1.816.353.2100 www.rycominstruments.com
ON/OFF
Button
Turns the unit on and off.
REFERENCE
Button
When pressed it stores the signal strength and sets the reference mode. The tone will beep more
rapidly as the STAFF detects a similar signal strength. Pressing the reference button again (after
a reference has been taken) will display the original reference reading for 2 seconds. Turn the
unit off and on to clear the reference.
DIRECTIONAL ARROW
After proper synchronization the arrows will direct the user to the fault. If the signal strength drops
completely off in the area between the ground rod and the fault, the arrows will not properly
display direction until the unit comes within range of the fault or ground rod.
SIGNAL STRENGTH
The Signal Strength is displayed in a value from 0 to 100. The closer to the ground rod and/or the
fault will result in the highest reading. The signal strength may drop completely off in the area
between the ground rod and the fault.
LOW BATTERY
The
STAFF
Locator
will indicate low battery condition by displaying the Low Battery icon on the
LCD screen.
ON/OFF BUTTON
DIRECTIONAL ARROW
Indicates direction
of fault.
SIGNAL STRENGTH
Displays absolute signal
strength from 0 to 99.
REFERENCE
Stores and displays
starting signal
strength when
pressed
LOW BATTERY INDICATOR
staff r
eCeiver
C
ontrols
and
i
ndiCators
Ground Return Probe (GRP) Fault locating determines the position of an insulated break on an
underground conductor. The Ground Return Probe detects the transmitted signal at the point
(fault) where the signal goes to ground through a break in the insulation.
RYCOM offers two styles of GRPs. One option is the A-Frame accessory that connects to the
receiver via the accessory port, or a stand-alone devices, the STAFF, is capable of operating
without needing to be tethered to the reciver.
grp f
ault
l
oCating
With
a-frame
or
staff