RXAIR RX4500 Скачать руководство пользователя страница 2

RX4500 Manual & Operating Instructions 7/10 

 

www.RXAIR.com

 

 

 2 

Important Safety Instructions 

 

 

READ AND SAVE THESE INSTRUCTIONS

 

 

This Air Purification System includes high voltage electricity and mechanical moving parts. To 
reduce risk of fire, electric shock, or injury to persons, for cleaning and user-maintenance, such 
as filter replacement, the appliance must be disconnected from the power supply prior to 
servicing. 

WARNING: 

To Reduce The Risk Of Electric Shock, Do Not Use This Fan With Any Solid-State 

Speed Control Device.

 

WARNING: DO NOT 

operate in the presence of combustible or explosive gases or powders.

 

CAUTION: 

NEVER operate this equipment without serviceable approved RxAir filters correctly 

installed.   

CAUTION

: ALWAYS lock the unit’s maintenance access doors and remove the keys when the 

unit is in operation to prevent access by unauthorized people.   

 

Additionally for ducted appliance 

 

WARNING 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, 
OBSERVE THE FOLLOWING: 

a.  Installation work and electrical wiring must be done by qualified person(s) in accordance 

with all applicable codes and standards, including fire-rated construction.  

b.  When cutting or drilling into wall or ceiling, do not damage electrical wiring and other 

hidden utilities. 

 

 

 

Содержание RX4500

Страница 1: ...RX4500 Manual Operating Instructions 7 10 www RXAIR com 1...

Страница 2: ...DO NOT operate in the presence of combustible or explosive gases or powders CAUTION NEVER operate this equipment without serviceable approved RxAir filters correctly installed CAUTION ALWAYS lock the...

Страница 3: ...ors 9 4 Installation 10 4 1 Voltage Settings 208 or 230 VAC 11 4 2 Duct Mounting Instructions 12 5 Operation 13 6 Maintenance filter and UV bulb optional 14 6 1 Exterior cleaning 14 6 2 Replacement of...

Страница 4: ...igures page Figure 1 Front View 8 Figure 2 Rear View 8 Figure 3 Controls and Indicators 9 Figure 4 Circuit Compartment 11 Figure 5 Transformer Circuit 11 Figure 6 Duct Installation 12 Figure 7 Open Fi...

Страница 5: ...ised by the user for proper operation of this device or to avoid causing damage to this device or other property A note is provided when general information is applicable 1 2 Warnings Electrical Shock...

Страница 6: ...Warning labels on the device Never place fluids on the top surface of the device Use only RxAir accessories and parts with this device When cleaning the surface of the unit do not use excessive amount...

Страница 7: ...of the room air This is analogous to hand washing s effect on skin contamination and helps to control airborne particulates The effectiveness of the device is dependent upon room parameters such as ro...

Страница 8: ...RX4500 Manual Operating Instructions 7 10 www RXAIR com 8 2 1 Components Figure 1 Front View Figure 2 Rear View...

Страница 9: ...RX4500 Manual Operating Instructions 7 10 www RXAIR com 9 3 Controls and Indicators Figure 3 Controls and Indicators Power Switch Press to turn the unit ON or OFF UV System Indicator optional...

Страница 10: ...e oil is likely to splash In an area that is exposed to direct sunlight In an area where water is likely to splash Near loose materials such as fabrics Outdoors Always place the unit in upright positi...

Страница 11: ...RX4500 Manual Operating Instructions 7 10 www RXAIR com 11 4 1 Voltage Settings 208 or 230 VAC Figure 4 Circuit Compartment Figure 5 Transformer Circuit...

Страница 12: ...the Electrical Supply matches the Transformer Settings 4 2 Duct Mounting Instructions Figure 6 Duct Installation Notes Duct adapter is supplied attached to air purifier by RxAir Contractor to attach f...

Страница 13: ...as to the status of the electrical power outlet please call a qualified electrical contractor The unit may then be turned on by pressing the POWER switch at which time the ON indicator should indicat...

Страница 14: ...for your safety Please refer to the figures on the next page when reading these instructions Step 1 Remove new filters from cartons Step 2 Unlock and open side panel doors one on each side of the RxA...

Страница 15: ...ilter Door Warning Ensure doors are locked after filter installation to prevent unauthorized access Figure 8 Filter Removal Removal and replacement of pre filters Figure 9 Filter Placement Ensure arro...

Страница 16: ...of filter Check and or change pre filter Check filter age may need new filter Contact your representative or RxAir 3 Replace UV bulb indicator optional Check bulb installation Replace bulb Contact yo...

Страница 17: ...XAir com 17 8 Accessories Please contact an authorized RxAir representative or distributor for replacement filter assemblies and other RxAir accessories Call RxAir Customer Service for assistance in l...

Страница 18: ...imum efficiency of 99 97 on 0 3 micron particles Five stage filtration consists of External prefilter Germistatic prefilter RxTrete electrostatic prefilter HEPA Charcoal absorber UV C Germicidal ultra...

Страница 19: ...ove room air then the number of room air changes per hour will be affected RxAir Customer Service for a technical representative if assistance in determining the number of room air changes per hour is...

Страница 20: ...this warranty Any service other than lamp or filter replacement without the written authority of RxAir or its authorized agents voids this warranty A condition of this warranty is that this equipment...

Страница 21: ...anual Operating Instructions 7 10 www RXAir com 21 13 HEPA Module Filter Log Unit Serial Number___________ Manufacturer Part SF4500 Filter Serial Install Date Changed by Filter Serial Install Date Cha...

Страница 22: ...RX4500 Manual Operating Instructions 7 10 www RXAir com 22 14 Pre Filter Log Manufacturer Part SPF4500 Install Date Changed by Install Date Changed by Install Date Changed by...

Отзывы: