air cOmPressOr ON/OFF
See figure 9.
1. With the air compressor plugged in, move the power
switch to the AUTO position to power the compressor
on.
2. To turn the air compressor off, move the power switch
to the OFF position.
NOte:
When the compressor is in the AUTO position,
the air compressor will automatically turn on when the
designated tank air pressure drops below the preset
pressure limit. It will also shut off again when the
desired pressure is reached.