14
PRIMER BULB
LEVER
Fig. 15
WARNING:
Never start or run the engine inside a closed or poorly
ventilated area; breathing exhaust fumes can kill.
IGNITION SWITCH
I = ON TO RUN
O = OFF TO STOP
Fig. 14
THROTTLE
TRIGGER
INTERLOCK
TO START A COLD ENGINE:
1. Lay trimmer on a flat, bare surface.
2. Push primer bulb 8 to 10 times.
NOTE: Do not squeeze the throttle trigger before engine
starts. Squeezing the throttle trigger at this time will prevent
the unit from starting.
3. Move the lever to the “COLD START” position.
See
Figure 15.
4. Pull the starter rope until engine runs.
5. Allow the engine to warm up for 4-10 seconds.
6. Depress the interlock, then squeeze and release the
throttle trigger. This allows the choke to automatically
set to the “WARM START” position. Your unit is now
ready for use.
NOTE: The lever will automatically set to the “WARM
START” position after the throttle trigger is squeezed for
the first time.
TO START A WARM ENGINE:
1. Lay trimmer on a flat, bare surface.
2. Choke lever should already be in the “WARM START”
position. If not, squeeze and release throttle trigger.
Pull the starter rope until unit runs.
TO STOP THE ENGINE:
To stop the engine, depress the switch to the “O” position.
STARTING AND STOPPING
See Figures 14 and 15.
NOTE: The unit is equipped with an automatic choke feature.
The starting instructions for this feature are different from units
with a manual choke. Be sure to read and follow the starting
instructions below.
OPERATION
WARM START
POSITION
COLD START
POSITION