Russound CA 4.4i Скачать руководство пользователя страница 7

7

ZONE PRE-AMP OUTPUTS

Switch in VARIABLE Position: 

In applications

where more power than the 20 watts per chan-
nel is desired, connect one or more zones of the
CAi to an external amplifier. Using standard

RCA connectors, wire from the pre-amp outputs of the CAi to
the amplifier's inputs. A typical application for more power is
when connecting an outside zone where the audio power
requirements would be much greater than an inside zone.

Figure 5a

- Variable Output Connection

Switch in FIXED Position:

When adding sub-

zones, connect an amplifier or A-BUS Hub to
the RCA connection. When the switch is in the
FIXED position, the audio level will not be var-

ied by the keypad volume for the zone.

Figure 5b

- Fixed Output 

Connection

12-VOLT TRIGGER OUTPUT

The 12 volt trigger is engaged when any of the zones are on
and disengaged when the last zone is turned off. The trigger
can be used to engage any 12 volt triggered accessory, such
as a triggered AC outlet or audio amplifier. The connection
for the trigger is made through an 1/8” male mini-plug jack.
The tip is (+) and sleeve is (-).

Figure 6

- 12-Volt Trigger Output Connection

MUTE

When used with the optional Doorbell or
Telephone interface, the Mute Input
mutes the audio to the speakers, the
doorbell is used or when the telephone

rings. The connection for the Mute Input is made through a
1/8” male mini-plug. The tip is (+) and the sleeve is (-),
12VDC.

When more than one CAi is used, connect the MUTE OUT of
the first CAi to the MUTE IN of the second CAi.

Figure 7

- DIM-1 Doorbell Interface Module

CONNECTING THE INFRARED COMPONENTS

• In order for your CAi to transmit the IR signal from the

keypads to a source, an emitter must be connected from
the IR outputs marked 1-4. All IR outputs are common

• Connect each 845.1 mini-emitter to the IR output.

• Remove the adhesive back and position the IR receiver on

the product you wish to control. Stick the 845.1 emitter
directly over the source components IR window.

Figure 8 

- IR Emitter Connections

CONNECTING THE (IR) LINK

When two or more CAi Controllers are to be used in an
installation, the LINK connection is used to pass IR signal
between the two units. Use an 1/8” mini-plug, male-to-male
cable (included) connected from the LINK OUT on the first
CAi Controller to the LINK IN on the second CAi. When con-
nected, you may connect your IR emitters to either CAi unit’s
IR EMITTERS jacks.

R

EAR

P

ANEL

C

ONNECTIONS

1

R

L

2

Z

ONE 

P

REAMP 

O

UTPUTS

VARIABLE

FIXED

VARIABLE

FIXED

VARIABLE

FIXED

VARIABLE

FIXED

1

2

3

4

L

IR E

MITTERS

IR

 

C

ONFIRM

DESIGNED IN USA    MADE IN KOREA

P

OWER

24VDC 4A

S

TATUS

12VDC 100mA

NEWMARKET, NH U.S.A.

R

A-H2

2-Z

ONE

, 1-S

OURCE 

S

URFACE 

M

OUNT 

A

UDIO 

H

UB

A

UDIO

I

N

1

2

K

EYPAD 

O

UTPUTS

E

XPANSION

I

NPUT

B

YPASS

S

TATUS

1

R

L

2

Z

ONE 

P

REAMP 

O

UTPUTS

VARIABLE

FIXED

VARIABLE

FIXED

R

L

LINK

IN

OUT

Rear of CAi unit

IR Link Cable

IR Emitter Out

IR Link In

A-BUS Hub

MUTE

IN

OUT

ACT-1

CAi-Series manual  10/17/02  11:01 AM  Page 7

Содержание CA 4.4i

Страница 1: ...ler Amplifier 1 2 3 4 5 6 ZONE REMOTE SENSOR ON OFF VOLUME SOURCE R B CHILDRENS ROCK JAZZ REMOTE SENSOR VOLUME SOURCE STORE POWER CA4 4i 4 Zone 4 Source Central Controller Amplifier POWER 1 2 3 4 ZONE...

Страница 2: ...ces The appliance should be connected to a power supply only of the type described in the operating instructions or as marked on the appliance 11 Grounding or Polarization The precautions that should...

Страница 3: ...nnecting the Infrared Components 7 Connecting the IR Link 7 Keypad Connections at Controller 8 Wiring at the Controller 8 Clean Installations 8 Installing Keypads 9 Punchdown Terminals 9 Installing th...

Страница 4: ...bility and Quality are the primary objectives Russound products are guar anteed to provide years of enjoyment The CAi conforms to UL and CSA safety specifications POSSIBLE SYSTEM CONFIGURATIONS PRODUC...

Страница 5: ...onnectors If you have problems or you are not absolutely comfortable with what you are doing consult a professional carpenter electrician or system installer BASIC PLANNING AND LAYOUT CONSIDERATIONS W...

Страница 6: ...______ Zone 3 ________________ Zone 4 ________________ REAR PANEL CONNECTIONS 1 R L 2 1 R L 2 3 4 CA6 4i NEWMARKET NH U S A 110VAC 220 240VAC 50 60Hz 400W VOLTAGE 110V 220 240V FUSE F4A F2A KEYPAD POR...

Страница 7: ...gh a 1 8 male mini plug The tip is and the sleeve is 12VDC When more than one CAi is used connect the MUTE OUT of the first CAi to the MUTE IN of the second CAi Figure 7 DIM 1 Doorbell Interface Modul...

Страница 8: ...s from the Wall Plate KEYPAD CONNECTIONS AT CONTROLLER KEYPAD PORTS 1 2 3 4 1 2 3 4 5 6 7 8 CAT 5 Cable RJ 45 using T568A Wiring Standard Each keypad connection on the back panel of the CAi Series Mas...

Страница 9: ...and saw If you are installing the optional DSC keypad you will need to use a double gang electrical box If you are installing both the optional DSC and DAN keypad you will need to install a triple gan...

Страница 10: ...grammer is compatible with DAN and DSC IR Keypads which have a 5 pin programming port located at the top left of the keypad Refer to IKP 1 Instruction Manual for complete instructions 1 Loads IR code...

Страница 11: ...using the optional SRM 2 1 speaker relay module wire the terminals of the CA LCD2 to the SRM 2 1 terminals Figure 16 SRM 2 1 connection to CA LCD2 Refer to the SRM 2 1 Instruction Manual for complete...

Страница 12: ...on the keypad will also illuminate to verify the zone is now on Note The CAi front panel zone management lights also informs you which zones are On or Off 2 Volume Up Down Once the unit is on the kno...

Страница 13: ...ne of the 23 preset source names for each of the four sources Select the source name that you want to change by selecting source Press and hold the store button for approximately 3 seconds and the dis...

Страница 14: ...device may have been activated Please take the following steps to troubleshoot the system 1 Turn off the power switch on the front of the CAi Series controller 2 Disconnect all keypad connections fro...

Страница 15: ...n transit TROUBLESHOOTING WARRANTY COMBINING ADDITIONAL IR RECEIVERS When combining a CAi Series multi source controller and a secondary IR system together it needs to be done after the CAi System The...

Страница 16: ...A V D I S T R I B U T I O N C O N T R O L S Y S T E M S 5 Forbes Rd Newmarket NH 03857 603 659 5170 Fax 603 659 5388 e mail tech russound com Come visit us at 28 0106...

Отзывы: