Russound COMPOINT - Скачать руководство пользователя страница 30

30

INSTALLER SECTION

System Functions

Pressing the Call key also causes the doorbell
contacts to close for a minimum of 4 seconds
to activate a separate doorbell or other device
connected to the door station. The actual time
varies with the doorbell selection on hub 1; the
contacts remain closed for the duration of the
selected chime.

Also, all keypads indicate which door station is
calling, regardless of whether or not they’re in
DND mode. The indication remains for 15 sec-
onds, during which the door station is selected
at each keypad for reply.

Within the 15 seconds, a person at any keypad
can then speak with the person at the door
while holding in the Talk key. If the 15 seconds
pass before the Talk key is pressed, the person
inside will need to first select the door station
on the keypad and then press the Talk key to
start a new session. This will not activate the
doorbell chime.

When a door call is answered from inside, the
release of the Talk key at the keypad triggers a
single ping at the door station to let the caller
know they can reply. The person at the door
station has a 7-second window for a hands-free
reply after the single ping. The caller has the
option of speaking within the 7 seconds or
pressing and holding the Call key to speak
longer. Holding in the Call key keeps the audio
bus switched to the door station’s microphone.

If the 7-second hands-free window ends before
the caller presses the Call key to speak, the
door station sounds a double ping indicating the
audio bus has opened. At this point the caller
must press the Call key again to request anoth-
er session if they wish to speak longer. This
also rings the doorbell again.

Door strike release

The optional ISDR1 Door Strike Release module
can be activated from any keypad at any time.
When activated, the module stays active for 3
seconds, confirmed by a buzz tone at the key-
pad and the door station.

On an ISK1 Basic Keypad, the module is activat-
ed by pressing and holding the appropriate door
key for 3 seconds.

When a communication session is active
between a door station and an ISK2 Advanced
Keypad, the module can be activated by press-
ing and holding both the Previous and Next keys
for 3 seconds. If no session is active, the door
will first need to be selected on the keypad.

Listen mode

Listen mode is a system state in which one key-
pad has a constantly active microphone and
one or more other keypads are receiving its
audio signal. This mode is subject to temporary
interruption when the system is used for pag-
ing, intercom, or door station sessions.

Selecting a keypad’s own zone connects its
microphone to the audio bus 2 seconds after
the selection is made. That zone then becomes
the sending zone for Listen mode. The keypad’s
Talk key lights up red to indicate the micro-
phone is on. In addition, the zone key on an
ISK1 Basic Keypad blinks red and the display on
an ISK2 Advanced Keypad shows 

MicOn

.

If another zone is already selected as a sending
zone for Listen mode, the keys on the Basic
Keypad for both the active zone and the desired
zone alternately blink red for 7 seconds to indi-
cate which zone’s microphone is active. The
Advanced Keypad alternately displays the active
zone and 

MicOn

for 7 seconds.

Door station call 

(cont’d)

Содержание COMPOINT -

Страница 1: ...ComPoint The music lover s intercom solution Instruction Manual...

Страница 2: ...nt of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience recep tacles and the point where it exits from the apparatus 11 Use only attachmen...

Страница 3: ...ng and connections 19 21 110 punch down connections 19 Speaker connections 20 Hub modular connections 20 Doorbell connections 20 Door strike release connections 21 Programming 21 27 Overview 21 Doorbe...

Страница 4: ...the nearest keypad Point to point intercom One of ComPoint s most useful functions is the intercom feature You need to talk with someone in another room out of earshot and you can t leave the room yo...

Страница 5: ...the delivery person rings your doorbell they can answer your reply without having to press the Call key again Integration with your music system For even greater convenience your ComPoint system can s...

Страница 6: ...ut volume PREVIOUS KEY Scrolls backward through lists and installer menus also activates door release with Next key Advanced Keypad only 6 1 2 3 4 5 7 8 9 1 2 3 1 2 3 MICROPHONE AND SPEAKER Enable two...

Страница 7: ...m Components ISH1 Hub As the heart of the system the hub keeps track of the zones and routes communications appropriately It also provides your choice of chime sounds for the built in doorbell feature...

Страница 8: ...room without multiroom audio system speakers It can also be used in every room when ComPoint is used as a stand alone system ISDR1 Door Strike Release Module ISSP ComPoint Speaker USER SECTION System...

Страница 9: ...tion call or page in progress Paging and intercom interrupt Listen mode Your ComPoint system is configured with either ISK1 Basic or ISK2 Advanced key pads The way you use your system and the way it g...

Страница 10: ...ly to the page after the 30 second limit you can use the intercom function described below or a return page to send your reply Intercom Unlike a system wide page an intercom session occurs only betwee...

Страница 11: ...e you speak After 30 seconds you can no longer reply but you can start another intercom session to the zone that sent the original message Door station call A visitor can ring the doorbell and start a...

