background image

3

OPERATION

LED FUNCTION OF CHARGER

See Figure 9. 

LED WILL BE ON TO INDICATE STATUS OF CHARGER

AND BATTERY PACK:

Red LED on = Fast charging mode.

Green LED on = Fully charged battery pack.

No LED on = Defective charge or battery pack.

FEATURES

Figure 1

A. Keyless chuck

B. Switch trigger

C

.

Direction of rotation selector (Forward/Reverse)   

D. Screwdriver bits

E .        Battery pack

F.    Battery LCD indicator

Figure 2

A. Battery pack

B. Latches

C. Depress latches to release battery pack

Note: 

Batteries will not reach full charge the first time

they are charged. Allow several cycles for them to 

fully charge.

TO CHARGE

Charge battery pack only with the charger provided.

Make sure power supply is normal house voltage,

240 volts, 50 Hz, AC only.
Connect charger to power supply.

Place battery pack in charger. Align raised rib on

battery pack with groove in charger.

Press down on battery pack to be sure contacts on

battery pack engage properly with contacts in charger.

When properly connected, red light will turn on.

When your battery pack becomes fully charged, the

red light will turn off and the green light will turn on.

After normal usage, 1 hour of charge time is required

to be fully charged. A minimum charge time of 1 to 

1-1/2 hours is required to recharge a completely

discharged tool.

DO NOT place charger in an area of extreme heat or

cold. It will work best at temperatures above 10

o

C

and below 38

o

C.

IMPORTANT INFORMATION FOR RECHARGING HOT

BATTERIES

When using your tool continuously, the batteries in your

battery pack will become hot. You should let a hot battery

pack cool down for approximately 30 minutes before

attempting to recharge.

CHARGING YOUR BATTERY PACK

The battery pack for your tool has been shipped in a low

charge condition to prevent possible problems.

Therefore, you should charge it prior to use.

Figure 7

A. Unlock (release)

B. Chuck  

C. Drill bit

D. Chuck jaws

E. Lock (tighten)

Figure 8

A. High Speed

B. Low Speed

Figure 9

A. Battery Charger

B. Green Light

C. Red Light

D. Yellow and Green Light

Figure 3 (For CMI1442D/1802D)

A. Auxilary Handle

B. To Tighten

C. To Loosen

Figure 4 (For CMI1442D/1802D)

A. Drill bit

B. Depth Gauge Rod

C. Drilling Depth

Figure 5

A. To Decrease torque

B. To Increase torque

C. Torque adjusting Ring

D. Drill mode

E. Impact mode (For CMI1442D/1802D)

Figure 6

A. Forward / Reverse selector

B. Reverse

C. Forward

D. Switch

Green and Yellow  LED on = Control Charge or Defective

Battery Pack.

Note: Normally the red light on the charger will come 

on, this indicates charge mode.  If the green and yellow 

lights come on, remove the battery pack, wait 1 minute 

and reinsert battery pack in charger.  If the green and 

yellow  lights  continue  to  remain  on  an  additional  15 

minutes,  the  battery  pack  is  damaged  and  will  not 

accept  charge. A  maximum  charge  time  of  1-1  1/2 

hours is required to recharge a completely discharged 

battery.

Figure

 10

 

Battery level indicator

Содержание CMD1802D

Страница 1: ...CMD1802D CMI1442D CMI1802D CORDLESS DRILL DRIVER IMPACT DRILL DRIVER USER S MANUAL ...

Страница 2: ...Fig 1 Fig 3 Fig 2 Fig 5 Fig 4 A C A C D B F E D B A C A B C B C A C E D A B ...

Страница 3: ...Fig 7 Fig 6 Fig 9 Fig 8 A B C D A C D B E B A 85 100 15 85 0 15 0 Fig 10 A C D B ...

Страница 4: ...ice centre unless otherwise indicated in this instruction manual Have defective switches replaced by an authorized service facility Do not use the tool if the switch does not turn it on and off Avoid accidental starting Be sure switch is in the locked or off position before inserting battery pack Carrying tools with your finger on the switch or inserting the battery pack into a tool with the switc...

Страница 5: ...ng off controls will not reduce this risk Disconnect charger from power supply when not in use Risk of electric shock Do not touch uninsulated portion of output connector or uninsulated battery terminal Save these instructions Refer to them frequently and use them to instruct others who may use this unit If you loan someone this unit loan them these instructions also Make sure cord is located so t...

Страница 6: ...will work best at temperatures above 10o C and below 38 o C IMPORTANT INFORMATION FOR RECHARGING HOT BATTERIES When using your tool continuously the batteries in your battery pack will become hot You should let a hot battery pack cool down for approximately 30 minutes before attempting to recharge CHARGING YOUR BATTERY PACK The battery pack for your tool has been shipped in a low charge condition ...

Страница 7: ...the knob clockwise This tool has a variable speed switch that delivers higher speed and torque with increased trigger pressure Speed is controlled by the amount of switch trigger depression ADJUSTING THE DEPTH GAUGE ROB For CMI1442D 1802D See Figure 4 Follow these steps to adjust the depth gauge rod Lock the trigger switch by placing the rotation selector in the center position Loosen the auxiliar...

Страница 8: ...ous condition leading to possible serious personal injury OPERATION WARNING Do not hold the chuck with one hand and use power of the drill to tighten chuck jaws on drill bit Chuck body could slip in your hand or your hand could slip and come in contact with rotating drill bit This could cause an accident resulting in serious personal injury BATTERY INDICATOR The display is for guidance only Deviat...

Страница 9: ...e neglect abuse or used for a purpose for which it was not designed or is not suited and no repairs alterations or modifications have been attempted by other than an Authorised Service Agent This guarantee will not apply if the tool is damaged by accident or if repairs arise from normal wear and tear The Company accepts no additional liability pursuant to this guarantee for the costs of travelling...