Fig. 1
4000i Generator Control Panel
The control panel for the 4000i model (Fig. 2A) is located behind the maintenance access cover and has the
following features.
1. Push button start- Push and hold for 1 second to automatically start the engine and push again
to stop.
2. Status indicator lights.
A. Low oil LED – This light indicates low oil level and will not allow the engine to start or run.
B. Overload LED – This light indicates a general system electrical overload.
C. Output ready – This light indicates the generator is ready to use.
3. ON/OFF AC Output Circuit Breaker – Allows the generator to automatically disconnect when
overloaded to protect the generator and the appliance(s). Be sure to place the circuit breaker
into the ‘ON’ position once the generator has successfully started.
4. Reset button – If the generator is overloaded, the inverter will disconnect at the AC overload
breaker. The engine will continue to run but there will be no electrical output. Reduce the
electrical loads, then push the reset button, and then turn the breaker back to ‘ON.’
5. Gasoline Primer button – Press and hold the primer button to actuate the gasoline pump to bring
fuel from the fuel tank to the generator engine. This is typically only needed the first time the
generator is operated or after returning the generator to operation after being disconnected from
13