The following table shows 

the discharge behavior of the 

NV 2 TC with different load.

Discharge Behavior

Status

Current in mA

Time in Hours

TC idle

40

 190

TC on subscriber line

90

 90

TC idle + 1 output (50 mA)

90

 90

TC idle + 2 outputs (50 mA each)

140

 60

TC idle + 3 outputs (50 mA each)

190

 42

TC idle + 4 outputs (50 mA each)

240

 35

TC idle + all outputs (50 mA each)

290

 29

TCR easy idle

17

 

> 200

TCR easy + relay set on

53

 160

TCR easy +TCR Z easy (1 relay set on)

88

 90

TCR easy +TCR Z easy (2 relays set on)

123

 75

TCR easy +TCR Z easy (3 relays set on)

158

 55

TCR easy +TCR Z easy (4 relays set on)

193

 40

Содержание NV 2 TC

Страница 1: ...NV 2 TC Installation instructions ...

Страница 2: ...d pieces Fix the cables at the provided bra ckets of the base plate and connect the wires For the connection of a TC and the power supply see picture 3 The terminals L1 and N are connected to the 230 V supply The ground wire is connected to terminal PE The appropriate TC is con nected with the NV 2 TC as shown in picture 3 The termi nals and are for the sup ply unit of the TC and the NA for the ou...

Страница 3: ...red to mount on the upper head piece of the housing picture 2 B The switch can be inte grated in a sabotage line of an alarm system or if desired to one of the alarm inputs of the TC Power supply Voltage Power consumption Fuse 1 Accumulator Nominal voltage Nominal capacity Dimensions l x w x h Weight Connections Battery Batteriy connection cable Fuse 2 and 3 Output terminals and Switching output N...

Страница 4: ...Figure 1 Opening and closing of the cover Figure 2 Wall mounting A A B C A A A ...

Страница 5: ...Figure 3 Connection diagram 12 V for power supply of the TC connection of output NA with an alarm input M of the TC if necessary fuse 2 2 5 A T fuse 3 2 5 A T fuse 2 2 5 A T 230 V NV 2 TC NA L1 N PE ...

Страница 6: ...e 1 output 50 mA 90 90 TC idle 2 outputs 50 mA each 140 60 TC idle 3 outputs 50 mA each 190 42 TC idle 4 outputs 50 mA each 240 35 TC idle all outputs 50 mA each 290 29 TCR easy idle 17 200 TCR easy relay set on 53 160 TCR easy TCR Z easy 1 relay set on 88 90 TCR easy TCR Z easy 2 relays set on 123 75 TCR easy TCR Z easy 3 relays set on 158 55 TCR easy TCR Z easy 4 relays set on 193 40 ...

Страница 7: ...f the malfunction with appropriate postage to Rutenbeck Service Center Gewerbegebiet Im Meilesfelde 5 99819 Marksuhl Germany Phone 49 36925 90091 Fax 49 36925 90092 We Wilhelm Rutenbeck GmbH Co KG declare on our sole responsibility that the NV 2 TC is in compliance with the essential requirements and provisions of the directives 2004 108 EG and 2006 95 EG The complete declaration of conformity can...

Страница 8: ...elm Rutenbeck GmbH Co KG 2006 Subjected to technical changes 293 997 20061201 Status 04 12 Niederworth 1 10 58579 Schalksmühle Phone 49 2355 82 0 Fax 49 2355 82 105 Germany www rutenbeck de mail rutenbeck de ...

Отзывы: