10 Settings

Factory settings

You can replace the Control 

IP 4 factory settings with your 

own settings.

Proceed as follows to restore 

the factory settings:

1.  Disconnect the Control IP 4 

from the 230 V mains  

voltage.

2.  Simultaneously press but-

tons 1 and 2 on the device 

and re-connect the mains 

voltage whilst holding the 

buttons.

3.  The LEDs for the outputs 

flash after three seconds 

and the factory settings are 

loaded.

Settings

Buttons

Operating elements

LEDs

The Control IP 4 outputs can 

be switched via the buttons 

located directly on the device, 

the installed buttons or via the 

Control IP 4 website.

1-4:

  Switches the connected 

device on/off; restores the 

factory settings (see above)

1-4:

  Switching state of the 

device (illuminated when 

switched on)

Link:

 Link state (illuminated in 

the event of a network 

connection)

Act:

  Activity (flashes when the 

Control IP 4 web interface 

is being called up)

Содержание Control IP 4

Страница 1: ...Control IP 4 Operating instructions GB Technical Support 49 2355 82 111 technical support rutenbeck de Commercial Support 49 2355 82 137 commercial support rutenbeck de ...

Страница 2: ...overview Device overview Buttons for manual switching LED for activity To the 230 V power supply Network connection Temperature sensor connection LED for link External buttons for manual switching Switch outputs ...

Страница 3: ...times can be individually selected for each switch output The Control IP 4 automatically obtains the time required for the switch functions from the europe pool info org server using the Simple Network Time Protocol SNTP and providing that the server can be reached is then compared each hour The current temperature can be displayed providing that a tem perature sensor is connected the network prop...

Страница 4: ...y only be per formed by authorised electricians Risk to life from electric current Ensure that the power supply is disconnected before performing any assembly work Please observe the permissible operating temperature do not use the Control IP 4 directly next to devices that generate a high amount of heat e g dimmer Ensure that the device is only used indoors Installation Installation Notice ...

Страница 5: ...Settings 5 Network settings without DHCP server Settings Figure 1 F A B C D E ...

Страница 6: ...voltage 4 The Control IP 4 can now be accessed via the address http 192 168 0 3 or http TCRIP4 factory setting 5 Select the Network menu in the menu bar Fig 1 A 6 Select an individual Net work name in order to be able to call up the Control IP 4 directly 7 Modify the IP address of the Control IP 4 to suit your own needs 8 The configuration is stored by pressing Save Network settings without DHCP s...

Страница 7: ...30 V mains voltage 4 The Control IP 4 can now be accessed via the address http 192 168 0 3 or http TCRIP4 factory setting 5 Select the Network menu in the menu bar Fig 1 A 6 Select an individual Net work name in order to be able to call up the Control IP 4 directly 7 Now activate the DHCP client Fig 1 B 8 A free IP address is now assigned to the Control IP 4 Network settings with DHCP server Setti...

Страница 8: ...8 Settings Configuration Settings H I Figure 2 G ...

Страница 9: ...e website is able to switch manually and oper ate the timer switch Only the admin is able to per form network settings and configuration 3 Administrator name and User name user and admin have access to the website and are able to switch manually However the network settings the timer switch settings and the configuration can only be performed by admin You can give the four outputs individual names...

Страница 10: ... the outputs flash after three seconds and the factory settings are loaded Settings Buttons Operating elements LEDs The Control IP 4 outputs can be switched via the buttons located directly on the device the installed buttons or via the Control IP 4 website 1 4 Switches the connected device on off restores the factory settings see above 1 4 Switching state of the device illuminated when switched o...

Страница 11: ...Switching 11 Impuls mode Switching Figure 3 K J ...

Страница 12: ... switches the output off The impulse period commences when the Send field is clicked The time at which the Impulse activated notification is con firmed with OK has no effect on the impulse period The output is switched off once the period has elapsed The Control IP 4 acts converse ly when an out impulse is sent when the output is switched off The current state of the respec tive output is displaye...

Страница 13: ...Switching 13 Time switch function Switching Figure 4 ...

Страница 14: ...from Monday to Friday One off switching processes can also be applied for set dates The company s lighting for the stairs is connected to switch output 2 The court lighting is connected to switch output 3 The user can also switch the lighting on outside of the stipu lated times by using the buttons or via the website Fig 4 H Where necessary the output can also be put into impulse mode as described...

Страница 15: ...is saved in the Control IP 4 by pressing the Save system time button It is updated and is accurate to one second In order to prevent unnecessary network load the Control IP 4 time is only updated on the screen display every 30 sec onds The internal clock of the ICP IP 4 will continue to run for approx four days after being discon nected from the mains Time switch function Switching ...

Страница 16: ...ion Outputs off network off Outputs on network on Timer Power reserve Power deviation Technical data 72 x 90 x 65 mm PC 210 g Light grey similar to RAL 7035 IP20 according to DIN EN 60529 20 to 55 C 25 to 70 C 100 240 V AC 50 60 Hz max 230 V AC 50 60 Hz 10 A ohmic load cos ϕ 1 max 230 V AC 50 60 Hz 7 A inductive load cos ϕ 0 4 approx 1 W approx 3 5 W approx 4 days following disconnection from the ...

Страница 17: ...ength Extension Temperature range Temperature range 25 C 25 C 50 C B value RJ45 10 Mbit s 700 802 201 0 6 m to a maximum of 10 m 25 to 55 C resolution 1 C 86 4 kΩ 10 kΩ 4 1 kΩ 3 435 K 1 Technical data Control IP 4 700 802 610 Operating instructions 293 656_GB Temperature sensor 700 802 201 Scope of delivery Accessories optional ...

Страница 18: ...directives 2014 30 EU 2014 35 EU 2011 65 EU The complete Declaration of Conformity is available in the Download Section at www rutenbeck com The adjacent symbol indicates separate waste collection for electrical and elec tronic devices In accordance with EU directives all electrical and electronic de vices with this symbol must be disposed in the corresponding separate waste collections and not in...

Страница 19: ...Notices 19 Notices ...

Страница 20: ...3 58579 Schalksmühle Germany Phone 49 0 23 55 82 0 Fax 49 0 23 55 82 105 www rutenbeck de mail rutenbeck de Wilhelm Rutenbeck GmbH Co KG 293 656_GB 700 802 610 Rut047 Stand 04 19 Subject to technical modifications ...

Отзывы: