RVR Solar Closet 300 PS Скачать руководство пользователя страница 2

2

Closet 300 PS Unit 

Installation, Usage and Maintenance Instructions

Thank you for selecting an RVR Energy Technology product.  This product is the result of extensive research and experi-

ence in water pressurisation.   This manual is an integral part of the product and should be retained.  Please read it careful-

ly, as it provides important information regarding the installation and maintenance of the product.

 

The product should only be installed and maintained by a person qualified in the design and installation of 

water pressurisation systems.   Failure to properly install or maintain the product may lead to injury, death or 

property damage.

01.  INTRODUCTION

This document contains instructions for the use and maintenance of the Closet 300 PS unit.  The Closet 300 PS has been 

designed to pump clean water not containing abrasive particles.

Before installing and using the Closet 300 PS, read the following instructions carefully.  RVR Energy Technology declines 

any responsibility in case of accidents or damage caused by improper use of the unit or due to negligence or lack of ob-

servance of the instructions contained in this booklet or use of the product under conditions outside of the rated specifica

-

tions.

The Closet 300 PS is suitable for the provision of a pressurised water supply in residences and commercial premises. It 

contains the following:

A MULTI-IMPELLER SUBMERSIBLE PUMP which is suitable for use in appli-

cations with up to 40 start/stop cycles per hour.  The pump is fitted with a 

continuous duty asynchronous motor and thermal overload protection.

A PRESSURE CONTROLLER

 which controls the starting and stopping of the 

pump. It must be installed in a vertical position with the water inlet at the 

bottom and the water outlet at the top.  It starts the pump when the outlet 

pressure falls below 1.2 bar and stops when the flow stops. 

A 300 LITRE TANK INCLUDING FLOAT VALVE AND OVERFLOW.  The tank 

is manufactured from WRAS approved material and comes with recessed 

handles for ease of lifting during installation.

PERFORMANCE

Flowrate (l/min)

10

20

30

40

50

60

70

80

Pressure (bar)

3.4

3.1

2.9

2.5

2.1

1.7

1.2

0.7

Remove the pump 

assembly from the 

packaging

Insert the pump assembly 

into the tank via the top 

mounting hole

Ensure that the top plate 

is sitting correctly within 

the vibration isolating 

insulation

Read these instructions  

thoroughly before 

installing the unit

02.  ASSEMBLY