manualshive.com logo in svg
background image

11

English

 

„

Clamp the end of the air chuck down onto the presta 

valve adaptor by pressing air chuck clamp down until 

it locks into place.

 

„

After inflation, remove air chuck and tighten locking 

nut.

ACCESSORIES STORAGE
See figure 10.

When not in use, adaptors and needles provided with the 

inflator can be placed in the storage area located on the 

right side of the tool.

HOSE STORAGE
See figures 10 - 11

When not in use, the hoses provided with the inflator can 

be placed in the storage areas located on both sides of 

the inflator.

MAINTENANCE

 WARNING

When servicing, use only identical replacement parts. 

Use of any other parts may create a hazard or cause 

product damage.

 WARNING

Always wear safety goggles or safety glasses with side 

shields during power tool operation or when blowing 

dust. If operation is dusty, also wear a dust mask.

 WARNING

To avoid serious personal injury, always remove the 

battery pack from the tool when cleaning or performing 

any maintenance. 

Avoid using solvents when cleaning plastic parts. Most 

plastics are susceptible to damage from various types of 

commercial solvents and may be damaged by their use. 

Use clean cloths to remove dirt, dust, oil, grease, etc.

 WARNING

Do not at any time let brake fluids, gasoline, petroleum-

based products, penetrating oils, etc., come in contact 

with plastic parts. Chemicals can damage, weaken or 

destroy plastic which may result in serious personal 

injury.

ENVIRONMENTAL PROTECTION

Recycle raw materials instead of disposing 

of as waste. The machine, accessories 

and packaging should be sorted for 

environmental-friendly recycling.

SYMBOLS

Safety alert

Please read the instructions carefully 

before starting the machine.

Risk of injury. Explosive material.

Recycle

Waste electrical products should not be 

disposed of with household waste. Please 

recycle where facilities exist. Check 

with your Local Authority or retailer for 

recycling advice.

Содержание CIT1800G

Страница 1: ...CIT1800G 18 VOLT INFLATOR DEFLATOR OWNER S OPERATING MANUAL ORIGINAL INSTRUCTIONS ...

Страница 2: ...storage 8 Inflator 9 Deflator 10 Pin 11 Battery pack 12 Latches 13 Depress latches to release battery pack 14 Button 15 Mode button 16 Button 17 Valve stem 18 Air chuck 19 To lock 20 To unlock 21 Air chuck clamp 22 Presta valve 23 Presta valve adaptor 24 Locking nut 25 Tapered adaptor 26 Sport ball needle 27 To tighten 28 To loosen 29 Presta valve stem 30 Hose wrap Fig 1 Fig 2 Fig 3 ...

Страница 3: ...2 1 9 17 18 5 19 20 21 22 18 5 19 20 21 23 24 18 25 19 20 23 26 27 28 29 24 Fig 4 Fig 6 Fig 8 Fig 5 Fig 7 Fig 9 ...

Страница 4: ...30 7 30 Fig 10 Fig 11 ...

Страница 5: ...Important It is essential that you read the instructions in this manual before operating this machine Subject to technical modifications ...

Страница 6: ...l injury Use personal protective equipment Always wear eye protection Protective equipment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries Prevent unintentional starting Ensure the switch is in the off position before connecting to power source and or battery pack picking up or carrying the tool Carrying power too...

Страница 7: ... the system slowly Dust and debris may be harmful Never point any inflator toward yourself or others Do not exceed the pressure rating of any component in the system Protect material lines and air lines from damage or puncture Keep hose and power cord away from sharp objects chemical spills oil solvents and wet floors Do not preset inflator to result in output pressure greater than marked maximum ...

Страница 8: ...ot recommended by the manufacturer of this tool The use of attachments or accessories not recommended can result in serious personal injury WARNING Do not leave items to be inflated unattended while inflator is in use These items can burst and could cause serious injury CAUTION The inflator is not designed for continuous use For every ten minutes of inflator use ten minutes of cool down time are r...

Страница 9: ...ssure measurement units from PSI to BAR to kPa Press the mode button to turn on the digital gauge NOTE Make sure digital gauge is set at 0 before use If gauge reads Err or needs resetting press and hold the mode button for 4 7 seconds Select desired measurement unit PSI BAR kPa by pressing and releasing the mode button Press once for PSI twice for BAR and three times for kPa NOTE After preset pres...

Страница 10: ...ESSURE HOSE AND ACCESSORIES See figures 7 9 The high pressure hose can be used with the provided adaptors to inflate a variety of items To install accessory insert adaptor or needle into air chuck and push air chuck clamp down until it locks into place Inflate to desired pressure Remove accessory by lifting air chuck clamp up and pulling the adaptor or needle from air chuck INFLATING MANUALLY FOR ...

Страница 11: ...avoid serious personal injury always remove the battery pack from the tool when cleaning or performing any maintenance Avoid using solvents when cleaning plastic parts Most plastics are susceptible to damage from various types of commercial solvents and may be damaged by their use Use clean cloths to remove dirt dust oil grease etc WARNING Do not at any time let brake fluids gasoline petroleum bas...

Страница 12: ...Techtronic Industries Australia Pty Ltd Level 1 660 Doncaster Road Doncaster VIC 3108 Australia Techtronic Industries New Zealand Ltd 18 26 Amelia Earhart Avenue Mangere Auckland 2022 New Zealand ...

Отзывы: