manualshive.com logo in svg
background image

9

seconds. The tool must not operate.

 

Press the safety yoke firmly against the workpiece, 

and pull the trigger. The tool must operate.

 

With the safety yoke still depressed, release the 

trigger. The driver must return to its up position.

6.  If the tool successfully meets all the requirements 

in this checklist, it is ready for use. Load the proper 

fasteners for the desired application.

7.  Set the depth of drive according to the “drive depth 

adjustment” section in this manual. Repeat this 

checklist before using the tool each day, or if the tool is 

dropped or damaged in any way.

 WARNINg

Do not use any attachments or accessories not 

recommended by the manufacturer of this tool. The use 

of attachments or accessories not recommended can 

result in serious personal injury.

lUBRICAtION

An 

automatic 

in-line 

filter-regulator-lubricator 

is 

recommended (Fig. 11) as it increases product life and keeps 

the product in sustained operation. The in-line lubricator 

should be regularly checked and filled with air tool oil.

Proper adjustment of the in-line lubricator is performed by 

placing a sheet of paper next to the exhaust ports and 

actuate the tool 10 - 15 times without fasteners loaded. 

The lubricator is properly set when a light stain of oil 

collects on the paper. Excessive amounts of oil should be 

avoided.
If it becomes necessary to store the product for an extended 

period of time (overnight, weekend, etc.), it should receive 

a generous amount of lubrication at that time. Actuate the 

tool 10 - 15 times without fasteners loaded to ensure oil 

has been evenly distributed throughout the product. The 

product should be stored in a clean and dry environment. 

 

It is most important that the product be properly 

lubricated by keeping the air line lubricator filled 

and correctly adjusted. Without proper lubrication 

the product will not work properly and parts will 

wear prematurely.

 

Use correct lubricant in the air line lubricator. The 

lubricator should be of low air flow or changing air 

flow type, and should be kept filled to the correct 

level. Use only recommended lubricants, specially 

made for pneumatic applications. Substitutes 

may harm the rubber compounds in the product's 

O-rings and other rubber parts.

IMpORtANt!

See figure 11.

If  a  filter/regulator/lubricator  is  not  installed  on  the  air 

system, air operated tools should be lubricated at least 

once a day or after 2 hours of work with 2 - 6 drops 

of oil, depending on the work environment, directly 

through the male fitting in the tool housing.

20140514v1

Содержание Airwave C1 RA-NB1664-S

Страница 1: ...C Brad Nailer Operator s MANUAL Original instructions RA NB1664 s Important It is essential you read the instructions in this manual before starting and operating this machine Subject to technical mo...

Страница 2: ...4 Fig 6 1 2 2 1 3 1 1 5 8 6 7 7 6 3 2 4 8 Description 1 Nitto style coupler 2 No mar pad 3 Safety yoke 4 Exhaust cap 5 Air supply 6 Nails 7 Pusher 8 Magazine 9 Depth adjustment knob 10 Trigger 11 Jam...

Страница 3: ...1 2 Fig 7 Fig 9 Fig 8 Fig 10 6 7 10 11 12 8 9 Fig 11 Quick connector Quick connector Lubricator Filter Cut off valve Regulator 0 8 5 bar Quick coupler Tool Air compressor Quick coupler Air hose...

Страница 4: ...l the operator should adopt a comfortable posture while maintaining a secure footing and avoiding awkward or off balanced postures The operator should change posture during extended tasks which can he...

Страница 5: ...structions may be used for the maintenance of fastener driving tools Only spare parts specified by the manufacturer or his authorised representative shall be used Repairs shall be carried out only by...

Страница 6: ...al diameter of at least 19 mm and a corresponding large diameter where relatively long pipelines or multiple users are involved Compressed air pipelines should be laid so as to form a gradient highest...

Страница 7: ...force upon the product WARNING Ensure the air supply is clean and does not exceed 8 3 bar 120 psi while operating the product Too high an air pressure and unclean air will shorten the product s life d...

Страница 8: ...a day with heavy use Only a few drops of oil at a time is necessary Too much oil will only collect inside the tool and will be noticeable in the exhaust cycle Before connecting the tool check the air...

Страница 9: ...f each work session before connecting to an air supply 1 Connect the tool to the air supply 2 Slide the pusher all the way to the rear of the magazine 3 With the safety yoke of the tool pointed away f...

Страница 10: ...epth adjustment knob to reach the good fastening effect Work with the lowest possible air pressure This will give you three significant advantages 1 Energy will be saved 2 Less noise will be produced...

Страница 11: ...eezing the moisture in the air line may freeze and prevent tool operation We recommend the use of air tool lubricant or permanent antifreeze ethylene glycol as a cold weather lubricant WARNING Do not...

Страница 12: ...s without fasteners loaded The lubricator is properly set when a light stain of oil collects on the paper Excessive amounts of oil should be avoided If it becomes necessary to store the product for an...

Страница 13: ...damaged O rings or seals Install overhaul kit Tool does nothing or operates sluggishly Inadequate air supply Verify adequate air supply Inadequate lubrication Lubricate tool Worn or damaged O rings or...

Страница 14: ...75 Pin 4 x 16 10 O ring 48 7 x 2 65 32 Guide sleeve 54 Pin bush 76 Trigger 11 O ring 38 x 3 5 33 Bolt M4 x 7 55 Split washer 2 5 77 Safety screen 12 O ring 25 x 3 5 34 Adjusting nut 56 Pin 78 Pin 2 5...

Страница 15: ......

Страница 16: ...Techtronic Industries Australia Pty Ltd Level 1 660 Doncaster Road Doncaster VIC 3108 Australia Techtronic Industries New Zealand Ltd 18 26 Amelia Earhart Avenue Mangere Auckland 2022 New Zealand...