Страница 12: ...r has 7 seconds to answer your reply hands free After 7 seconds the door station pings twice to indicate the time is up If more than 15 seconds have passed since the door call you can reselect the doo...

Страница 13: ...To do this first turn on a keypad microphone in the zone you want to listen to then select that zone on one or more other keypads Other communication events have priority over Listen mode but only te...

Страница 14: ...the zone you are listening to on the keypad in that zone Listen mode cannot be canceled from any other zone Do Not Disturb mode The Do Not Disturb DND feature allows you to prevent pages intercom ses...

Страница 15: ...ypad Then turn on DND The Talk key and DND key light up red to indicate the keypad s microphone is on and the zone is also in DND mode On a Basic Keypad the zone key also blinks On an Advanced Keypad...

Страница 16: ...nveys power ground audio and data between the components The cable length limit for any zone or door station is 250 feet 76 m The system can include one or two door sta tions connected to hub 1 Each d...

Страница 17: ...iers for commu nications By using built in speaker relays the keypads can share the speakers used in a multi room audio system When ComPoint activates the relays switch the speakers from the audio sys...

Страница 18: ...These close for a mini mum of 4 seconds to activate an existing door bell or other device ISDR1 Door Strike Release Module The optional ISDR1 Door Strike Release Module provides relay contacts for act...

Страница 19: ...b The ISDR1 connects to a door strike release unit which in most cases would be installed by a security contractor Wiring and connections ComPoint system components connect with CAT 5 cable Run CAT 5...

Страница 20: ...rd color code for 4 conductor speaker cable is as follows Wire Color Polarity White Left Green Left Black Right Red Right Hub modular connections The hub has 8 pole modular jacks for keypad and door s...

Страница 21: ...x zone system with ISK1 Basic Keypads programming consists only of setting the doorbell chimes For a system with ISK2 Advanced Keypads programming includes assigning zone and door station labels For a...

Страница 22: ...nnect only to hub 1 Because the settings take effect immediately the door bell chimes can be set at any time There is no need to cycle the power after setting them Hub ID numbers In any ComPoint syste...

Страница 23: ...ate Gate Grage Garage SDoor Side Door SvcDr Service Door INSTALLER SECTION Programming Assignable zone labels for ISK2 Advanced Keypads Zone Label Room Name Zone Label Room Name Zone Label Room Name A...

Страница 24: ...e the selec tion The display shows Zn to prompt you to select the next zone 7 Repeat steps 3 through 6 for the remaining zones Press and release the Setup button to exit the procedure You can then go...

Страница 25: ...firmware version To view system information follow these steps or the System Info Menu flow chart on page 27 1 Press and release the Setup button on the right edge of the keypad to enter the main menu...

Страница 26: ...right edge of keypad behind cover plate DOOR NAME SYSTEM INFO FACTORY INIT Zn Name Press and release Setup button Main Menu ISK2 Keypad Door Name Procedure Setup button on right edge of keypad behind...

Страница 27: ...p one level Next Previous item Select parameter Enter This procedure returns the system to its factory settings Cycle Power No Yes ZONE NAME DOOR NAME SYSTEM INFO FACTORY INIT Press and release Setup...

Страница 28: ...a zone in that mode Paging Paging is the default system function To send a page all one needs to do is press and hold the Talk key and speak as long as the keypad is not indicating a selected zone or...

Страница 29: ...he sending keypad is released both the sending and target keypads sound a single ping and the target keypad permits a hands free reply by activating its microphone for 7 sec onds During this period th...

Страница 30: ...this point the caller must press the Call key again to request anoth er session if they wish to speak longer This also rings the doorbell again Door strike release The optional ISDR1 Door Strike Rele...

Страница 31: ...ounds System busy If someone attempts to start a page or inter com session when the system is busy the Talk key on the keypad blinks red for 7 seconds to indicate the system is unavailable The ISK2 Ad...

Страница 32: ...cted Reply to door station call Verify reply is heard at door station Answer reply from door station Verify hands free operation within 7 seconds Verify operation with Call key after 7 seconds Verify...

Страница 33: ...minations Keypad failed to register with hub other keypads don t indicate this keypad s zone Open communication wire in CAT 5 cable or bad termination Check blue pair and terminations Keypad was conne...

Страница 34: ...x 4 188 H x 2 625 D 4 8 x 10 6 x 6 7 cm Weight 5 6 oz 159 g ISK3 Door Station User control Call key with amber backlight Audio input Built in microphone with automatic gain control Amplifier Monaural...

Страница 35: ...e power voids the warranty In these cases the repair will be made at the owner s expense To return a product for repairs the unit must be shipped to Russound at the owner s expense along with a note e...

Страница 36: ...tech russound com ComPoint The music lover s intercom solution Instruction Manual Models ISH1 ISK1 ISK2 ISK3 ISDR1 ISSP Copyright 2006 Russound All rights reserved All trademarks are the property of...

Отзывы: