Maintenance Guide
Periodic Maintenance
This melter / applicator requires periodic maintenance before each use and at set intervals in order to ensure it
is performing safely and optimally. The table below describes checks and maintenance which are
recommended.
Description
Before Each
Use
Every 25
Hours
Every 75
Hours
Check Propane Tank fuel level, refill as needed
X
Inspect regulator and hose for physical damage or leaks
X
Inspect front caster wheel, apply grease and tighten fasteners as
required
X
Inspect thermometer for physical damage or malfunctions
X
Remove and thoroughly clean control valve
X
Remove and replace left and right side wheel bushings as
required
X
Procedure for Removing the Flow Valve
1) Remove the cotter pin from the
control arm.
2) Remove the control arm from
the valve and fully rotate the valve
counter-clockwise past the valve
collar.
3) Pull the valve out of the tube.
Содержание RA-MLT-0005
Страница 3: ......
Страница 9: ...3 Handle Bar Assembly KIT F Handle Bar Assembly RK FAS 0001 KIT E Handle Bar Mount RK FAS 0002...
Страница 10: ...4 Agitation Sweep Bar Installation KIT K Agitation Sweep Bar RK FAS 0006...
Страница 12: ...6 On the Fly Agitation Installation KIT J Agitation Bars RK FAS 0005...
Страница 13: ...7 Thermometer and Thermometer Guard Installation 8 Lid Handle Installation KIT D Thermometer Guard RK FAS 0004...
Страница 14: ...9 Shoe Installation KIT I Shoe Mount RK FAS 0027...
Страница 22: ...15 Tank Shelf Installation 16 Propane Tank and Securing Chain Installation Propane Cylinder Not Included...
Страница 24: ...19 Heat Shield Installation KIT G Heat Shield RK FAS 0010...
Страница 25: ...20 Propane Hose Connection Connect the regulator to the propane cylinder and hand tighten...