Fault diagnosis
Page 44
9.2
Causes of faults and corrective action
Fault
Cause of fault
Corrective action
The wet separator shuts down.
Level has fallen below the minimum
fill level. Display <Low level> in
the display.
Check the fill level and if necessary top up with
suitable sealing liquid, see page 37.
Acknowledge the signal in the Display panel /
Operating panel.
Potential equalisation not plugged in or
has been disconnected. Display
<Potential equalisation lost> in the
display.
Check / establish potential equalisation, see
“Establishing potential equalisation (optional)” on
page 32.
Acknowledge the signal in the Display panel /
Operating panel.
Maximum pressure differential reached.
Display <Delta-P exceeded> in the
display.
Change filter cartridge, see page 37.
Acknowledge the signal in the Display panel /
Operating panel.
Suction power is too low.
Filter cartridges clogged.
Change filter cartridge, see page 37.
Vacuum hose blocked.
Remove blockage.
Degree of saturation of the sealing
liquid reached.
Clean the container and fill it with fresh sealing liquid.
Degasification valve does not close.
Replace the degasification valve
Bypass air valve is open or is jammed. Replace the bypass air valve.
Liquid container / moisture separator
dirty.
Clean the liquid container / moisture separator,
see page 40.
Wet separator cannot be
switched on.
Potential equalisation not plugged in or
has been disconnected.
Check / establish potential equalisation, see
“Establishing potential equalisation (optional)” on
page 32.
Level has fallen below the minimum
fill level.
Check the fill level and top up with suitable sealing
liquid, see page 37.
No suction power.
Degree of saturation of the sealing
liquid reached.
Clean the container and fill it with fresh sealing liquid.
Vacuum hose blocked.
Remove blockage.
Swirl filter / dip tube not inserted /
vacuum hose not connected.
Insert the swirl filter / dip tube. Connect the
vacuum hose.
Warning <The service interval of
the blower is nearly due>
The blower has reached a running time
of 600 hours.
Servicing of the blower is nearly due.
Warning <The service interval of
the blower is due>
The blower has reached a running time
of 700 hours.
Servicing of the wet separator is due.