![Rustibus X1200 AIR Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/rustibus/x1200-air/x1200-air_operation-manual_1502987015.webp)
Rustibus® X1200 AiR VERsiON
before use, the Lubricator (120-3010-1) must be filled with air tool oil.
Disconnect the air pressure!
to fill, remove the lower section of the Lubricator by pressing in the black button on the side of the lubri-
cator and turning it to one side, until it becomes free.
Fill the lubricator housing up to 75% full.
Replace the lubricator by setting in place and turning until the black button on the side, ‘clicks’ into place.
the lubricator should be set to approx. 10 drops of oil pr. min.
(Adjustment screw is located on top of the lubricator)
When using the machine make sure that the lubricator is always filled with air tool oil.
Refill when necessary.
the air filter will separate water from the pressured air and collect water in filter tank. the water must be
drained from the air filter tank when required. Empty the tank by pushing the knob sideways at the tank
bottom.
if the oil tank/air filter is to be dismantled, unscrew the black cover in front of the lubricator/air filter
before being able to remove the tank.
When the
Rustibus®
X1200 Air is stowed away after use, it should be filled with 0,1 litres of lube oil to
ensure functionality upon next time of use. see spare part drawing for further details.
CAUTION!
Disconnect the air pressure supply hose when maintenance or service is to be carried out on the
machine.
• All maintenance on the machine/tool should be carried out in an area/environment that is safe /free
from potentially explosive oils, acids, gases, vapors or radiation. Only conduct maintenance on your
machine in an area that is safe to do so.
Genuine Rustibus® parts only!
Machine may vary from pictures